• Title/Summary/Keyword: Unit Fraction

Search Result 345, Processing Time 0.035 seconds

A Field Application Case of Direct Ice Slurry Transporting System for District Cooling (지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례)

  • Yoo, Ho-Seon;Lee, Sang-Hoon;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.

Improvements in Design and Evaluation of Built-In-Test System (무기체계 정비성 향상을 위한 BIT 설계 및 검증 방안)

  • Heo, Wan-Ok;Park, Eun-Shim;Yoon, Jung-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.111-120
    • /
    • 2012
  • Built-In-Test is a design feature in more and more advanced weapon system. During development test and evaluation(DT&E) it is critical that the BIT system be evaluated. The BIT system is an integral part of the weapon system and subsystem. Built-In-Test assists in conducting on system and subsystem failure detection and isolation to the Line Replaceable Unit(LRU). This capability reduces the need for highly skilled personnel and special test equipment at organizational level, and reduces maintenance down-time of system by shortening Total Corrective Maintenance Time. During DT&E of weapon system the objective of BIT system evaluation is to determine BIT capabilities achieved and to identify deficiencies in the BIT system. As a result corrective actions are implemented while the system is still in development. Through the use of the reiterative BIT evaluation the BIT system design was corrected, improved, or updated, as the BIT system matured.

Effects of Chrysanthemum coronarium L. on the Thermotropic Behavior of DPPC Liposomal Membrane

  • Bae, Song-Ja;Noh, Ok-Jeong;Roh, Sung-Bae
    • Journal of Life Science
    • /
    • v.10 no.2
    • /
    • pp.27-32
    • /
    • 2000
  • To understand the effects of the fraction from Chrysanthemum coronarium L. (CC), we prepared five different types of samples, denoted here as CCMM, CCMH, CCMEA, CCMB and CCMA. We studied the effects of these samples on the phase transition of liposomal membranes by high-sensitivity differential scanning calorimetry (nano-DSC). We used dipalmitoylphosphatidylcholine (DPPC) bilayers which make most stable liposomes among the other phosphatidylcholines. When the samples were added to the bilayers, the phase transition temperatures of DPPC liposomes incorporated with CCMH and CCMEA were decreased by 1.5 and 2^{\circ}C$, while the other three fractions showed less tendencies. The CCMH and CCMEA fractions markedly affected the thermotropic properties of DPPC liposomes, broadened and shifted the thermograms of DSC. It also significantly reduced the size of cooperative unit of the transition. In all cases, there was no change in enthalpy of transition within the concentration range of the CC fractions studied. We concluded that the incorporation of the CCMH and CCMEA into DPPC liposomes was preferentially located in the hydrophobic core of DPPC bilayers compared to the other three fractions CCMM, CCMB and CCMA. These results suggest that certain substances in CCMH and CCMEA fractions might have biologically significant effects on the fluidity of biological membrane.

  • PDF

Process Analysis and Simulation for System of Air Liquefaction Separation Using LNG Cold Energy (LNG 냉열을 이용한 공기액화분리시스템의 시뮬레이션 및 공정 해석)

  • HAN, DANBEE;BAEK, YOUNGSOON
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.3
    • /
    • pp.276-281
    • /
    • 2019
  • The process of separating oxygen and nitrogen from the air is mainly performed by electric liquefaction, which consumes a lot of electricity, resulting in higher operating costs. On the other hand, when used for cold energy of LNG, electric power can be reduced compared to the electric Linde cycle. Currently, LNG cold energy is used in the cold refrigeration warehouse, separation of air-liquefaction, and LNG cold energy generation in Japan. In this study, the system using LNG cold energy and the Linde cycle process system were simulated by PRO/II simulators, respectively, to cool the elevated air temperature from the compressor to about $-183^{\circ}C$ in the air liquefaction separation process. The required amount of electricity was compared with the latent heat utilization fraction of LNG, the LNG supply pressure, and the LNG cold energy usage. At the air flow rate of $17,600m^3/h$, the power source unit of the Linde cycle system was $0.77kWh/m^3$, compared with $0.3kWh/m^3$.

Feldstein-Horioka Puzzle in Thailand and China: Evidence from the ARDL Bounds Testing

  • RUANKHAM, Warawut;PONGPRUTTIKUL, Phoommhiphat
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.9
    • /
    • pp.1-9
    • /
    • 2021
  • This study aimed to investigate the existence of the Feldstein-Horioka (1980) puzzle in international macroeconomics by applying the conditional Autoregressive Distributed Lag (ARDL) model to examine the long-run relationship between national savings and investments in Thailand and China. The input of this study relied on annual national savings and investments as a fraction of GDP during 1980-2019 which was collected from China National Bureau of Statistics (NBS) and Thailand National Economic and Social Development Council (NESDC). Hypothetically, Augmented Dickey-Fuller (ADF) and Phillips-Perron (PP) unit root tests were applied to test the stationary properties and to investigate the integration level of selected time series. The empirical results, confirmed by cumulative sum (CUSUM) and cumulative sum square (CUSUMSQ), maintained no serial correlation and structural break problems. The finding of this study suggested that the Feldstein-Horioka puzzle in Thailand did not exist significantly. Thailand's national savings and investments nexus was independent, following the classic economic idea that financial liberalization, or perfect capital mobility, allowed national savings and investments to flow freely to countries with better interest rates. Whereas, a strong significant correlation was found in the case of China during the fixed exchange rate regime switching in 1994 and post WTO participation after 2001-2019.

