• Title/Summary/Keyword: Unit Testing

Search Result 616, Processing Time 0.023 seconds

Fabrication and Evaluation Properties of Micro-Tubular Solid Oxide Fuel Cells (SOFCs) (마이크로 원통형 SOFC 제작 및 특성평가)

  • Kim, Hwan;Kim, Wan-Je;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.749-753
    • /
    • 2012
  • In present work, anode support for micro-tubular SOFC was fabricated with outer diameter of 3 mm and characterized with microstructure, mechanical properties and gas permeability. The microstructure of surface and cross section of a porous anode support were analyzed by using SEM (Scanning Electron Microscope) image. The gas permeability and the mechanical strength of anode support was measured and analysed by using differential pressure at the flow rates of 50, 100, 150 cc/min. and using universal testing machine respectively. The unit cell composed of NiO-YSZ, YSZ, YSZ-LSM/LSM/LSCF was fabricated and operated with reaction temperature and fuel flow rate and showed maximum power density of $1095mW/cm^2$ on the condition of $800^{\circ}C$. The performance of single cell for micro-tubular SOFC increased with the increasing the reaction temperature due to the decrement of ohmic resistance of cell by the increment of the ionic conductivity of electrolyte through the evaluation of electrochemical impedance analysis for single cell with reaction temperature.

Study on Characteristics of Controlled Low Strength Material Using Time Domain Reflectometry (시간영역반사법을 이용한 유동성 채움재의 특성 연구)

  • Han, Woojin;Lee, Jong-Sub;Byun, Yong-Hoon;Cho, Samdeok;Kim, Juhyong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.4
    • /
    • pp.33-37
    • /
    • 2016
  • The hydration process of Controlled Low Strength Material (CLSM) used for backfill is the primary factor to determine the construction period. The objective of this study is to monitor the hydration process of CLSM using the Time Domain Reflectometry (TDR) and to establish the relationship between dielectric constant and compressive strength. The CLSM specimen is composed of cement, flyash, silt, sand, accelerator, and water. The material characteristics of the CLSM including flow, unit weight, compressive strength are investigated. To measure the dielectric constant of the CLSM during the curing time, TDR probe incorporated with a mold and a reflectometer are used. Experimental results show that the dielectric constant remains constant at early stage, and then decreases as the curing time increases. In addition, the dielectric constant is related to the compressive strength in inverse power function. This paper suggests that the TDR technique may be used as a non-destructive testing method in order to estimate the compressive strength of the CLSM mixture under construction.

The Development of Econometric Model for Air Transportation Demand Based on Stationarity in Time-series (시계열 자료의 안정성을 고려한 항공수요 계량경제모형 개발)

  • PARK, Jeasung;KIM, Byung Jong;KIM, Wonkyu;JANG, Eunhyuk
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.1
    • /
    • pp.95-106
    • /
    • 2016
  • Air transportation demand is consistently increasing in Korea due to economic growth and low cost carriers. For this reason, airport expansion plans are being discussed in Korea. Therefore, it is essential to forecast reliable air transportation demand with adequate methods. However, most of the air transportation demand models in Korea has been developed by simple regression analysis with several dummy variables. Simple regression analysis without considering stationarity of time-series data can bring spurious outputs when a direct causal relationship between explanatory variables and dependent variable does not exist. In this paper, econometric model were developed for air transportation demand based on stationarity in time-series data. Unit root test and co-integration test are used for testing hypothesis of stationarity.

Physical Properties Related to Metamorphic Grade of the Hornfels Exposed Around Mt. Palgong (팔공산 주변 혼펠스의 변성도에 따른 물리적 특성)

  • Shin, Kuk-Jin;Oh, Je-Heon;Jung, Yong-Wook;Kim, Gyo-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.5
    • /
    • pp.25-35
    • /
    • 2014
  • The sedimentary rocks exposed around Mt. Palgong were subjected to metamorphism due to a granitic magma intrusion at late Cretaceous, and they eventually metamorphosed to hornfels by the action of both hydrothermal solution and high temperature supplied from the magma. The hornfels zone around the granite body ranges from 2.0 to 3.5 km in width but the boundary between hornfels and sedimentary rocks is not obviously defined because the metamorphic grade gradually decreases with distance from the granite boundary. A series of laboratory tests on 350 core specimens made by 35 fresh rock blocks obtained from 5 selected locations around Mt. Palgong are performed to verify the variation of physical and mechanical properties related to metamorphic grade of the rock. Water content and absorption ratio of the hornfels linearly increase with distance to the granite boundary whereas dry unit weight, p-wave velocity, point load strength, and slake durability index linearly decrease with the distance. These results imply that the metamorphic grade of the hornfels also linearly decrease with the distance to granite boundary. Empirical equations for the variation of properties with the distance to granite boundary and relationship between a property and another one are deduced by regression analyses. And a criteria for classification of hornfels exposed in the study area based on the P-wave velocity and point load strength is proposed.

