• Title/Summary/Keyword: Unit System

Search Result 8,828, Processing Time 0.042 seconds

A Study on the Hydraulic Brake Application of Electrical Multiple Unit (전동차에 유압제동장치 적용방안 연구)

  • Lee Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1355-1357
    • /
    • 2004
  • The hydraulic brake system is recently apply to the AGT system such merit as installation is convenient and brake force is stronger than pneumatic brake system. The hydraulic brake system consist of brake operating unit, electronic control unit, air compressor and pneumatic/hydraulic tranducer. The components of it are controlled and designed to perform the function of brake system. Therefore, This paper design and the hydraulic brake system and propose the derection of development for Urban Transit System.

  • PDF

A Study on Standard Unit Price Analysis of e-learning & Postal Distance Learning (인터넷 및 우편 원격 기관 훈련비용 기준단가 분석 연구 공학교육에 관한 연구)

  • Rha, Hyeon-Mi
    • Journal of Engineering Education Research
    • /
    • v.14 no.3
    • /
    • pp.61-71
    • /
    • 2011
  • Korea has introduced the levy-grand system in the vocational learning finance. The standard unit price system of training cost was utilized in the distribution of training budget and the reimbursement system including total or partial training cost return has been operated in the corporate training after completing the learning course particularly. The standard unit price was calculated in the base of analyzing on supporting budget by the government per training institutions and corporate payment decision to learning institutions. The proposing standard unit price system of training cost was analyzed in the current standard price unit of training cost and then an improvement policy and the implication are derived from it. At the result of this study, the current government supporting level to e-learning and postal distance learning indicates good status.

An Analysis on the Influence Factors relative to Reliability of Standard Production Unit System (표준품셈의 신뢰성에 대한 영향요인 분석)

  • Kim, Yong-Woo;Shin, Won-Sang;Son, Chang-Baek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.187-189
    • /
    • 2011
  • Standard production unit system has been used as accumulated standard for the cost estimation of public construction projects. However, it is difficult to estimate reasonable cost due to adaptation of a uniform standard and reflect changes in the technology. The purpose of this study is to provide basic data for improvement of standard production unit system through the identifying problems and analysing its influence on enactment and/or revision work of standard production unit system.

  • PDF

Development of the Integrated Monitoring System for Panel boards (분전반 통합 감시 시스템 개발)

  • Kim, Il-Kwon;Cho, Hyun-Kyung;Lee, Dong-Zoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.347_348
    • /
    • 2009
  • In this paper, we described the integrated monitoring system for low-voltage panel boards. This system consists of three parts, a panel board controller, an integrated monitoring unit and a remote PC. The panel board controller which was made of CT/PT unit, control unit and power supply is able to transmit variable parameter for monitoring and diagnosis of low voltage branch circuits. Also, the integrated monitoring unit was collected monitoring data from panel boards and displayed on the touch panel.

  • PDF

Unit Commitment Considering Variable Power of Hydro and Pumped Storage Hydro Units (수력 및 앙수발전기의 가변출력운전을 고려한 기동전지 계획에 관한 연구)

  • 송길영;이범;김용하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.351-362
    • /
    • 1994
  • This paper presents a new method for solving a long term unit commitment problem including hydro and pumped storage hydro units in a large scale power system. The proposed method makes it possible to get variable power of hydro and pumpde storage hydro units and results in the better unit commitment with good convergency. Moreover this paper proposes an unit commitment algorithm to consider variable power of these units effectively by Lagrangian Relaxation method. By applying the proposed method to the test system and the real system, it is verified the usefulness of this method.

A Study on the Analysis of Architectural Interior Space through Movement System focused on Hyangdan and Kwankajung (운동체계에 의한 건축공간 분석에 관한 연구 -향단과 관가정의 안채$\cdot$사랑채 실내공간분석 -)

  • Lee Kum-Jin;Choi Dong Hyeog
    • Journal of the Korean housing association
    • /
    • v.16 no.2
    • /
    • pp.55-65
    • /
    • 2005
  • 'Movement System' is made of the interaction of user and architectural spaces related to each other in order. 'Movement' meant in movement system is possible only in the status of user and architectural space together. Movement created and disappeared by the user is not subordinated to the existing architectural space but becomes the main element of formating movement system. It is required that movement conception applied to architecture should be derived from the essence of movement and this study presents the movement system. To explain the formating process of movement system, A. N. Whitehead's process philosophy theory is at the basis and transformed in architectural aspects. On basis of these theoretical backgrounds, the process of making movement system can be explained. There are unit movement, unit object, and elements for movement process as the basic requirements for movement system, each unit is apprehended by individual operation and the nexus is composed by associative operation of apprehended units. This nexus becomes the object of a new subject and forms multiple nexus. Relation of unit movement and unit object and nexus are apprehended as the continuation and extensive continuum is made. At that time, movement with multiple phases set inbetween systems and extended multiplied. Through above study, movement system is applied to Korean traditional houses.

Daily Unit Commitment Scheduling of Power System with Energy Storage System (전력저장장치를 고려한 일간 최적 기동정지계획 수립연구)

  • Song, Ha-Na;Jang, Se-Hwan;Kim, Hyeong-Jung;Roh, Jae-Hyung;Park, Jong-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.717-725
    • /
    • 2011
  • In the power system with an electric storage system that can increase utilization rate of the source of such new renewable energy, this paper introduces the approach on the daily unit commitment scheduling that determines simultaneously optimum operational condition and output of thermal generators and electric storage device. The unit commitment is one of the most important issues in economic operation and security of short-term operational plan of the power system. It is to determine on/off status of generator to minimize operational cost during the given period. The committed generator should satisfy various operational limitation such as estimated demand by system, spinning reserve condition within minimum operational cost. In order to determine on/off or charge/discharge/idle condition and output level of units and electric storage system, the MILP(Mixed Integer Linear Programming) is suggested. The proposed approach is the mixed method between LP(Linear Programming) and IP(integer programming) which seeks the value of real number and integer that maximize or minimize function objective within given condition. The daily unit commitment problem with the electric storage system is applied to MILP algorithm through linearization and formulation process. The proposed approach is applied to the test system.

Design and Implementation of High Power Source Measurement Unit (고 전력 Source Measurement Unit의 설계 및 제작)

  • Lee, Sang-Gu;Baek, Wang-Gi;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

Design of FPGA in Power Control Unit for Control Rod Control System (원자로 제어봉 구동장치 제어시스템용 전력제어기 FPGA 설계)

  • Lee, Jong-Moo;Shin, Jong-Ryeol;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.563-566
    • /
    • 2003
  • We have designed the power control unit which belongs to the power cabinet and controls the power supplied to Control Rod Drive Mechanism(CRDM) as a digital system based on Digital Signal Processor(DSP). The power control unit dualized as the form of Master/Slave has had its increased reality. The Central Process Unit(CPU) board of a power control unit possesses two Digital Signal Processors(DSPs) of the control DSP for performing the tasks of power control and system monitoring and the communication of the Control DSP and the Communication DSP. To accomplish the functions requested in the power control unit effectively, we have installed Field Programmable Gate Arrays(FPGAS) on the CPU board and have FPGAs perform the memory mapping, the generation of each chip selection signal, the giving and receiving of the signals between the power controllers dualized, the fault detection and the generation of the firing signals.

  • PDF

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.