• 제목/요약/키워드: Unit building method

검색결과 387건 처리시간 0.023초

원가산정을 위한 표준분류체계 활용한 지식체계 개발 (Knowledge Structure for Cost Estimates Based on Standardized Cost Database)

  • 임혜경;강남희;최재현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2016
  • The importance of construction management has been increasing due to the fact that complex construction projects blend several different industries depending on the traits of the construction. This research was conducted to search for a method to enhance efficiency in cost management of construction project and meet the need for reusability of accumulated construction information. The process of detailed estimation and methodology for using standard unit price information has been developed to strengthen the interoperability in cost information by utilizing a standard classification system. The concept of ontology is proposed as a method of connecting construction information based on a standard breakdown structure to increasing the connectivity of the cost information in the construction project. Therefore, construction information knowledge framework is developed in order to improve the efficiency of the detailed estimation work process.

  • PDF

보행하중을 받는 건축물 바닥판의 진동해석 (Vibration Analysis of Building Floor Subjected to Walking Loads)

  • 김기철;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF

Modeling of temperature history in the hardening of ultra-high-performance concrete

  • Wang, Xiao-Yong
    • 한국건축시공학회지
    • /
    • 제14권3호
    • /
    • pp.273-284
    • /
    • 2014
  • Ultra-high-performance concrete (UHPC) consists of cement, silica fume (SF), sand, fibers, water and superplasticizer. Typical water/binder ratios are 0.15 to 0.20 with 20 to 30% silica fume. In the production of ultra-high performance concrete, a significant temperature rise at an early age can be observed because of the higher cement content per unit mass of concrete. In this paper, by considering the production of calcium hydroxide in cement hydration and its consumption in the pozzolanic reaction, a numerical model is proposed to simulate the hydration of ultra-high performance concrete. The heat evolution rate of UHPC is determined from the contributions of cement hydration and the pozzolanic reaction. Furthermore, by combining a blended-cement hydration model with the finite-element method, the temperature history in the hardening of UHPC is evaluated using the degree of hydration of the cement and the silica fume. The predicted temperature-history curves were compared with experimental data, and a good correlation was found.

도로 주행 시험을 통한 모듈러 유닛의 진동 특성 분석 (Analysis of Vibration Characteristics of Modular Unit by Road Test)

  • 곽명근;백정훈;설욱제
    • 대한건축학회논문집:계획계
    • /
    • 제35권1호
    • /
    • pp.29-35
    • /
    • 2019
  • The unit modular system is a type of prefabricated construction method that completes the building by uniting the modular units on site by transporting the unit module structure manufactured in the factory to the site. Since the unit module structure is not only the frame but also the finished form including the inner and outer materials, it is most likely to be brought into the field. Therefore, not only the damage of the inner and outer materials but also deformation of frame structure due to the vibration generated during the transportation of the vehicle, And it is necessary to take appropriate methods when transporting the module structure. However, there are no methods to prevent modular structure damage due to vehicle vibration in domestic and foreign modular transportation guidelines or standards. In this study, we investigate the vibrations during the vehicle transportation of the module structure through the road driving test, identify the vibration frequency characteristics of the vehicle through FFT analysis, and propose a vibration reduction methods for module transportation.

The Characteristics of the Repair Cost Distribution in Apartment Housing

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.19-26
    • /
    • 2015
  • Purpose: The repair would require to conserve and improve the building function and performance since built. Each household is responsible for maintaining the public facilities and paying the required cost. Therefore, it needs to get the tool or method to forecast the required cost in the future. Before the repair cost is provided, it needs to catch the repair cost distribution and provide the unit cost for the repair cycle. In this study, it aimed at providing the repair cost unit and analyzing the repair cost distribution in a roof proofing work, elevator work and building painting, which are divided into a fully work and partly change. Results of this study are shown that first, the average repair cost for roof proofing work is provided with $166.59{\times}10^3won/household$ and $1.59{\times}10^3won/m^2$ of a full change, $33.22{\times}10^3won/household$ and $0.33{\times}10^3won/m^2$ for a partly work. In addition, elevator work is $557.45{\times}10^3won/household$ and $5.38{\times}10^3won/m^2$ for a full change, $32.92{\times}10^3won/household$ and $0.56{\times}10^3won/m^2$ for a partly repair. Painting has a $304.48{\times}10^3won/household$ and $2.94{\times}10^3won/m^2$. Second, the distribution pattern of repair unit cost has a weibull-typed distribution which has a long tail to the right.

Preparation and Properties of Green Environment-Friendly Drilling Polymer Mud

  • Zhang, Feng-Jun;Sun, Xian-Yang;Li, Xuan;Kong, Cui;Liu, Jin;Chen, Qian-Bao;Oh, Won-Chun
    • 한국재료학회지
    • /
    • 제29권11호
    • /
    • pp.664-669
    • /
    • 2019
  • In this paper, a water-based green polymer mud is synthesized by simple compounding method. Effects of different kinds of tackifiers, their molecular weight on the viscosity of polymer mud and the effects of different fluid loss additives on mud fluid loss are studied. The results show that when polystyrene and anionic polyacrylamide with molecular weight of 8 ~ 10 million are used as the main thickening ingredient, polymer mud with high viscosity and high stability can be obtained. When the prepared polymer mud is formulated as NPAM: PEO: Hydroxypropyl cellulose(HPC) : Water = 42:10:10:100000 (unit: kg), the viscosity can reach 20.6 s, the filtration loss in 7.5 min is 24 mL, and the sand content is only 0.1 %. Compared with traditional bentonite mud, the green environment-friendly polymer mud has the advantages of small amount of waste, low environmental pollution, and low pulping cost, and can meet the construction needs for most topography and geomorphology drilling engineering.

