• 제목/요약/키워드: Unit construction system and Design unit

검색결과 193건 처리시간 0.03초

시스템 에어컨에 의한 실내 소음 평가 및 개선 설계 (Estimation of the Noise Caused by the System Air Conditioner and its Improvement)

  • 이제원;주재만;오상경;송용재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF

구조해석 및 시험에 의한 경량화 차체 구조강도 평가 (Structural Strength Evaluation of a Carbody by Finite Element Analysis and Tests)

  • 윤성철;김원경;전창성;김명룡
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.49-54
    • /
    • 2005
  • This paper describes the result of structure analysis and load test of body structure. The purpose of the analysis and test is to evaluate an safety which body structure shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load and operating condition. Material of body structure applied an aluminum alloy. Body structure consist of side frame, under frame, roof frame, end frame. Both FEM analysis and load test are based on 'Performance Test Standard for Electrical Multiple Unit, noticed by Ministry of Construction & Transportation, in 2000' and reference code is JIS E 7105. The test results have been very safety and stable fer design load conditions.

  • PDF

마이크로컴퓨터를 이용한 FFT 분석기의 설계 및 제작 (Design and Construction of a FFT Analyzer Using a Microcomputer)

  • 이현태;김중규;이상배
    • 대한전자공학회논문지
    • /
    • 제23권6호
    • /
    • pp.944-949
    • /
    • 1986
  • By improving the ability of arithmatic processing with an arithmatic processor in a microcomputer and realizing the data input system for real time analysis, an FFT analyzer that is usable within the range of audio frequency is designed and constructed. The input signal passes through a gain programmable pre-amplifier and anti-aliasing lowpass filter into an analogditital converter to be converted into digital form. The converted input data is processed by an Apple II microcomputer. The results of the processing are displayed using a microcomputer display unit and can be copied on a printer or stored in a floppy disk.

  • PDF

30 kg/hr 급 열분해 용융 소각로에서의 폐기물 열분해/연소/용융 특성 연구 (Combustion and Pyrolysis Characteristics of Solid Wastes in a 30 kg/hr Capacity Pyrolysis Melting Incinerator)

  • 류태우;김봉근;양원;전금하;신동훈;박상욱;임성진;김대성;이진호;황정호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.172-180
    • /
    • 2006
  • A novel pyrolysis-melting incineration system of reduced scale (30 kg/hr) is and constructed in Korea Institute of Industrial Technology. The incineration process is composed of three parts: pyrolysis, gas combustion and ash melting processes. For each unit process, experimental and numerical approaches including reduced-scale cold/hot flow tests have been conducted to find optimal design and operating conditions. This paper presents major results of these approaches with brief descriptions on the pilot-scale incinerator (200 kg/hr) under construction and future research works.

  • PDF

역할 기반 변동 보안 룰셋 적용을 위한 네트워크 보안 게이트웨이 설계에 관한 연구 (A Study on the Design of the Security Gateway for Role-based Dynamic Security Rule-Set)

  • 이춘재;조기량
    • 한국통신학회논문지
    • /
    • 제33권8B호
    • /
    • pp.719-726
    • /
    • 2008
  • 본 논문에서는 보안 게이트웨이가 서브넷 상의 단말기의 네트워크 접근 시도 시에 해당 단말기를 자동으로 인식하여 단말기 사용자의 인증 및 접근 제어 보안 룰셋을 기간 데이터베이스와 비교 판별하여 동적으로 조직 내의 역할 기반 접근 권한을 부여, 관리하는 방식에 대해 연구하였다. 덧붙여, 네트워크 관리자가 조직 구조와 관련하여 네트워크 레벨(L2)과 어플리케이션 레벨(L7)의 통합 액세스 제어를 지정할 수 있도록 사용자 중심의 권한 부여 모델을 제시하였다.

Vibration control for serviceability enhancement of offshore platforms against environmental loadings

  • Lin, Chih-Shiuan;Liu, Feifei;Zhang, Jigang;Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.403-414
    • /
    • 2019
  • Offshore drilling has become a key process for obtaining oil. Offshore platforms have many applications, including oil exploration and production, navigation, ship loading and unloading, and bridge and causeway support. However, vibration problems caused by severe environmental loads, such as ice, wave, wind, and seismic loads, threaten the functionality of platform facilities and the comfort of workers. These concerns may result in piping failures, unsatisfactory equipment reliability, and safety concerns. Therefore, the vibration control of offshore platforms is essential for assuring structural safety, equipment functionality, and human comfort. In this study, an optimal multiple tuned mass damper (MTMD) system was proposed to mitigate the excessive vibration of a three-dimensional offshore platform under ice and earthquake loadings. The MTMD system was designed to control the first few dominant coupled modes. The optimal placement and system parameters of the MTMD are determined based on controlled modal properties. Numerical simulation results show that the proposed MTMD system can effectively reduce the displacement and acceleration responses of the offshore platform, thus improving safety and serviceability. Moreover, this study proposes an optimal design procedure for the MTMD system to determine the optimal location, moving direction, and system parameters of each unit of the tuned mass damper.

