• Title/Summary/Keyword: Unit under test

Search Result 480, Processing Time 0.022 seconds

A Unit Root Test via a Discrete Cosine Transform (이산코사인변환을 이용한 단위근 검정)

  • Lee, Go-Un;Yeo, In-Kwon
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • In this paper, we introduce a unit root test via discrete cosine transform in the AR(1) process. We first investigate the statistical properties of DCT coefficients under the stationary AR(1) process and the random walk process in order to verify the validity of the proposed method. A bootstrapping approach is proposed to induce the distribution of the test statistic under the unit root. We performed simulation studies for comparing the powers of the Dickey-Fuller test and the proposed test.

Durbin-Watson Type Unit Root Test Statistics

  • Kim, Byung-Soo;Cho, Sin-Sup
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.1
    • /
    • pp.57-66
    • /
    • 1998
  • In the analysis of time series it is an important issue to determine whether a time series under study is stationary. For the test of the stationary of the time series the Dickey-Fuller (DF) type tests have been mainly used. In this paper, we consider the regular unit root tests and seasonal unit root tests based on the generalized Durbin-Watson (DW) statistics when the errors are independent. The limiting distributions of the proposed DW-type test statistics are the functionals of standard Brownian motions. We also obtain the finite distributions and powers of the DW-type test statistics and compare the performances with the DF-type tests. It is observed that the DW-type test statistics have good behaviors against the DF-type test statistics especially in the nonzero (seasonal) mean model.

  • PDF

Design and Application of Accelerated Run-in Test for ECU Quality Improvement (ECU 품질 개선을 위한 Accelerated Run-in Test 설계 및 효과고찰)

  • Cho, Hyogeun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.145-151
    • /
    • 2014
  • Modern vehicle has a lot of ECU(Electronic Control Unit) products to control many parts such as engine, transmission, brake, body and so on. ECU quality is one of important factors related to vehicle quality and driver's safety. Based on Bath-tub curve which presents failure rate during product lifetime, we designed and applied Accelerated Run-in Test into manufacturing line by simulating stress amount to ECU and developing the required software and efficient test equipment for mass production. This test makes ECU products stressed through electrical and thermal stresses under excessive driving condition, which induce potential initial failure of components in the ECU during production. The outcome until these days proved that Acceleration Run-in Test have reduced initial failure rates and increased quality of ECU products in the field outstandingly.

A Unit Root Test Based on Bootstrapping

  • Shin, Key-Il;Kang, Hee-Jeong
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.1
    • /
    • pp.257-265
    • /
    • 1996
  • We consider nonstationary autoregressive autoregressive process with infinite variance of error. In the case of infinite cariance, the limiting distribution of the estimated coefficient is different from that under the finite cariance assumption. In this paper we show that the bootstrap method can be used to approximate the distribution of ordinary least squares estimator of the coefficient in the first order random walk process with infinite variance through some empirical studies and we suggest a test procedure based on bootstrap method for the unit root test.

  • PDF

A study on impact collapse characteristics of CFRP thin-walled laminates under high temperatures and hygrothermals (고온 고습하에서 CFRP 적층 원통부재의 충격 압궤특성)

  • 김정호;곽훈이;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.30-38
    • /
    • 1998
  • In this study, in order to measure energy-absorbing characteristics in impact test of CFRP thin-walled laminates and interpret the cause of decreasing age when collapse test is carried out under the environments of high temperatures and hygrothermals, the moisture absorbing behavior according to the variety of orientation angle is observed and impact collapse characteristics of no moisture absorbing status is compared with that under the environments of high temperatures and hygrothermals. Especially, we try to obtain quantitative design data to develop CFRP thin-walled laminates with energy characteristics of optimum impact absorbing. The value of the maximum loading, mean loading, rate of energy absorption energy per unit volume and mass in CFRP thin-walled laminates on the high temperatures and hygrothermals is measured much lower than under no moisture absorbing. The maximum collapse loading in dynamic impact test is taken measurements lower than in static collapse test CFRP circular laminates in high temperatures and hygrothermals. But the absorbed energy per unit mass and volume is almost same each other and the biggest amount of energy is shown in CFRP circular laminates with orientation angle of $15^{\circ}$. Therefore, in the case of using CFRP circular laminates with axisymmetric mode, CFRP thin-walled structural members with orientation angle of $10^{\circ}$, $15^{\circ}$ has generally best condition.

