• Title/Summary/Keyword: Unit Testing

Search Result 620, Processing Time 0.029 seconds

Comparison of Egg Testing Devices for Internal Egg Quality Measurements (계란 할란검사장비의 성능 비교)

  • Kim, Dong Jun;Jeon, Seung Yob;Kim, Hee Won;Won, Jea Sun;Lee, Jae Cheong;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.229-233
    • /
    • 2016
  • This study was conducted to compare three commercially available egg testing devices for measuring egg quality. The devices used were a Laser-type (automatic), a Ultrasonic-type (automatic), and a Probe-type (manual). Fresh eggs weighing 60~68 grams were obtained from a commercial hen farm. Three trials were conducted. In Trial 1, a total of 50 eggs were successively analyzed by the three egg testing devices. In Trial 2, fresh eggs were successively analyzed by a combination of two egg testing devices. In Trial 3, a total of 600 eggs (weighing 60~68 grams) laid by same flock were selected, further divided into three sub-groups with a total of 200 eggs, and analyzed by an egg testing device. In Trials 1 and 2, no apparent difference was observed in egg weight between egg testing devices. However, albumin height was scored highest in the Ultrasonic-type egg tester followed by the Probe-type and Laser-type (Trials 1 and 2). Consequently, the Haugh unit was similarly altered. Yolk color was highest in the Laser-type egg tester followed by the Ultrasonic-type and Probe-type (Trials 1 and 2). When fresh eggs laid by a single flock were independently analyzed by three devices, egg weight did not differ, but albumin height and Haugh unit were higher (p<0.05) in the Ultrasonic-type egg tester than in the Probe-type or Laser-type testers. However, Laser-type testers produced higher (p<0.05) yolk color values than the Ultrasonic-type or Probe-type egg testers. In conclusion, the commercially available egg testing devices exhibited performance differences in measuring egg qualities, which warrants further consideration as to whether the magnitude of bias and precision between the devices could be acceptable in the egg grading system, especially when assessing eggs stored for certain durations.

Evaluation of Near/Far Field and Directivity of Ultrasonic Transducer for Turbine Rotor Disc (터빈 로타 디스크의 초음파탐상을 위한 초음파탐촉자의 지향성 및 탐상범위)

  • Won, S.H.;Chang, H.K.;Cho, K.S.;Lee, J.O.;Lee, J.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.163-171
    • /
    • 1998
  • Near/far field length and directivity of transducers were investigated for the improvement and evaluation of the detectability of flaws in a disc. The reference block is fabricated for the disc of stage 6 in Yonggwang unit 1. The near/far field and directivity of an ultrasonic transducer with the center frequency of 5MHz were calculated for the inspection of the disc. These values showed good agreements with the experimental results. In the system composed of a wedge and a disc, those are evaluated theoretically and experimentally for the specimen with the artificial flaws of the size 2mm and 4mm and an ultrasonic transducer with the center frequency 5MHz and diameter 0.5inch. The detectability of keyway-flaw and detectable region for inspection were evaluated by using both tangential $45^{\circ}$ and $90^{\circ}$ transducers located at the distance of 53mm and 75mm from the disc hub, respectively.

  • PDF

Energy analysis-based core drilling method for the prediction of rock uniaxial compressive strength

  • Qi, Wang;Shuo, Xu;Ke, Gao Hong;Peng, Zhang;Bei, Jiang;Hong, Liu Bo
    • Geomechanics and Engineering
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • The uniaxial compressive strength (UCS) of rock is a basic parameter in underground engineering design. The disadvantages of this commonly employed laboratory testing method are untimely testing, difficulty in performing core testing of broken rock mass and long and complicated onsite testing processes. Therefore, the development of a fast and simple in situ rock UCS testing method for field use is urgent. In this study, a multi-function digital rock drilling and testing system and a digital core bit dedicated to the system are independently developed and employed in digital drilling tests on rock specimens with different strengths. The energy analysis is performed during rock cutting to estimate the energy consumed by the drill bit to remove a unit volume of rock. Two quantitative relationship models of energy analysis-based core drilling parameters (ECD) and rock UCS (ECD-UCS models) are established in this manuscript by the methods of regression analysis and support vector machine (SVM). The predictive abilities of the two models are comparatively analysed. The results show that the mean value of relative difference between the predicted rock UCS values and the UCS values measured by the laboratory uniaxial compression test in the prediction set are 3.76 MPa and 4.30 MPa, respectively, and the standard deviations are 2.08 MPa and 4.14 MPa, respectively. The regression analysis-based ECD-UCS model has a more stable predictive ability. The energy analysis-based rock drilling method for the prediction of UCS is proposed. This method realized the quick and convenient in situ test of rock UCS.

A New IgG Immunoblot Kit for Diagnosis of Toxoplasmosis in Pregnant Women

  • Khammari, Imen;Saghrouni, Fatma;Lakhal, Sami;Bouratbine, Aida;Said, Moncef Ben;Boukadida, Jalel
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.5
    • /
    • pp.493-499
    • /
    • 2014
  • The determination of the accurate immune status of pregnant women is crucial in order to prevent congenital toxoplasmosis. Equivocal results with conventional serological techniques are not uncommon when IgG titers are close to the cut-off value of the test, so that a confirmatory technique is needed. For this purpose, we developed a homemade immunoblot (IB) using soluble extract of Toxoplasma gondii tachyzoites and assessed it by testing 154 positive, 100 negative, and 123 equivocal sera obtained from pregnant women. In order to select the more valuable bands in terms of sensitivity and specificity, we used the Youden Index (YI). The highest YIs were those given by the 32, 36, 98, 21, and 33 bands. The simultaneous presence on the same blot of at least 3 bands showed a much higher YI (0.964) and was adapted as the positivity criterion. The analysis of results showed that our homemade IB correlated well with the commercial LDBIO Toxo II $IgG^{(R)}$ kit recently recommended as a confirmatory test (96.7% of concordance).

Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF

A Restructuring Technique of Legacy Software Systems for Unit Testing (단위테스트를 위한 레거시소프트웨어시스템의 재구성 기법)

  • Moon, Joong-Hee;Lee, Nam-Yong
    • The KIPS Transactions:PartD
    • /
    • v.15D no.1
    • /
    • pp.107-112
    • /
    • 2008
  • The maintenance of legacy software systems is very important in the field of a software engineering. In the maintenance, a regression test confirms the behavior preserving of the software which has been changed but most of regression tests are done in a system level and rarely done in a unit test level because there is no test case. This paper proposes how to modify legacy software systems and make unit test cases as an asset. It uses a technique with a specific module of a real software development project and analyzes test coverage results. After this, if a study about automatic restructuring techniques and a test case generation proceeds continuously, we can expect the big advance of legacy software systems maintenance.

Transmission Effect of Price Variations (가격변동의 전이효과)

  • Kim, Tae-Ho;Ann, Ji-Hee
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.2
    • /
    • pp.241-253
    • /
    • 2010
  • As standard unit root tests are empirically proved to fail to reject the null hypothesis of a unit root for many economic and business time series, it is doubtful that most of those series are informative about the existence of a unit root or that those tests are powerful against relevant alternative hypotheses. This study attempts to perform tests of the null hypothesis of stationarity as well as tests of the null hypothesis of a unit root using the time series data of housing prices in the major metropolitan areas. The results of the additional analyses such as lead-lag, cross-correlation and impulse response for testing the statistical interrelationships between the prices are generally found to be consistent.

A study of aerobic and anaerobic inducible genes using Mu dJ(Km lac) operon fusion in salmonella typhimurium (Salmonella typhimurium에서 Mu dJ(Km lac) operon fusion을 이용한 산소, 무산소 유도 유전자에 관한 연구)

  • 김종선;우영대;박종희;김영권;이인수;박용근
    • Korean Journal of Microbiology
    • /
    • v.27 no.3
    • /
    • pp.201-209
    • /
    • 1989
  • Using Mu dJ(Km lac) operon fusion, several oxygen-regulated genetic loci were identified in Salmonella typhimurium. Nine aerobically inducible(oxi) and thirteen anaerobically inducible(ani) operon fusions were newly identified. Based on the control by oxrA regulatory locus, the ani-lacZ fusions were grouped into two classes: class I loci were regulated by oxrA regulatory locus; class II genes were not affected by this locus. Some of the ani-lacZ fusions had required growth in CAA and LB before they exhibited the inducible phinotype. Most of all ani-lacZ fusions were repressed by nitrate and fumarate. Three of the ani loci were mapped into $59{\pm}0.14$ map unit (YK114), $64{\pm}0.5$ map unit(YK120), and $93{\pm}0.29$ map unit(YK112) by testing the cotransduction frequency, respectively.

  • PDF

A Study on Architecture of Test Program based UML (UML 기반 점검 프로그램 설계 방법에 관한 연구)

  • Kim, ByoungYong;Jang, JungSu;Ban, ChangBong;Lee, HyoJong;Yang, SeungYul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.217-230
    • /
    • 2012
  • This paper propose interacting test programming methods between test equipment and hardware unit to verify function and performance of the hardware unit under test. Proposed test program can minimizes the risk of failures when the unit is mounted on the aircraft by testing and verifying the unit under the worst stress condition. Also, Object oriented design using UML make it easy to apply in other equipments. Test program consists of architecture package and hardware package. Architecture package is in a role for system management, log analysis, message receiving and message analysis. Messages that are used by system management define messages for testing and defined messages is sent and received to test equipment through Ethernet. Hardware package is in a role for hardware management that is needed to be tested and is related to a system. Hardware to be tested is divided into internal test and transmission test. Internal test inspects hardware itself and reports the test results to the test equipment. Transmission test inspects communication device by sending or receiving data. All kinds of test is done in the worst condition of the test unit executing in parallel. Each device is tested at least 482 times and at most 15,003 times about one hour. Test program is utilized in hardware reliability test like as environmental test or EMI test.

An Investigation of Fracture Mechanism of Spheroidal Graphite Cast Iron by Acoustic Emission Method (AE방법에 의한 구상화흑연(球狀化黑鉛) 주철재의 파괴기구 구명(究明))

  • Kim, S.C.;Ham, K.C.;Oh, B.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.2
    • /
    • pp.17-36
    • /
    • 1987
  • In this experimental research, fracture mechanisms of spheroidal graphite cast iron (As Cast, annealed and normalized) were investigated by using Acoustic Emission (AE) technique. In this study, the data (AE signal) are digitized and processed with the 8 bits micro-computer (APPLE II) connected to the AE measuring device without data processing unit. The source of AE signal was estimated by fractography analysis. The results obtained in this experimental study are summarized as follows : For the heterogeneous materials (spheroidal graphite cast iron) with inclusions which may considered as cracks, it is found that low and high AE amplitude appear simultaneously and the load is found to be fluctuated in the final stage of deformation. But the lad is not fluctuated in tension test with low AE amplitude only. AE is measured within elastic region and it is confirmed that 0.2% offset yield load agrees approximately with the load point where AE counts decrease steeply after the point of maximum AE counts.

  • PDF