지상신호설비의 유지보수 효율화를 위한 집중화 및 전자화 연구 (The Study on Centralization & Electronic for Maintenance Efficiency of Ground Signaling System)

  • 백종현;김용규;이강미
    • 한국산학기술학회논문지
    • /
    • 제11권8호
    • /
    • pp.2983-2988
    • /
    • 2010
  • 국내 철도 신호시스템은 전자화로 발전하고 있으며 이 중 연동장치의 전자화는 57%에 이르고 있고, 선로변장치 중 건널목 보안장치는 통합시스템으로 개발이 완료되어 있다. 그러나 기존선 전 구간의 폐색장치는 전자화 및 통합화가 되어있지 않아 건설과 유지보수 측면에서 많은 보완점을 가지고 있다. 현재 국내 기존선에 사용되고 있는 ABS와 경부 및 호남선에 설치중인 LEU는 동일한 장소에서 동일한 열차의 신호정보에 의해 열차를 제어하고 있음에도 불구하고 각각 별개의 시스템으로 분리되어 설치되어 있기 때문에 동일한 정보를 각각 별개로 나누어 송수신하여 열차를 제어하고 있다. 따라서 종래의 ABS와 LEU에서는 램프검지부나 전원부 등과 같이 중복 설치된 부품이 많기 때문에 전체적인 제품의 제조 원가가 높아질 뿐만 아니라, 시공비 역시 2중으로 소요되고 유지보수에도 많은 인력과 비용을 투자해야 하는 등의 문제가 있다. 따라서 본 논문에서는 현재 사용 중인 ABS에 통신 및 전자기술을 접목시켜서 집중형 전자폐색제어장치를 개발하기 위한 내용을 제시하고 있으며, 해당역 관내 폐색장치를 집중감시 및 관리를 하고 ATP 시스템의 지상장치인 LEU와 연계하여 정보 전송이 가능하도록 하고자 한다.

지능형 대용량 비례유량제어밸브 서보컨트롤러 설계 (Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity)

  • 정규홍
    • 유공압시스템학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

공동주택단지에 설치된 부스터펌프 급수설비계통의 유동 특성 (Flow Characteristics of a Water Supply System with Booster Pumps for an Apartment Complex)

  • 오양균;정재봉;박미라;차동진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.151-156
    • /
    • 2008
  • Water flow characteristics of an apartment complex consisting of 12 buildings and 635 units in total have been investigated numerically. The complex incorporates two zone booster pump water supply system, and some units have pressure reducing valves in them. Input data to a commercial code Flowmaster7 include survey results on the water usage for the last three years, dimension of the water supply system and its operation condition, etc. Calculated static pressures at the inlet of all units are compared with their design and measured counterparts, and they agree quite well with each other. Then, the pressure distributions and volumetric flow rates at all 635 units are estimated. Flow balancing is also attempted by varying the ratio of angle valve of each unit to improve the non-uniformity of flows.

  • PDF

심층혼합처리공법(DCM)의 설계, 시공 및 품질관리 사례 연구 (The Case Study on the Design, Construction, Quality Control of Deep Cement Mixing Method)

  • 김병일;박언상;한상재
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.19-32
    • /
    • 2021
  • 본 연구에서는 심층혼합처리공법에 관하여 저자들에 의해 수행된 국내/외 설계, 시공 및 품질관리에 대한 평가와 고찰을 수행하였고, 추후 DCM 공법의 발전을 위한 개선 사항들을 제시하였다. 본 연구 결과, 실내배합실험 시 강도에 대한 단면적 보정이 필요하고, 외삽법 적용 시 실제와 다른 결과가 도출될 수 있으므로 주의가 요구됨을 알 수 있었다. 설계 시 개량율과 개량형식 등을 모두 고려하여 적용 가능한 설계법을 선정해야 하며, 안전율이 적용된 허용압축강도는 안정성 검토를 위한 기준치를 의미하는 것이지 설계 지반정수가 아님을 확인하였다. 응력분담비의 경우 관행적인 값을 적용하기 보다는 설계 조건을 반영한 실험 및 이론적 응력분담비를 산정해야 경제적인 설계를 수행할 수 있었다. 시공 시 선천공이 예상되는 경우 증가된 함수비가 원지반 대비 크지 않은 경우 함수비 증가를 고려하지 못한 결과를 사용하여도 큰 문제가 발생하지 않는 경우도 있었다. 또한, 개량길이 대비 선단처리 길이의 비율이 높은 경우 시공 시 단위길이당 설계 시멘트량이 적게 주입될 수 있음을 확인하였다. 품질관리 시 개량체 코어링은 1축 개량체는 D/4~2D/4, 다축 개량체는 D/4 지점이 최적인 것으로 평가되었다. 품질관리를 위한 항목으로 개량체의 일축압축강도와 더불어 TCR을 고려하는 기준이 국내 실정에 더 적합할 것으로 판단된다.