Delta Neutrophil Index as an Early Marker of Sepsis in Burn Patients (화상환자에서 패혈증의 조기 예측인자로서의 DNI)

  • Kim, Chong Myung;Ha, Chul Min
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.38-44
    • /
    • 2019
  • Purpose: The immature granulocyte count has been reported to be a marker of infection and sepsis. The difference in leukocyte subfractions (delta neutrophil index, DNI) in ADVIA 2120 reflects the fraction of circulating immature granulocytes in the blood. This study evaluated the clinical utility of DNI as a severity and prediction marker in critically ill patients with burn sepsis. Methods: One hundred and sixty nine patients admitted to the burn care unit were studied. DNI (the difference in leukocyte subfractions identified by myeloperoxidase and nuclear lobularity channels) was determined using a specific blood cell analyzer. Results: Seventy one patients (42 %) were diagnosed with burn sepsis. DNI was significantly higher in patients with burn sepsis than in patients without (P<0.01). Delta neutrophil index was a better indicator of burn sepsis than C-reactive protein, lactate, white blood cell count, HCO3, base excess, lactate, procalcitonin (odds ratio, 6.31; confidence interval 2.36~16.90; P<0.01). And the receiver operating characteristic curves showed that delta neutrophil index, AUC 0.795 (95% confidence interval, 0.721~0.869; P<0.05) was a better predictor of burn sepsis than lactate, procalcitonin, white blood cell, base excess and abbreviated burn severity index. Conclusion: Delta neutrophil index may be used as a early marker of patients with burn sepsis.

An Experimental Study on the Effectiveness of Soil Compaction at Below-Freezing Temperatures (동결 온도에서 다짐효과에 관한 실험적 연구)

  • Hwang, BumSik;Chae, Deokho;Kim, Youngseok;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Korea has four distinct seasons, showing hot and humidity in summer and cold weather lasted in winter. Domestic research on earth work has been developed according to the seasonal characteristics, and most of research topics have focused on the effect of freezing-thawing on the performance of geo-materials. However, the previous research was performed on the ground compacted at room temperature and therefore, the effect of the sub-zero temperature at the time of construction was not fully investigated. The ground characteristics compacted at freezing temperature can be different from those at room temperature and show different characteristics of strength and deformation caused by freezing and thawing. Therefore, the compaction tests on sandy materials were conducted under various temperature at $-3^{\circ}C$ and $-8^{\circ}C$ with various fine contents of 0%, 5%, 10% and 15% in weight fraction. The effectiveness of soil compaction at below-freezing temperatures were compared with the compaction at room temperature at $18^{\circ}C$ in terms of the maximum dry unit weight and optimum water contents. Based on the test results, the maximum dry unit weight tends to decrease with the freezing temperature and the relative compaction at $-8^{\circ}C$ can not be satisfied with general specification standard.

Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients (회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거)

  • 박종안;허준무;손부순
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.132-140
    • /
    • 1998
  • Laboratory-scale experiments were conducted using a three-stage rotating biological contactor unit followed by lime precipitation and sedimentation with effluent recycle to the first stage. The purpose of this study was to evaluate the effects of hydraulic loadings of 0.031-0.076 $m^3/m^2/d and recycle ratio of 1 to 3 on the simultaneous removal of organics and nutrients from domestic wastewater. Lime was added to maintain pH of 10.4-11.0 in the coagulation-flocculation reactor. Results showed that the highest nitrogen removal rate of 70.5% occurred at the lower hydraulic loading of 0.031 $m^3/m^2/d at a recirculation rate of 300%, and similarly, highest nitrification occurred at the same hydraulic loading and recycle ratio. Concentration of ammonia nitrogen in the effluent was less than 1 mg/l at the same operating conditions for higher nitrogen removal. Whereas, high BOD and COD removal was observed at hydraulic loading rate of 0.054 $m^3/m^2/d, and high removal of organic matter was evident from the consistent low COD and BOD value. Results obtained from the operating condition of higher loading rate, 300% of recycle rate showed the highest removals. Increasing in recycle rate and hydraulic loading rate increased the volatile solids fraction of the sludges generated to the extent of 47% at 0.076 $m^3/m^2/d hydraulic loading and 300% recirculation rate. Since pH in the flocculator was maintained at the pH of 10.4-11.0, above 90% removal of phosphorus was obtained. Average concentration of suspended solids was always maintained over 40 mg/l in the effluent. Therefore an RBC unit operating at a hydraulic loading near 0.031 $m^3/m^2/d with a recycle rate of 300% is a viable and feasible alternate conditions to produce an effluent with relative low organic matter and phosphorus, provided that there is a neutralization unit to control the pH and SS of the effluent.