Confirmatory Analysis of Perception and Preference Scales for Work Characteristics among Korean Nurses (중환자실 근무환경 특성에 대한 간호사의 인지도와 선호도 도구 검증)

  • ;;Barbara Daily
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.215-224
    • /
    • 1999
  • The study was conducted to centum the construct of individual perception and preference for work characteristics as personal factors influencing Korean nurses' job satisfaction. The subjects of the study were 231 nurses who are currently working in intensive care units and have been for a minimum of 6 months. The study used the Staff Perception and Preference Scale(Song et al., 1997) to measure the individual's perception and preference on the technical. practice. and management components of the ideal work environment. The Korean version of the Staff Perception and Preference Scale consists of 16 items on perception and 13 on preference with each item related on a scale from 1(not at all) to 4(a great deal). Psychometric testing revealed that the preference and perception scale is internally consistent with Chronbach's alphas of .83 for perception scale arid .80 for preference scale. The subscales of the perception and preference scale also showed acceptable reliability for the early stage of the development of the instruments with Chronbach alphas of .62-.76 and .69-.83 respectively. Criterion-related validity of the scale was tested by examining correlations with individual growth need that is conceptually close to individual preference. but not to individual perception. Individual growth need was significantly related to individual preference(r=.63, p<.05), but the correlation with the perception scale was not significant. A separate factor analysis for the each of perception and preference scales was performed with a three-factor loading solution based on a previous study. The results on the staff perception scale confirmed with varimax rotation that the items were cleanly and strongly loaded on technique. practice and management components, which together explained 50.7% of the variance. The factor analysis on the staff preference scale also yielded a three factor solution that explained 56.7% of the variance. but items on technique and management components were loaded together. This phenomena may due to the current nursing delivery system in Korea where nurses never experience either shared governance nor case management, and as a results they may not be able to consider management roles as their potential extended roles. Therefore, more efforts should be given to enhance nurses' autonomy and decision making in the technique, practice and management components of their work environment. Meanwhile, there is a need for continuously confirming and developing tools for individual perception and preferences to effectively enhance job satisfaction among Korean nurses through innovative work environments.

  • PDF

A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study (3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.253-259
    • /
    • 2015
  • The information of contrast media concentration on target organ is very important to get reduce the side effect and high contrast imaging. We investigated alternation of signal intensity as a function of the modality of Gd-based contrast media on spin echo and ultra short time echo (UTE) of T1 effective pulse sequence at 3T MRI unit. Gadoxetic acid, which is a MRI T1 contrast medium, was used to manufacture an agarose phantom diluted in various molarities, and sterile water and agarose 2% were used as the buffer solution for the dilution. The gold standard T1 calculation was based on coronal single section imaging of the phantom mid-point with 2D Inversion recovery spine-echo pulse sequence MR imaging for testing of phantom accuracy. The 1-2mmol/L and 7mmol/L was shown the maximum signal intensity on spin echo and UTE respectively. We confirm the difference of contrast media concentration which was shown the maximum signal intensity depending on the T1 effective pulse sequence.

A Fundamental Study of Ferro Copper Slag for Concrete Aggregate (동슬래그의 콘크리트용 골재 활용에 관한 기본연구)

  • Song, Tae-Hyeob;Lee, Mun-Hwan;Lee, Sea-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • To use ferro copper slag as aggregate in the construction, an evaluation upon the two kinds of ferro copper slag being produced was conducted to determine the basic physical, and mechanical properties, chemical component and environmental noxiousness. As a result of experiment, it was found that two kinds of ferro copper slag satisfies the physical and mechanical properties of aggregate, prescribed in KS F 2526, and that in the result of noxious heavy metal eruption test by single bach extraction, no eruption of noxious heavy metal was detected or the eruption was far below the reference value. And mortar test was conducted by replacing sand of 25, 50, 75, 100% and the performance level was presented upon reviewing the fluidity property and variable aspects of unit weight. The increase of strength in accordance with replacement rate of sand was found to be the below than the equivalent level compared to the testing specimens that did not use ferro copper slag, but those of 25% replacement rate was above than 0%. Thus, two kinds of ferro copper slag, produced in the domestic, were found to be possessing the enough physical properties to use as concrete aggregate assuming that used with sand and in particular, it was reviewed to be advantageous in manufacturing concrete or mortar that requires weight.

