• 제목/요약/키워드: Unit-Water

검색결과 2,771건 처리시간 0.029초

낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석 (Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin)

  • 이홍신;손건태;구정은;콘분락사;이홍태;이승환
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

수질오염총량관리를 위한 4대강수계 장기유황곡선 작성방안 (Development of Long Term Flow Duration Curves in 4 River Basins for the Management of Total Maximum Daily Loads)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.343-353
    • /
    • 2013
  • Flow duration curve (FDC) can be developed by linking the daily flow data of stream flow monitoring network to 8-day interval flow data of the unit watersheds for the management of Total Maximum Daily Loads. This study investigated the applicable method for the development of long term FDC with the selection of the stream flow reference sites, and suggested the development of the FDC in 4 river basins. Out of 142 unit watersheds in 4 river basins, 107 unit watersheds were shown to estimate daily flow data for the unit watersheds from 2006 to 2010. Short term FDC could be developed in 64 unit watersheds (45%) and long term FDC in 43 unit watersheds (30%), while other 35 unit watersheds (25%) were revealed to have difficulties in the development of FDC itself. Limits in the development of the long term FDC includes no stream monitoring sites in certain unit watersheds, short duration of stream flow data set and missing data by abnormal water level measurements on the stream flow monitoring sites. To improve these limits, it is necessary to install new monitoring sites in the required areas, to keep up continuous monitoring and make normal water level observations on the stream flow monitoring sites, and to build up a special management system to enhance data reliability. The development of long term FDC for the unit watersheds can be established appropriately with the normal and durable measurement on the selected reference sites in the stream flow monitoring network.

고주파수분센서를 이용한 골재 종류에 따른 콘크리트 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Concrete Unit-Water Content by Aggregate Type Using Frequency Domain Reflectometry Sensor)

  • 윤지원;이승엽;유승환;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.201-202
    • /
    • 2023
  • Recently, interest in concrete quality has been increasing. It is important to manage these factors due to unit-water content and aggregate quality that affect concrete quality. In this study, the unit-water content of concrete was measured through an economical, easy-to-measure, and portable Frequency Domain Reflecmetry sensor among micro-methods that compensated for the shortcomings of existing concrete unit-water content measurement methods. As a result of predicting the unit-water content, the accuracy within the ± 10 kg/m3 error range was confirmed to be more than 72% of all factors. In order to ensure high accuracy, it is considered necessary to conduct an experiment to evaluate the unit-water content by conducting additional experiments according to other variables and factors.

  • PDF

농업용 저수지에서의 농업용수 잠재능 평가 (Evaluation of Agricultural Water Supply Potential in Agricultural Reservoirs)

  • 김진수;이재용;이정범;송철민;박지성
    • 한국농공학회논문집
    • /
    • 제58권2호
    • /
    • pp.65-71
    • /
    • 2016
  • The new concept of agricultural water supply potential, which is mean annual turnover rate times unit storage capacity, was introduced for agricultural reservoirs. We investigated characteristics of mean annual turnover rate and unit storage capacity for agricultural reservoirs with storage capacity of over $1million\;m^3$. The curve of agricultural water supply potential represents change in mean annul turnover rate according to change in unit storage capacity. The mean annual turnover rate and unit storage capacity in the reservoirs with high minimum storage ratio are significantly higher than those in the reservoirs with low minimum storage ratio. Most of unstable water supply reservoirs showed low mean annual turnover rate or low unit storage capacity, indicating that mean annual turnover rate may be an index of stability degree for agricultural water use. The reservoirs with mean annual turnover rate of over 2 and unit storage capacity of over 0.8 m may be estimated as the stable water supply zone for 10 frequency dry year. The reservoirs with high agricultural water supply potential can belong to the wide range of stable water supply zone. The results suggest that relation between mean annual turnover rate and unit storage capacity may be used in evaluating stability degree for agricultural water supply in the reservoirs.

Water Footprint 개념을 이용한 가전제품의 수자원 사용량 산정 (세탁기를 중심으로) (A Study on the Evaluation of Water Consumption in Electric Appliances using Water Footprint - Focusing on Washing Machine -)

  • 조현정;김우람;박지형;황용우
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.691-697
    • /
    • 2011
  • In this study, by using the Water footprint technique, the water consumption by washing machines, which holds higher ranks in using water than any other electric appliances, was analyzed during their life cycle. The life cycle is defined as raw materials production step, manufacturing step, and using step. In raw materials production step, Input materials were researched by using LCI DB(Life Cycle Inventory Database) and the water consumption was calculated with consideration of approximately 65% Input materials which were based weight. In manufacturing step, the water consumption was calculated by the amount of energy used in assembly factories and components subcontractors and emission factor of energy. In using step, referring to guidelines on carbon footprint labeling, the life cycle is applied as 5 years for a washing machine and 218 cycles for annual bounds of usage. The water and power consumption for operating was calculated by referring to posted materials on the manufacture's websites. The water consumption by nation unit was calculated with the result of water consumption by a unit of washing machine. As a result, it shows that water consumption per life cycle s 110,105 kg/unit. The water consumption of each step is 90,495 kg/unit for using, 18,603 kg for raw materials production and 1,006 kg/unit for manufacturing, which apparently shows that the using step consume the most water resource. The water consumption by nation unit is 371,269,584tons in total based on 2006, 83,385,649 tons in both steps of raw material production and manufacturing, and 287,883,935 tons in using step.