  • PDF

Antioxidant Activities of Solvent Fractions from Methanolic Extract of Cockscome (Celosia cristata L.) Flowers (맨드라미(Celosia cristata L.) 꽃 메탄올 추출물로부터 용매분획된 분획물의 항산화활성)

  • Kim, Hyun Young;Ko, Jee Yeon;Song, Seuk Bo;Kim, Jung In;Seo, Hye In;Lee, Jae Saeng;Kwak, Do Yeon;Jung, Tae Wook;Kim, Ki Young;Oh, In Seok;Jeong, Heon Sang;Woo, Koan Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.11
    • /
    • pp.1502-1507
    • /
    • 2012
  • The purpose of this study was to evaluate the antioxidant contents and activities of solvent fractions from methanolic extracts of cockscome flowers. The yield of methanolic extracts from cockscome flowers was 23.33%, whereas those of its solvent fractions (hexane, chloroform, ethyl acetate, butanol, and water) were 10.27, 20.00, 13.63, 17.55, and 38.54%, respectively. Total polyphenolic, flavonoid, tannin, and proanthocyanidin contents of methanolic extracts (ME) were 6.80 mg gallic acid equivalent (GAE)/g ME, 2.34 mg catechin equivalent (CE)/g ME, 6.23 mg tannic acid equivalent (TAE)/g ME, and $44.72{\mu}g$ CE/g ME, respectively. The highest total polyphenolic, flavonoid, and tannin contents of solvent fractions were 14.92 mg GAE/g solvent fraction (SF), 5.44 mg CE/g SF, and 13.38 mg TAE/g SF in the butanol fraction, respectively. The total proanthocyanidin contents were 42.47, 44.43, 50.03, 49.12, and $41.80{\mu}g$ CE/g SF, respectively. The DPPH and ABTS radical scavenging activities from cockscome flowers were 5.24 and 10.70 mg Trolox equivalent (TE)/g ME, respectively. The highest DPPH and ABTS radical scavenging activities of the solvent fractions were 12.53 and 21.09 mg TE/g SF in the butanol fraction, respectively. SOD-like activities of methanolic extracts from cockscome flowers were 7.96 units/mL, whereas those of its solvent fractions were 4.56, 6.15, 8.07, 12.36, and 5.21 units/mL, respectively. The results of this study show that notable antioxidant activities in cockscome flowers have significant health benefits.

CT Based 3-Dimensional Treatment Planning of Intracavitary Brachytherapy for Cancer of the Cervix : Comparison between Dose-Volume Histograms and ICRU Point Doses to the Rectum and Bladder

  • Hashim, Natasha;Jamalludin, Zulaikha;Ung, Ngie Min;Ho, Gwo Fuang;Malik, Rozita Abdul;Ee Phua, Vincent Chee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5259-5264
    • /
    • 2014
  • Background: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT). Materials and Methods: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose ($D_{Max}$) to rectum was the highest recorded dose at one of these five points. Using the HDRplus 2.6 brachyhtherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded ($D_{2cc}$) for all individual fractions. The mean $D_{2cc}$ of rectum was compared to the means of ICRU rectal point and rectal $D_{Max}$ using the Student's t-test. The mean $D_{2cc}$ of bladder was compared with the mean ICRU bladder point using the same statistical test. The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (${\alpha}/{\beta}$ value of 10 Gy for target, 3 Gy for organs at risk). Results: The total prescribed dose was $77.5Gy{\alpha}/{\beta}10$. The mean dose to the rectum was $4.58{\pm}1.22Gy$ for $D_{2cc}$, $3.76{\pm}0.65Gy$ at $D_{ICRU}$ and $4.75{\pm}1.01Gy$ at $D_{Max}$. The mean rectal $D_{2cc}$ dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48-1.19Gy). The mean EQD2 was $68.52{\pm}7.24Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$, $61.71{\pm}2.77Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$ and $69.24{\pm}6.02Gy_{{\alpha}/{\beta}3}$ at $D_{Max}$. The mean ratio of $D_{2cc}$ rectum to $D_{ICRU}$ rectum was 1.25 and the mean ratio of $D_{2cc}$ rectum to $D_{Max}$ rectum was 0.98 for all individual fractions. The mean dose to the bladder was $6.00{\pm}1.90Gy$ for $D_{2cc}$ and $5.10{\pm}2.03Gy$ at $D_{ICRU}$. However, the mean $D_{2cc}$ dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25Gy). The mean EQD2 was $81.85{\pm}13.03Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$ and $74.11{\pm}19.39Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$. The mean ratio of $D_{2cc}$ bladder to $D_{ICRU}$ bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose. Conclusions: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the $D_{2cc}$ and rectal $D_{Max}$ for $D_{2cc}$. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the $D_{2cc}$.