GIS 자료와 연계한 시나리오별 홍수피해액 분석 (Flood Damage Assessment According to the Scenarios Coupled with GIS Data)

  • 이근상;박진혁
    • 대한공간정보학회지
    • /
    • 제19권4호
    • /
    • pp.71-80
    • /
    • 2011
  • 우리나라는 홍수피해를 평가하기 위한 방법으로 간편법과 개선법을 사용하다가 현재는 2004년도에 개발된 다차원 홍수피해액 산정기법을 활용하고 있다. 본 연구에서는 GIS 자료를 기초로 다차원 홍수피해액 산정기법을 이용한 댐 하류지역의 홍수피해액 평가기법을 제시하였다. 먼저 배수강제알고리듬에 기초한 횡단측선 레이어에 FLDWAV 모델을 이용한 홍수위 자료를 입력한 후 DEM 자료와의 공간연산 처리를 통해 침수심 격자를 생성하였다. 그리고, 수치지형도에서 추출한 건물 레이어와 토지피복도에서 추출한 농경지 자료를 이용하여 지자체별 건물과 농경지 자산가치를 평가하였다. 또한 건축형태별 건축단가, 도시유형별 가정용품 평가액, 농작물 단가정보, 사업체의 유형 및 재고자산 평가액 자료를 건물, 농경지, 침수심 레이어와 연계하여 항목별로 피해액을 산정하였다. 홍수피해액 분석을 통해, 200년 빈도의 홍수피해액이 100년, 50년, 10년 빈도에 비해 각각 1.19배, 1.30배 그리고 1.96배 높게 나타났다.

흙과 모래의 최밀충전효과와 석회복합체의 첨가에 따른 강도 증진 (Increasing the Strength with Earth and Soil through Optimum Micro-filler Effect and Lime Composite Addition)

  • 황혜주;노태학;강남이
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.95-101
    • /
    • 2011
  • Earth has been used as a building material not only our country but also many foreign countries in the world. In foreign countries, we can often find the high-storied earthen houses which have been maintained for over several hundred years, which means the fact that earth differs in durability according to the methods of utilizing earth. So, the purpose of this study is to progress the fundamental research for utilizing earth as a wall material. Also, the another purpose of this study is to utilize the optimum micro-filler effect which adjusts the grain size of earth and the lime composite which promotes chemical combining power, and so examine whether earth material ensures its high compressive strength. This study applied both of rammed earth method and pour earth method among earth architecture methods. This study investigated compressive strength, slump, and air content according to unit binder weight. On the basis of such experimental results, this study derived the following conclusions. 1) Optimum micro-filler mixtures reduce a lot of fine particles contained in earth. If optimum micro-filler mixtures are used as aggregates, they develop lower W/B and relatively higher strength than general earth. 2) In this study, which uses optimum micro-filler earth mixtures and lime composite, rammed earth method develops 29MPa and pour earth method develops 28MPa in 28 days compressive strength. Such strengths can be utilized in building walls.

전문건설업체 작업일보의 정보구성에 관한 연구 (Information Constitution of Daily Job-Site Report for Specialty Contractors)

  • 이강민;신원상;이동은;김대영;손창백
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.279-280
    • /
    • 2012
  • The Construction Standard Production Unit(CSPU) has been used for the standard cost estimate in public and private construction projects. However, It is questionable if the reliability and/or authenticity of the system is acceptable due to the lack of consistent enactment and/or revision procedures. This study identifies informational conditions and issues relative to using daily work report as a data collection method for enacting and/or revising CSPU system, and establishes the measures for improving the daily work report. This study aims on the information constitution of daily job-site report, daily manpower report, wages register for specialty contractors. According to the research results, most of necessary data were included in a daily job-site report. In conclusion, it is investigated that data of daily manpower report and wage register need to be included in a daily job-site report for understanding the current state of worker in the future.

  • PDF

신개발지 일반주거지역의 용도전환시 공간변용 특성에 관한 연구 - 대전 둔산 신시가지를 중심으로 - (A Study on the Characteristics of Space Utilization after converting of Residential District in a New Development Area - Focused on Dunsan of Daejeon City -)

  • 박정아;강인호
    • 한국주거학회논문집
    • /
    • 제21권1호
    • /
    • pp.123-130
    • /
    • 2010
  • The purpose of this study is to find the characteristics of space utilization and the problems that follows after converting in a new developmental residential area. This study used the content-analysis method and analysis was made on the floor plans for 95 different conversion cases. Above all, 190 unit plans (the unit plans for conversion before and after) were analyzed. The results of this study were as follows; 1) There were 8 types of conversion according to such usages as residential, commercial and residential-commercial buildings. 2) In the case of conversions, from residential to commercial, there was a tendency each floor was integrated to exclusive use for commercial or commercial with small portions of residential usage. And in the case of conversions from commercial to residential, there was a tendency that all space of each floor were changed to exclusive usages for residential purposes. 3) In case of usage conversion from commercial to residential, there were constraints for balcony installation, because of its original lot-structure and building equipments. Also, when the basement was converted for residential purpose, there was no possibility for an extra lighting or ways to ventilate the area.