  • PDF

Structure Analysis and Loading Test of Torque arm for Driving Gear Unit of Unique Model (독자모델 감속구동장치 토크암의 구조해석 및 하중시험에 관한 연구)

  • Cha Soo-Deok;Choi Jin-Wook;Yu Jai-Il;Lee Min-Soo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.211-215
    • /
    • 2004
  • This paper describes the result of structure analysis and load test of torque arm for driving gear unit. The purpose of the analysis and test is to evaluate an safety which torque arm shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Driving gear unit consist of gearbox and torque arm. Both components, torque arm is significant component subjected to the vehicle and motor loads. The evaluation methode is used the FEM analysis, static and fatigue test. The test results have been very safety and stable for design load conditions.

  • PDF

Robust Unit Root Tests with an Innovation Variance Break

  • Oh, Yu-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.1
    • /
    • pp.177-182
    • /
    • 2012
  • A structural break in the level as well as in the innovation variance has often been exhibited in economic time series. In this paper we propose robust unit root tests based on a sign-type test statistic when a time series has a shift in its level and the corresponding volatility. The proposed tests are robust to a wide class of partially stationary processes with heavy-tailed errors, and have an exact binomial null distribution. Our tests are not affected by the size or location of the break. We set the structural break under the null and the alternative hypotheses to relieve a possible vagueness in interpreting test results in empirical work. The null hypothesis implies a unit root process with level shifts and the alternative connotes a stationary process with level shifts. The Monte Carlo simulation shows that our tests have stable size than the OLSE based tests.

Hydrographic Model Test on Prevention against Vortex Occurrence for Vertical Bulb Turbine

  • Yamato, Shoichi;Nakamura, Shogo;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.418-425
    • /
    • 2009
  • A vertical bulb turbine unit with elbow type draft tube has been developed due to avoidance of complicated assembling and long standstill period at overhaul in comparison with conventional horizontal bulb turbine unit. Before designing the prototype vertical bulb unit, a hydrographic model test was carried out to establish the ideal design concept for this innovative generating unit. Froude similarity is not available for vortex occurrence. Consequently, an intake structure without air entraining vortices under all the flow conditions is developed, and it is confirmed that the surge wave at load rejection is not affected harmful influence for other constructions.

Evaluation Criteria of Reliability on Transmission Control Unit for Passenger Car

  • Choi, M.;Ryu, S.;Lim, J.H.;Jeong, H.S.
    • International Journal of Reliability and Applications
    • /
    • v.11 no.1
    • /
    • pp.55-67
    • /
    • 2010
  • There has been a recent upsurge in demand for the improvement of car reliability in the Northern American which is the primary market of South Korea automobile industry. It has been required that the warranty for transmission control unit for passenger cars directly related to passenger safety or security should be extended for 10 years and 160,000 km. In this paper, the test method for reliability and evaluation criteria is presented to evaluate the reliability on the automatic transmission controller. Reliability certification test can be roughly divided into two types: a quality test and life assessment test and a quality test can be subdivided into a basic performance test and environmental resistance test. There are 3 types of tests on the performance test for automatic transmission controller and environmental resistance test is composed of 14 items. Life test is performed with only the product passed this quality test. In this study, operation limit test at the high-temperatures, accelerated life test under specific temperature and accelerated life test for 2 or 3 stress levels are shown as a way for life test.

  • PDF

A Study on Architecture of Test Program based UML (UML 기반 점검 프로그램 설계 방법에 관한 연구)

  • Kim, ByoungYong;Jang, JungSu;Ban, ChangBong;Lee, HyoJong;Yang, SeungYul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.217-230
    • /
    • 2012
  • This paper propose interacting test programming methods between test equipment and hardware unit to verify function and performance of the hardware unit under test. Proposed test program can minimizes the risk of failures when the unit is mounted on the aircraft by testing and verifying the unit under the worst stress condition. Also, Object oriented design using UML make it easy to apply in other equipments. Test program consists of architecture package and hardware package. Architecture package is in a role for system management, log analysis, message receiving and message analysis. Messages that are used by system management define messages for testing and defined messages is sent and received to test equipment through Ethernet. Hardware package is in a role for hardware management that is needed to be tested and is related to a system. Hardware to be tested is divided into internal test and transmission test. Internal test inspects hardware itself and reports the test results to the test equipment. Transmission test inspects communication device by sending or receiving data. All kinds of test is done in the worst condition of the test unit executing in parallel. Each device is tested at least 482 times and at most 15,003 times about one hour. Test program is utilized in hardware reliability test like as environmental test or EMI test.