고해상도 기후시나리오를 이용한 논용수 수요량 및 단위용수량의 기후변화 영향 분석 (The Impacts of Climate Change on Paddy Water Demand and Unit Duty of Water using High-Resolution Climate Scenarios)

  • 유승환;최진용;이상현;오윤경;박나영
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.15-26
    • /
    • 2012
  • For stable and sustainable crop production, understanding the effects of climate changes on agricultural water resources is necessary to minimize the negative effects which might occur due to shifting weather conditions. Although various studies have been carried out in Korea concerning changes in evapotranspiration and irrigation water requirement, the findings are still difficult to utilize fordesigning the demand and unit duty of water, which are the design criteria of irrigation systems. In this study, the impact analysis of climate changes on the paddy water demand and unit duty of water was analyzed based on the high resolution climate change scenarios (specifically under the A1B scenario) provided by the Korea Meteorological Administration. The result of the study indicated that average changes in the paddy water demand in eight irrigation districts were estimated as -2.4 % (2025s), -0.2 % (2055s), and 3.2 % (2085s). The unit duty of water was estimated to increase on an average within 2 % during paddy transplanting season and within 5 % during growing season after transplanting. This result could be utilized for irrigation system design, agricultural water resource development, and rice paddy cultivation policy-making in South Korea.

수질오염총량관리 단위유역의 유량변화 특성분석 - 금강수계를 대상으로 - (Characterization on the Variation of Streamflow at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin -)

  • 박준대;오승영;최옥연
    • 한국물환경학회지
    • /
    • 제27권6호
    • /
    • pp.914-925
    • /
    • 2011
  • The variation of streamflow is regarded as one of the most influential factors on the fluctuation of water quality in the stream. The characteristics of the variation should be taken into account in the plans for the management of Total Maximum Daily Loads (TMDLs). This study analysed and characterized spatial distribution and temporal variation of streamflow at each unit watershed in Guem-river basin. For the analysis of the distribution of streamflow, the type and the extent of the distribution were investigated for the unit watershed. For the analysis of the variation, short and long term changes of streamflow were examined. The result showed that most of the distributions were not log-normalized and the extent of variation tends to be greater at the unit watershed placed on the tributaries in the basin. A kind of margin could be granted to the unit watershed involving high variations so as to establish the water quality goal and load allotment more reasonably and effectively in view of whole waterbody.

양식계 오염원 배출량 산정을 위한 원단위 설정 (Evaluation of Pollutant Load Unit Factor for Calculating Pollutants Emission in Aquacultural Farms)

  • 박재홍;박배경;류덕희;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.656-665
    • /
    • 2013
  • This research was conducted to investigate pollutant load unit factor from aquacultural farms. Pollutant load unit factors were investigated on the 13 kinds of fish type, i.e., Trout, Leather Carp, Eel, Carp, Cartfish, Freshwater Eel, Crucian Carp, Colored Carp, Sturgeon, Marsh Snail, Sweetfish, Pond Snail, Eriocheir Sinensis. Water qualities in aquacultural farms were investigated wide range of values by fish type and pollutant items. High BOD and COD values were observed at the Leather Carp (Ponded water system), Cartfish (Ponded water system) and Freshwater Eel (Recirculating System). TOC and DOC values were relatively high at the Freshwater Eel (Recirculating System) and Eriocheir Sinensis (Extensive). Eel (Ponded water system) and Freshwater Eel (Recirculating System) produced high concentrated nutrient pollutants, i.e., T-N, T-P. Pollutant load unit factors are dependent on fish type, aquacultural type, water quality items, etc. If some fishes have similar basic unit values, those could be applied for TMDLs as a group of fish having same pollutant load unit. The water quality concentrations of post treatment facilities' (mainly reservoir tank) effluent were higher than those of fish raising bath because of extracting pollutant from sediment in the reservoir tank. Therefore, it needs to the management and regulations about post treatment facilities.

비모수 경향분석법 적용을 통한 금강수계 총량관리 단위유역의 수질변화 연구 (A Study on the Water Quality Changes of TMDL Unit Watershed in Guem River Basin Using a Nonparametric Trend Analysis)

  • 김은정;김용석;류덕희;류지철;박배경
    • 한국물환경학회지
    • /
    • 제30권2호
    • /
    • pp.148-158
    • /
    • 2014
  • In order to assess the effect of TMDLs management and improve that in the future, it is necessary to analyze long-term changes in water quality during management period. Therefore, long term trend analysis of BOD was performed on thirty monitoring stations in Geum River TMDL unit watersheds. Nonparametric trend analysis method was used for analysis as the water quality data are generally not in normal distribution. The monthly median values of BOD during 2004~2010 were analyzed by Seasonal Mann-Kendall test and LOWESS(LOcally WEighted Scatter plot Smoother). And the effect of Total Maximum Daily Loads(TMDLs) management on water quality changes at each unit watershed was analyzed with the result of trend analysis. The Seasonal Mann-Kendall test results showed that BOD concentrations had the downward trend at 10 unit watersheds, upward trend at 4 unit watersheds and no significant trend at 16 unit watersheds. And the LOWESS analysis showed that BOD concentration began to decrease after mid-2009 at almost all of unit watersheds having no trend in implementation plan watershed. It was estimated that TMDLs improved water quality in Geum River water system and the improvement of water quality was made mainly in implementation plan unit watershed and tributaries.

덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구 (A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER)

  • 이병문;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF