• Title/Summary/Keyword: Unit calculation

Search Result 721, Processing Time 0.032 seconds

Sediment Transport Calculation Considering Cohesive Effects and Its Application to Wave-Induced Topographic Change (점착력을 고려한 표사유동 수치모델의 제안과 파랑에 의한 지형변동의 적용성 검토)

  • Cho, Yong Hwan;Nakamura, Tomoaki;Mizutani, Norimi;Lee, Kwang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.6
    • /
    • pp.405-411
    • /
    • 2013
  • A sediment transport calculation considering cohesive force is proposed to deal with the transport phenomena of cohesive sediment. In the proposed calculation, each sand particle is assumed to be surrounded by a thin layer of mud. The critical Shields parameter and bed-load sediment transport rate are modified to include the cohesive force acting on the sand particle. The proposed calculation is incorporated into a two-way coupled fluid-structure-sediment interaction model, and applied to wave-induced topographic change of artificial shallows. Numerical results show that an increase in the content ratio of the mud, cohesive resistance force per unit surface area and water content cause increases in the critical Shields parameter and decreases in the bed-load sediment transport rate, reducing the topographic change of the shallow without changing its trend. This suggests that mixing mud in the pores of the sand particles can reduce the topographic change of shallows.

Limitations and Improvement of Using a Costliness Index (진료비 고가도 지표의 한계와 개선 방향)

  • Jang, Ho Yeon;Kang, Min Seok;Jeong, Seo Hyun;Lee, Sang Ah;Kang, Gil Won
    • Health Policy and Management
    • /
    • v.32 no.2
    • /
    • pp.154-163
    • /
    • 2022
  • Background: The costliness index (CI) is an index that is used in various ways to improve the quality of medical care and the management of appropriate treatment in medical institutions. However, the current calculation method for CI has a limitation in reflecting the actual medical cost of the patient unit because the outpatient and inpatient costs are evaluated separately. It is desirable to calculate the CI by integrating the medical cost into the episode unit. Methods: We developed an episode-based CI method using the episode classification system of the Centers for Medicare and Medicaid Services to the National Inpatient Sample data in Korea, which can integrate the admission and ambulatory care cost to episode unit. Additionally, we compared our new method with the previous method. Results: In some episodes, the correlation between previous and episode-based CI was low, and the proportion of outpatient treatment costs in total cost and readmission rates are high. As a result of regression analysis, it is possible that the level of total medical costs of the patient unit in low volume medical institute and rural area has been underestimated. Conclusion: High proportion of outpatient treatment cost in total medical cost means that some medical institutions may have provided medical services in the ambulatory care that are ancillary to inpatient treatment. In addition, a high readmission rate indicates insufficient treatment service for inpatients, which means that previous CI may not accurately reflect actual patient-based treatment costs. Therefore, an integrated patient-unit classification system which can be used as a more effective CI indicator is needed.

Medicare's Reimbursement for Innovative Technologies: Focusing on Artificial Intelligence Medical Devices (미국의 혁신의료기술 지불보상제도: 인공지능 의료기기를 중심으로)

  • Lee, Boram;Yim, Jaejun;Yang, Jangmi
    • Health Policy and Management
    • /
    • v.32 no.2
    • /
    • pp.125-136
    • /
    • 2022
  • The costliness index (CI) is an index that is used in various ways to improve the quality of medical care and the management of appropriate treatment in medical institutions. However, the current calculation method for CI has a limitation in reflecting the actual medical cost of the patient unit because the outpatient and inpatient costs are evaluated separately. It is desirable to calculate the CI by integrating the medical cost into the episode unit. We developed an episode-based CI method using the episode classification system of the Centers for Medicare and Medicaid Services to the National Inpatient Sample data in Korea, which can integrate the admission and ambulatory care cost to episode unit. Additionally, we compared our new method with the previous method. In some episodes, the correlation between previous and episode-based CI was low, and the proportion of outpatient treatment costs in total cost and readmission rates are high. As a result of regression analysis, it is possible that the level of total medical costs of the patient unit in low volume medical institute and rural area has been underestimated. High proportion of outpatient treatment cost in total medical cost means that some medical institutions may have provided medical services in the ambulatory care that are ancillary to inpatient treatment. In addition, a high readmission rate indicates insufficient treatment service for inpatients, which means that previous CI may not accurately reflect actual patient-based treatment costs. Therefore, an integrated patient-unit classification system which can be used as a more effective CI indicator is needed.

Relationship between Spinopelvic Parameters and Hip Function in Patients with Femoroacetabular Impingement at Diagnosis: A Cross-Sectional Study

  • Bernardo Aguilera-Bohorquez;Pablo Corea;Cristina Siguenza;Jochen Gerstner-Saucedo;Alvaro Carvajal;Erika Cantor
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.6-14
    • /
    • 2023
  • Purpose: The aim of this study was to determine correlation between the spinopelvic parameters in sitting and standing positions (sacral slope [SS], lumbar lordosis [LL], spinopelvic tilt [SPT], pelvic incidence [PI], and pelvic femoral angle [PFA]), with hip function assessed using the modified Harris hip scores (mHHs) in patients with symptomatic femoroacetabular impingement (FAI) at diagnosis. Materials and Methods: A retrospective study of 52 patients diagnosed with symptomatic FAI was conducted. Evaluation of the spinopelvic complex in terms of SS, LL, SPT, PI and PFA was performed using lateral radiographs of the pelvis and lumbosacral spine in standing and sitting positions. Assessment of hip function at diagnosis was performed using the mHHs. Calculation of spinopelvic mobility was based on the difference (Δ) between measurements performed in standing and sitting position. Results: The median time of pain evolution was 11 months (interquartile range [IQR], 5-24 months) with a median mHHs of 66.0 points (IQR, 46.0-73.0) at diagnosis. The mean change of LL, SS, SPT, and PFA was 20.9±11.2°, 14.2±8.6°, 15.5±9.0°, and 70.7±9.5°, respectively. No statistically significant correlation was observed between spinopelvic parameters and the mHHs (P>0.05). Conclusion: Radiological parameters of the spinopelvic complex did not show correlation with hip function at the time of diagnosis in patients with symptomatic FAI. Conduct of further studies will be required in the effort to understand the effect of the spinopelvic complex and its compensatory mechanics, primarily between the hip and spine, in patients with FAI before and after hip arthroscopy.

The Estimation of Soil Conversion Factor using Digital Imagery (수치영상을 이용한 토량환산계수 산정)

  • 이종출;차성렬;장호식;김진수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.169-174
    • /
    • 2003
  • Design of a rational earth volume conversion coefficient is required as the earth volume conversion coefficient may give great influence on construction work volume and construction costs in the civil engineering works where large-scaled earth volume is excavated. However, there are a great deal of difficulties in the calculation of the exact spoil surface earth and Insufficient earth volume by adopting the figures presented on the generally used design specifications which are not the results obtained from the selection tests in calculating the earth volume conversion coefficient. In this connection, it would be desirable to calculate the earth volume conversion coefficient by carrying out large-scaled site test adequate for the relevant environment. In consequence, this study aims at calculating the exact earth volume conversion coefficient of cutting and banking areas of weathering rocks in large-scaled construction sites where land is being developed into home lots. For this, we have excavated the respective 20 sites of the cutting and banking areas in the said site and then calculated the volume after the excavation. As a result, the relative exactness degree of the crossing was calculated at 0.5% in average. The relative exactness degree of 0.5% in the volume may be judged as an exact measurement as it corresponds to 0.17% of the relative exactness degree in the length measurement. We have calculated the exact earth volume conversion coefficient by the use of function ratio as per the wet unit weight and the indoor soil quality test as per volume calculated. And then we have found out minor differences as a result of the comparison and analysis with the earth volume conversion coefficient determined by the dry unit weight test as per sand replacement method. This may be judged as a rational design method for the calculation of earth volume conversion coefficient, as well as high reliability of site test as a precision photogrammetry is adopted for volume measurement of the irregular excavating areas.

  • PDF

Estimation of Mechanical Properties for Particle Dispersed Composites (입자 분산 복합재료의 기계적 성질 추정)

  • Tak Jin Moon;Dae Soon Im
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.414-420
    • /
    • 1982
  • The mechanical properties of nickel particle polyethylene composites were estimated by using a finite element method. Two steps were carried out in this analysis; the first step was to consider an unit model composed of spherical cell in the center of the matrix and the second step was to consider a total model composed of unit model. Two phase and three phase models were used, since another third phase were observed between matrix and nickel particle. Finite element method permits the calculation of the stress and displacement, assuming the arbitrary loads. Elastic modulus, Poisson's ratio and stress distribution of composites were obtained from this output. Comparison of the calculation by finite element method and the experimental results for Ni-filled polyethylene showed good agreement in tensile properties.

