• Title/Summary/Keyword: Unit Values

Search Result 1,688, Processing Time 0.027 seconds

Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine (5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가)

  • Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{\pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{\pm}18.2$, $44.8{\pm}10.0$, and $52.1{\pm}8.3{\mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor (흐름주입식 바이오센서용 기질용액 자동희석 장치 개발)

  • Song, D.B.;Jung, H.S.;Jung, D.H.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

Different estimation methods for the unit inverse exponentiated weibull distribution

  • Amal S Hassan;Reem S Alharbi
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.2
    • /
    • pp.191-213
    • /
    • 2023
  • Unit distributions are frequently used in probability theory and statistics to depict meaningful variables having values between zero and one. Using convenient transformation, the unit inverse exponentiated weibull (UIEW) distribution, which is equally useful for modelling data on the unit interval, is proposed in this study. Quantile function, moments, incomplete moments, uncertainty measures, stochastic ordering, and stress-strength reliability are among the statistical properties provided for this distribution. To estimate the parameters associated to the recommended distribution, well-known estimation techniques including maximum likelihood, maximum product of spacings, least squares, weighted least squares, Cramer von Mises, Anderson-Darling, and Bayesian are utilised. Using simulated data, we compare how well the various estimators perform. According to the simulated outputs, the maximum product of spacing estimates has lower values of accuracy measures than alternative estimates in majority of situations. For two real datasets, the proposed model outperforms the beta, Kumaraswamy, unit Gompartz, unit Lomax and complementary unit weibull distributions based on various comparative indicators.

An Improved Methodology of Monetary Values of the Unit Collective Dose for Intervention Against Long-Term Exposure Following a Nuclear Accident (원자력 사고후 장기피폭에 대한 개입을 위한 피폭선량 금전가 산정의 개선된 방법론)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Choi, Young-Gil;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.77-80
    • /
    • 2002
  • A more practice approach for the determination of monetary values of the unit collective dose for intervention against long-term exposure following a nuclear accident was proposed. In addition, she monetary values of the unit collective dose estimated from the proposed approach were compared with those estimated from the previous model, which are derived from assumptions of routine exposure and the same values are applied in a nuclear accident without modification, using Korean economic data. The monetary values based on the proposed approach showed a distinct difference depending on inequity in the distribution of individual doses. The discounting rate was also an important factor in determination of monetary values of the unit collective dose.

Evaluation of Pollutant Load Unit Factor for Calculating Pollutants Emission in Aquacultural Farms (양식계 오염원 배출량 산정을 위한 원단위 설정)

  • Park, Jae Hong;Park, Bae Kyoung;Rhew, Doug Hee;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.656-665
    • /
    • 2013
  • This research was conducted to investigate pollutant load unit factor from aquacultural farms. Pollutant load unit factors were investigated on the 13 kinds of fish type, i.e., Trout, Leather Carp, Eel, Carp, Cartfish, Freshwater Eel, Crucian Carp, Colored Carp, Sturgeon, Marsh Snail, Sweetfish, Pond Snail, Eriocheir Sinensis. Water qualities in aquacultural farms were investigated wide range of values by fish type and pollutant items. High BOD and COD values were observed at the Leather Carp (Ponded water system), Cartfish (Ponded water system) and Freshwater Eel (Recirculating System). TOC and DOC values were relatively high at the Freshwater Eel (Recirculating System) and Eriocheir Sinensis (Extensive). Eel (Ponded water system) and Freshwater Eel (Recirculating System) produced high concentrated nutrient pollutants, i.e., T-N, T-P. Pollutant load unit factors are dependent on fish type, aquacultural type, water quality items, etc. If some fishes have similar basic unit values, those could be applied for TMDLs as a group of fish having same pollutant load unit. The water quality concentrations of post treatment facilities' (mainly reservoir tank) effluent were higher than those of fish raising bath because of extracting pollutant from sediment in the reservoir tank. Therefore, it needs to the management and regulations about post treatment facilities.

Safer Zone Analysis for Multiple Investment Alternatives on the Total-Cost Unit-Cost Domain

  • Kono, Hirokazu
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.1
    • /
    • pp.11-17
    • /
    • 2012
  • Along with the recent trend toward increasing variety and shorter life of products in the market, evaluation of risk for economic investment alternatives is of practical importance in manufacturing companies. This paper assumes that each alternative is composed of demand volume and unit sales price as income factors, and unit variable cost and fixed cost as expense factors. The paper assumes that these four factors move worse from the originally expected values, toward the direction of decreasing profit. Values of these four factors are also assumed to fluctuate from year to year over the entire multi-period. By applying the analysis of the breakeven points to each of the four factors, safer area against these changes is represented on the two dimensional domain called normalized total-cost unit-cost domain. A practical numerical example is analyzed to verify the validity of the proposed method.

