• Title/Summary/Keyword: Unit bias

Search Result 161, Processing Time 0.025 seconds

A DC~7GHz Ultrabroad-Band GaAs MESFET (DC~7GHz 초광대역 GaAs MESFET 증폭기)

  • 윤영철;장익수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.3
    • /
    • pp.34-42
    • /
    • 1993
  • An analytic approach to wide-band amplification using simplified equivalent MESFET modeling has enabled an ultrabroad-band flat-gain amplifier from DC to microwave. The developed lossy-match ultrabroad-band amplifier operates as a RC coupled circuit in the low-frequency range and lossless impedance matching circuit in the microwave frequency range with gain compensation circuits. The reduced gain caused by external resistors is compensated using 2-stage cascade amplification, and the gain of designed unit is 12.5.+-.1dB from the vicinity of DC to 7GAz. The experimental gain characteristics are good agreement with computer simulated results. The input and output VSWRs are measured under 2:1 over the operating frequency range, and the gain goes down over 15dBrange with various gate bias voltages.

  • PDF

Design of Window Applicable Blind-type Frequency Selective Surface

  • Lee, In-Gon;Hong, Ic-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.682-685
    • /
    • 2014
  • In this paper, we presented the window applicable blind-type frequency selective surface to control the coverage area of wireless communication in secure building or conference room. The proposed frequency selective structure has the reconfigurable frequency range depends on its blind rotation angle. To verify the proposed structure, we fabricated the window blind-type frequency selective surface with four-legged loaded element and ring-type element as a unit cell and performed measurements of the transmission characteristics for different blind rotation angles to prove the feasibility. The measurement results show good agreements with the simulation results. One of the advantages is that the proposed structure does not need to have a bias circuit, so it is very easy to implement at low cost and also can be applied to any planar surface for wireless security applications.

THREE-WAY BALANCED MULTI-LEVEL ROTATION SAMPLING DESIGNS

  • Park, Y. S.;Kim, K. W.;Kim, N. Y.
    • Journal of the Korean Statistical Society
    • /
    • v.32 no.3
    • /
    • pp.245-259
    • /
    • 2003
  • The 2-way balanced one-level rotation design has been discussed (Park et al., 2001), where the 2-way balancing is done on interview time in monthly sample and rotation group. We extend it to 3-way balanced multi-level design to obtain more information of the same sample unit for one or more previous months. The 3-way balancing is accomplished not only on interview time in monthly sample and rotation group but also on recall time as well. The 3-way balancing eliminates or reduces any bias arising from unbalanced interview time, rotation group and recall time, and all rotation groups are equally represented in the monthly sample. We present the rule and rotation algorithm which guarantee the 3-way balancing. In particular, we specify the necessary and sufficient condition for the 3-way balanced multi-level rotation design.

Dynamic and Stochastic Modeling of Litten´s space Inertial Reference Unit(SIRU)

  • Park, H.T.;K.Y Yong;B.S. Suk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.167.4-167
    • /
    • 2001
  • Accurate mathematical models of spacecraft components are an essential of spacecraft attitude control system design, analysis and simulation. Gyro is one of the most important spacecraft components used for attitude propagation and control. Gyro errors may seriously degrade the accuracy of the calculated spacecraft angular rate and of attitude estimates due to inherent drift and bias errors. In this paper, a detailed mathematical model of gyro containing the relationships for predicting spacecraft angular rate and disturbances is proposed. Stochastic model describing random drift behavior is discussed in frequency domain and time domain. In order to illustrate this approach, we analyze the behavior for Litton´s Space Inertial Reference Uint(SIRU).

  • PDF

Robust extreme quantile estimation for Pareto-type tails through an exponential regression model

  • Richard Minkah;Tertius de Wet;Abhik Ghosh;Haitham M. Yousof
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.6
    • /
    • pp.531-550
    • /
    • 2023
  • The estimation of extreme quantiles is one of the main objectives of statistics of extremes (which deals with the estimation of rare events). In this paper, a robust estimator of extreme quantile of a heavy-tailed distribution is considered. The estimator is obtained through the minimum density power divergence criterion on an exponential regression model. The proposed estimator was compared with two estimators of extreme quantiles in the literature in a simulation study. The results show that the proposed estimator is stable to the choice of the number of top order statistics and show lesser bias and mean square error compared to the existing extreme quantile estimators. Practical application of the proposed estimator is illustrated with data from the pedochemical and insurance industries.

Design of Flexible Reconfigurable Frequency Selective Surface for X-Band Applications (유연한 구조를 갖는 X-Band 재구성 주파수 선택구조 설계)

  • Lee, In-Gon;Park, Chan-Sun;Yook, Jong-Gwan;Park, Yong-Bae;Chun, Heung-Jae;Kim, Yoon-Jae;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.80-83
    • /
    • 2017
  • In this paper, the X-band reconfigurable frequency selective surface having flexible geometry was proposed. The proposed RFSS is composed of patterns of cross-shaped loop with inductive stub, which can control the frequency response for C-Band and X-band by ON/OFF state of PIN diode. To minimize the parasitic effect and to obtain the high level of isolation between the unit cell of FSS and the bias circuit, we designed the grid type bias line on bottom layer through via hole. The measured transmission characteristics show good agreement with the simulation results and good stability of frequency response for different incident angles and curvatures of surface.