  • PDF

Efficient DSP Architecture for Viterbi Algorithm (비터비 알고리즘의 효율적인 연산을 위한 DSP 구조 설계)

  • Park Weon heum;Sunwoo Myung hoon;Oh Seong keun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3A
    • /
    • pp.217-225
    • /
    • 2005
  • This paper presents specialized DSP instructions and their architecture for the Viterbi algorithm used in various wireless communication standards. The proposed architecture can significantly reduce the Trace Back (TB) latency. The proposed instructions perform the Add Compare Select (ACS) and TB operations in parallel and the architecture has special hardware, called the Offset Calculation Unit (OCU), which automatically calculates data addresses for the trellis butterfly computations. Logic synthesis has been Performed using the Samsung SEC 0.18 μm standard cell library. OCU consists of 1,460 gates and the maximum delay of OCU is about 5.75 ns. The BER performance of the ACS-TB parallel method increases about 0.00022dB at 6dB Eb/No compared with the typical TB method, which is negligible. When the constraint length K is 5, the proposed DSP architecture can reduce the decoding cycles about 17% compared with the Carmel DSP and about 45% compared with 7MS320c15x.

A Study on the Optimum Size Calculation of Unit Classroom in Elementary School Based on the Size of the Human Body and the Layout of Teaching Tools and Desks (인체치수와 교구배치를 고려한 초등학교 일반교실의 규모산정계획에 관한 연구)

  • Kim Hak-Rae
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.17-30
    • /
    • 2006
  • This study is for the size calculation of classroom based on the size of human body and teaching tools. The curriculum of Elementary school has been changed since 1960. It has been reflected on the size of classroom of elementary school. The new education curriculum-the 7th curriculum- demands various activities in classroom. And the Ministry of Education repealed the statute about the facilities of the schools on September in 1997. So we need to different size of unit space of the classroom in elementary school because the size of classroom will affect the quality of education. It is generally known that a part of human body-size has an invariable proportion with human's status, age and weight. In this study, regression analysis is used to find out a part of human body-size of Korean. Then the size of classroom is calculated by the part of human body-size, teaching tools and the type of desk arrangement.

  • PDF

Estimation of Radioactive Inventory for a major component of Reactor in Decommissioning (해체시 원자로 주요 구성품에 대한 방사능 재고량 평가)

  • Hak-Soo Kim;Ki-Doo Kang;Kyoung-Doek Kim;Chan-Woo Jeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.69-75
    • /
    • 2004
  • DORT and ORIGEN2 code were used for calculation of neutron flux and inventory in reactor pressure vessel(RPV) of Kori unit-1, To calculate neutron flux using DORT code, the reactor was divided into 94 mesh from the center of core to RPV and from 0 to 45 degree along the azimuth. The cross-sections of main nuclides were recalculated using neutron flux in the RPV region. The results showed that 95% of the total activity in RPV came from the nuclides of $^{55}$ Fe, $^{60}$ Co, $^{59}$ Ni and $^{63}$ Ni. And the total activity with cooling of more than 50 years after decommissioning was no more than 0.2% of at the time of shutdown. Considering the weight of RPV is 210 tons, the initial total activity of RPV reached 5.25${\times}$10$^{6}$ GBq. To verify results of ORIGEN2 calculation, comparison between calculated and measured value at RPV of Kori unit-1 was peformed. The comparison results showed a good agreement.

  • PDF

Comparison of Iron(Fe) Data of ENDF/B-IV and VI in Yonggwang Nuclear Unit-3/4 Vessel Fluence Calculation (영광 3/4호기 압력용기의 중성자 조사량계산을 통한 ENDF / B-IV와 VI 철(Fe) 자료의 비교)

  • Kim, Tae-Hyeong;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.74-83
    • /
    • 1995
  • The accurate determination of the fast neutron flux/fluence onto the pressure vessel is an essential part of the reactor pressure vessel surveillance program. It has been reported recently that the iron cross section data in ENDF/B versions III through V might underestimate the flux/fluence of fast neutrons in steel structures such as reactor pressure vessel. In this study, for the comparison of iron data of ENDF/B-IV and VI we produced two 47-group cross section sets, CXFe-IV and CXFe-Ⅵ, which are based on Yonggwang nuclear unit-3/4 model and the iron data of ENDF/B-IV and VI, respectively. A comparison was made of the results obtained from DOT4.3 calculation using CXFe-IV and CXFe-VI. From the results, it was found that the fast flux(E 〉 1.0 MeV), which is important for the pressure vessel embrittlement analysis, increases by about 7.6% at the inner wall and 20% at the outer wall of the vessel, if the iron data are used from ENDF/B-VI instead of ENDF/B-IV.

  • PDF