Effects of Dietary illite As a Feed Additive on The Haugh Unit and Fatty Acid Profiles of Eggs (일라이트(illite)를 산란계 사료에 첨가 시 계란 신선도와 지방산 조성에 미치는 영향)

  • Choi, In-Hag
    • Journal of Environmental Science International
    • /
    • v.28 no.9
    • /
    • pp.807-811
    • /
    • 2019
  • The present study aimed to examine the effects of dietary illite as a feed additive on the Haugh unit and fatty acid profiles of eggs. One hundred and twenty laying hens (48-week-old Hy-line Brown) were randomly assigned to one of the following two treatments: control or 2% illite powder. At 2 and 4 weeks, the Haugh unit values between the control and 2% illite powder groups were not significantly different (p>0.05). In addition, individual fatty acid content at 2 and 4 weeks did not differ between the treatments (p>0.05), except for palmitic (C16:0) and palmitoleic acid (C16:1) content. The addition of 2% illite powder caused no difference between the total saturated and total unsaturated fatty acids at 2 and 4 weeks (p>0.05). In conclusion, the addition of dietary illite at a rate of 2% did not improve the Haugh unit values or fatty acid profiles of eggs.

Unit Loads of Pollutants in a Paddy Fields Area with Large-Scaled Plots during Irrigation Seasons (관개기 대구획 광역논에서의 오염부하 원단위)

  • 오승영;김진수;김규성;김선종;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.136-147
    • /
    • 2002
  • Characteristics of unit loads of pollutants were investigated at a paddy fields area(Soro-ri) with large-scaled plots on loam soil during irrigation seasons of 1999 ∼2000. The average irrigation requirement of experimental paddy area are estimated at over 3,000 mm. The unit loads of pollutants in paddy fields area are determined by subtracting irrigation water load from outflow load (percolated and surface outflow loads). Surface outflow load in rainy days was calculated using the relationships of discharge and load, which are grouped into fertilizing and non-fertilizing periods. The ratios of the surface outflow load in rainy days to the total surface outflow load are 16.4% for T-N, 26.8% for T-P, and 23.3% far CODc,. The unit loads of pollutants show month-to-month and year-to-year variations, and monthly unit load of pollutants can show negative values, indicating that the paddy area acts as the pollutants sink. The average unit loads of the pollutants during irrigation seasons were estimated at 18.2 kg/ha fur T-N, 0.31 kg/ha for T-P, and 43.3 kg/ha for CODc,, which are smaller than the reported values for Kosei area in Japan.

A Research on a Revised Application of Unit Hydrograph Variant According to Rainfall Intensity in a Rainstorm (호우사상의 강우강도에 변동하는 단위유량도의 보완적 적용에 관한 고찰)

  • Yoo, Ju-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • This study is a research based on an existing analysis that peak values of unit hydrograph are variant according to rainfall intensity in a watershed. Differently from the fundamental assumption that an unit hydrograph is time-invariant in a watershed a variant unit hydrograph to rainfall intensity by storms is defined and applied into rainfall events, which produces out runoff hydrograph for an examination. Peak flow and time to peak of unit hydrograph used for an application are obtained from the relation equation with rainfall intensity developed by a previous study reviewed, and its shape is made by Nash unit hydrograph which is determined by the peak values. For the purpose of a comparison an invariant unit hydrograph is defined as Nash model obtained from averaged peak values of unit hydrograph which is derived by 26 rainfall storms. Peak flow and time to peak of flood hydrograph developed respectively by variant unit hydrograph with rainfall intensity and an averaged unit hydrograph are compared to those of the observed hydrograph. With comparing both hydrographs calculated by averaged unit hydrograph and revised unit hydrograph to observed hydrograph it is shown the peak flow and time to peak of hydrograph calculated by time-invariant unit hydrograph revised in this study are closer to those of observed hydrograph than those calculated by averaged unit hydrograph.

3T DWIs with Different b-Values in Brain Tumors

  • 김대진;장기현;송인찬;권배주;한문희
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.24-24
    • /
    • 2003
  • Purpose: It is known that diffusion-weighted MR imaging (DWI) is helpful in the evaluation of malignancy grading in brain tumor. This study was to evaluate the DWls with different b-values of various brain tumors in order to determine optimal b-values on 3T MR unit. Method: On a 3T MR unit, DWls with b-values of 1, 000, 3, 000 and 5, 000 s/mm2 were obtained in 20 patients of pathologically-proven brain tumors (7 metastases, 4 high grade gliomas, 2 Iymphomas, 2 low grade gliomas, 2 germinomas, and one each of germinoma, meningioma, hemangioblastoma and central neurocytoma. The overall image quality, contrast between normal brain parenchyma and tumor and signal intensities of solid and cystic components were comparatively evaluated among DWls with different b-values by visual inspection.

  • PDF