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • 송인호;최창호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute(KAERI) in Taejon to supply power with Korea Superconducting Tokamak Advanced Research(KSTAR) Neutral Beam Injection(NBI) system. NBI system requires fast cutoff of the flower supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply. There are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply. Various results taken during the commissioning phase with a 100kW resistive load and NBI source arc shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver during thefabrication and test and solutions are also presented.

Monetary Policy in Open versus Closed Economies in the Presence of Distortions: A Simple Transformation and Its Applications (왜곡이 있는 경우 개방경제와 폐쇄경제의 통화정책 비교: 간단한 변환과 적용)

  • Jung, Kyu-Chul
    • KDI Journal of Economic Policy
    • /
    • v.36 no.1
    • /
    • pp.81-106
    • /
    • 2014
  • This paper compares the monetary policy problem in open economies with that in closed economies. It is found that the monetary policy problems in open and closed economies are isomorphic even in the presence of distortions in a steady state and hence the optimal monetary policies have similar properties. On the other hand, the monetary policy maker in open economies has a distorted incentive to manipulate the terms-of-trade. Because of the additional distortion in open economies, there exist gains from international monetary policy cooperation even in the case of a unit intertemporal elasticity of substitution, in contrast to the literature that abstracts from distortions in a steady state. Also, it is found that in the presence of distortions inflation bias is decreasing in openness, which is line with empirical evidence. In addition, this paper presents a simple transformation so that methods in closed-economy models are easily applicable to open-economy models.

  • PDF

Pooled Prevalence of Workplace Bullying in Nursing: Systematic Review and Meta-analysis (간호사간 직장내 괴롭힘 발생률에 관한 체계적 문헌고찰과 메타분석)

  • Kang, Jiyeon;Lee, Minju
    • Journal of Korean Critical Care Nursing
    • /
    • v.9 no.1
    • /
    • pp.51-65
    • /
    • 2016
  • Purpose: This study aimed to estimate the pooled prevalence of workplace bullying among nurses and examine the effect of moderate factors. Methods: Studies that assessed nursing workplace bullying using the negative act questionnaire developed by Einarsen et al. were searched for in 8 databases. The pooled prevalence was calculated with overall event rate and meta-ANOVA was performed for subgroup analysis. A funnel plot and Egger's linear regression asymmetry test were performed to confirm the publication bias of meta-analyzed studies. Results: A total of 23 studies (N=11,748) were included in the systematic review, and 14 studies (N=4,585) that reported prevalence using operational criteria of victim were selected for meta-analysis. The pooled prevalence of workplace bullying was 22.2% (95% CI: 19.0~25.7). Domestic studies reported lower prevalence than international studies (18.6% vs. 27.0%, Q=8.75, p=.003). The prevalences were different according to publication year (30.6% in 2008~2010, 19.5% in 2011~2014, 21.8% in 2015, Q=11.89, p=.003). Studies that recruited only new nurses reported higher prevalence than others (28.4% vs. 20.6%, Q=3.92, p=.048). Publication bias was not found. Conclusions: Workplace bullying is prevalent in the nursing profession, and is more serious for new graduate nurses. Individual and organizational measures for preventing workplace bullying among nurses need to be sought.

  • PDF

Retrieval of Thermal Tropopause Height using Temperature Profile Derived from AMSU-A of Aqua Satellite and its Application (Aqua 위성 AMSU-A 고도별 온도자료를 이용한 열적 대류권계면 고도 산출 및 활용)

  • Cho, Young-Jun;Shin, Dong-Bin;Kwon, Tae-Yong;Ha, Jong-Chul;Cho, Chun-Ho
    • Atmosphere
    • /
    • v.24 no.4
    • /
    • pp.523-532
    • /
    • 2014
  • In this study, thermal tropopause height defined from WMO (World Meteorological Organization) using temperature profile derived from Advance Microwave Sounding Unit-A (AMSU-A; hereafter named AMSU) onboard EOS (Earth Observing System) Aqua satellite is retrieved. The temperature profile of AMSU was validated by comparison with the radiosonde data observed at Osan weather station. The validation in the upper atmosphere from 500 to 100 hPa pressure level showed that correlation coefficients were in the range of 0.85~0.97 and the bias was less than 1 K with Root Mean Square Error (RMSE) of ~3 K. Thermal tropopause height was retrieved by using AMSU temperature profile. The bias and RMSE were found to be -5~ -37 hPa and 45~67 hPa, respectively. Correlation coefficients were in the range of 0.5 to 0.7. We also analyzed the change of tropopause height and temperature in middle troposphere in the extreme heavy rain event (23 October, 2003) associated with tropopause folding. As a result, the distinct descent of tropopause height and temperature decrease of ~8 K at 500 hPa altitude were observed at the hour that maximum precipitation and maximum wind speed occurred. These results were consistent with ERA (ECMWF Reanalysis)-Interim data (potential vorticity, temperature) in time and space.