EFFECTS OF VARIOUS CEMENTS AND THERMOCYCLING ON RETENTIVE STRENGTHS OF CEMENTED IMPLANT-SUPPORTED PROSTHESES (시멘트 유지형 임플란트 보철물의 유지력에 시멘트의 종류와 열순환이 미치는 영향에 관한 연구)

  • Cho Jae-Ho;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.466-475
    • /
    • 2003
  • Statement of problem : In cemented implant-supported porstheses, it is still controversy what kind of cement to use. However, the effect of thermocycling on retentive strength of cemented implant-supported prostheses has not been well investigated. Purpose : This study was tested to evaluate the effects of various cements and thermocycling on retentive strengths of cemented implant-supported prostheses. Material and methods : Prefabricated implant abutments, height 5mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were used. Ten specimens of two-unit fred partial denture were fabricated. The luting agents used for this study were three provisional luting agents which were Temp bond, Temp bond NE, IRM and four permanent luting agents which were Panavia F, Fuji-cem, Hy-bond Zinc cement, Hy-bond Polycarboxylate cement. 24 hours after cementation. the retentive strengths were measured by the universal testing machine with a cross-head speed of 0.5mm/min. Then cementation procedures were repeated and specimens were thermocycled 1000 times at temperature of $5^{\circ}C$ and $55^{\circ}C$. After thermocycling, the retentive strengths were measured. Results : Before thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem. Hy-bond Zinc cement. Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were significant differences among each groups(p<0.05). After thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem, Hybond Zinc cement, Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were no significant differences among Panavia F, Fuji-cem and Temp bond NE, Temp bond(p>0.05). The retentive strengths before and after thermocycling showed significant differences in Hy-bond Zinc cement. IRM, Temp bond NE and Temp bond(p<0.05). Conclusion : Within the limitation of this study, thermocycling do not affect the retentive strengths of permanent luting agents but the retentive strengths of temporary cements were reduced significantly after thermocyling.

Psychometrics of Task Self-Efficacy Scale for Korean Elderly (노인의 일상활동수행에 대한 자기효능척도의 신뢰도 및 타당도 평가)

  • ;;;;Beverly L. Roberts
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.831-842
    • /
    • 1997
  • The purpose of the study was to test the reliability and validity of the Korean version of Task Self-Efficacy Scale for activities of dally living (ADL). The Task Self-Efficacy Scale was developed by Roberts(1996) for low-intensity exercise study with older people to predict their performance of ADL. The scale was translated and back translated by bilingual persons, and then was modified to resolve variations in the translations. The Korean version of Self-Efficacy Scale for ADL was then administered to 193 elderly people including 95 hospitalized patients and 98 outpatients or healthy people. Face to face interview was used to fill out the structured questionnaire, and each interview took approximately 30 minutes. The subjects for the study were 80 women and 112 men with an age range of 65 to 95 years(M=71 years) of whom 82.6% classified themselves as moderate or quite active Most subjects(80.2%) had an education level of elementary school or less. The Self-Efficacy Scale for ADL is measured on a 0 to 10 VAS, assessing three areas of ADL : self care activities, household tasks, and motor tasks. The higher the score is, the higher person's confidence in performing ADL. Psychometric testing revealed that the scale was found to be internally consistent, showing a Cronbach's alpha of .97 The scale was significantly correlated with subjects' level of activity and subjective assessment of their health status. Moderate correlation with health-related hardiness scale also supported the validity. Factor analysis was performed to confirm whether the scale represents the three sub-areas as suggested in the literature. The results of the factor analysis led to a three factor solution according to Kaiser's criterion, but the items were not strongly and cleanly loaded for the third factor. This can be explained in that, among the three sub-ADL areas of the self-efficacy scale, the areas of self care activities and household tasks seem to have similar levels of difficulty in performance with not enough differences for the self-efficacy scale to distinguish between the two areas. Therefore, one factor solution was suggested since ADL can be seen as a unit of activities at similar level of difficulty in performance. One factor solution explained 68.1% of variance of the 19-item scale and all items were correlated over .6 with the factor, showing that the selected factor solution fits the model. The results indicated that the Korean version of Task Self-Efficacy Scale for ADL was reliable and valid in producing useful information to evaluate the effects of various interventions toward promoting health and quality of life for elderly people.

  • PDF

Autosomal-dominant Polycystic Kidney Disease in a Family of Scottish Fold Cats (스코티쉬 폴드 고양이 가족에 발생한 상염색체 우성 다낭성 신병)

  • Seo, Kyoung-Won;Kim, Sae-Um;Ahn, Jin-Ok;Coh, Ye-Rin;Han, Sung-Young;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.726-728
    • /
    • 2010
  • Autosomal-dominant polycystic kidney disease (AD-PKD) is common in Persian and Persian-related breeds, and is sporadically reported in Scottish Fold cats. A 5-year-old male Scottish Fold cat was diagnosed with polycystic kidney disease based on screening tests and abdominal ultrasonography and died 3.5 months after diagnosis. The cat had 14 kittens with three queens, including his female sibling, with an age range of 3 months to 8 years. Genetic testing to confirm the genetic transmission of AD-PKD which detects the mutated PKD1 gene was performed. Abdominal ultrasonography confirmed the presence of renal cysts. Nineteen cats were screened in the present study (13 males and 6 females), with an age range of 3 months to 8 years. The results of renal ultrasonography agreed with the genetic test results in the 19 cats in which both tests were performed and 8 cats were diagnosed as ADPKD based on these tests. AD-PKD has not been investigated in cats in South Korea. Moreover, this is the first report of AD-PKD in a family unit of Scottish Fold cats.