• 제목/요약/키워드: Unipolar wave

검색결과 13건 처리시간 0.017초

Degradation of 0.2PMN-0.8PZT Multilayer Ceramic Actuators

  • Song, Jae-Sung;Koh, Jung-Hyuk;Jeong, Soon-Jong;Wee, Sang-Bong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권1호
    • /
    • pp.6-9
    • /
    • 2005
  • Aging characteristics of 0.2PMN-0.8PZT multilayer ceramic actuators (MCA) has been investigated by applying both triangular wave function for unpoled and unipolar wave for poling. P-E hysteresis loops of the MCA had been distorted after about 90 million cycles running in triangular wave function. Effective electromechanical coupling coefficient was calculated in resonant and anti resonant frequencies. And pseudo-piezoelectric constant $d_{33}$ was also estimated from the strain versus electric field characteristics. The crack growth of MCA was clearly observed along to the boundary between electrode and inactive area. That results were thought due to the internal tensile stress came from both actuation of $d_{33}$ mode and motion of Poisson ratio.

정상적인 한국 흑염소의 심전도에 관한 연구 II. 담부단극유도의 파형과 전위 (Studies on Electrocardiogram of the Normal Korean Native Goat II. Waveforms and Amplitudes of the Unipolar Precordial Chest Leads)

  • 최인혁;김기주;윤여백;서석열;김남수
    • 한국임상수의학회지
    • /
    • 제14권2호
    • /
    • pp.338-348
    • /
    • 1997
  • The electrocardiographic (ECG) parameters on unipolar precordial chest leads in the normal Korean native goat of 343 heads as to CV$_{6}$LU, CV$_{6}$LL CV$_{6}$RU, CV$_{6}$RL and V10 have been measured with a 3-channel Elertrocardiograph and computed, analysed. All wave types as positive, negatives biphasic and flatting in the P and T waves appeared in all leads but any special wave type was not shown more than 60%. Average amplitudes with the highest frequent rate in P wave were 81.4$\pm$32.0 $\mu $V (52.3%), 59.6$\pm $ 27.5 $\mu $V (50.5 %) of Positive type in leads CV$_{6}$LU and CV$_{6}$LL, and -5fl.5$\pm $22.6 $\mu $V (44.0%) of negative type in leads VIO, and 51.3% and 44% of flatting type in leads CV$_{6}$RU and CV$_{6}$RL, but flatting type of clinic form appeared frequent rate between 53% and 77% in all leads. In T wave, average amplitudes with the highest frequent rate were 265.0$\pm $97.1 $\mu $V (54.0%) and 212.2$\pm $90.7 $\mu $V (57.0%) of positive type in leads CV$_{6}$LL and CV$_{6}$RL, and -252.8$\pm $90.7 $\mu $V (56.6%) of negative in lead V10, but amplitudes of T waves that positive and negative type appeared similarity frequent ra蛇 ware 208.7$\pm $99.7 $\mu $V (42.1%), -159.0$\pm $81.6 (43.8%) in lead CV$_{6}$LU and 153.2$\pm $139.0 $\mu $V (47.3%), -130.0$\pm $81.4 (43.2%) in lead CV$_{6}$RU, Amplitudes of QRS complex wave forms showed the highest frequent rate were 218.2$\pm $96.4 $\mu $V (47.8%), 308.3$\pm $135.2 $\mu $V (46.8 %), 232.8$\pm $126.5 $\mu $V (58.5%) and 225.3$\pm $89.6 $\mu $V (54.9%) of R type in the leeds CV$_{6}$LU, CV$_{6}$LL, CV$_{6}$RU and CV$_{6}$RL, and were -92.5$\pm $79.1 $\mu $V,479.0 $\pm $116.6 $\mu $V (33.2%) and 212.1 $\pm $86.7 $\mu $V (32.8%) of QR and 05 type in the lead V10. These results in the V10, CV$_{6}$RU, CV$_{6}$RL, CV$_{6}$LU, CV$_{6}$LL. may be not starve to purpose of unipolar precordial chest leads.

  • PDF

반응성 스퍼터링법으로 형성시킨 PZT 커패시티의 P-E 이력곡선의 이동현상 및 피로 특성 연구 (Study on the Shift in the P-E Hysteresis Curve and the Fatigue Behavior of the PZT Capacitors Fabricated by Reactive Sputtering)

  • 김현호;이원종
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.983-989
    • /
    • 2005
  • [ $PZT(Pb(Zr,Ti)O_3)$ ] thin films were deposited by multi-target reactive sputtering method on $RuO_2$ substrates. Pure perovskite phase PZT films could be obtained by introducing Ti-oxide seed layer on the $RuO_2$ substrates prior to PZT film deposition. The PZT films deposited on the $RuO_2$ substrates showed highly voltage-shifted hysteresis loop compared with the films deposited on the Pt substrates. The surface of $RuO_2$ substrate was found to be reduced to metallic Ru in vacuum at elevated temperature, which caused the formation of oxygen vacancies at the initial stage of PZT film deposition and gave rise to the voltage shift in the P-E hysteresis loop of the PZT capacitor. The fatigue characteristics of the PZT capacitors under unipolar wane electric field were different from those under bipolar wane. The fatigue test under unipolar wane showed the increase of polarization. It was thought that the ferroelectric domains which had been pinned by charged defects such as oxygen vacancies and the charged defects were reduced in number by combining with the electrons injected from the electrode under unipolar wave, resulting in the relaxation of the ferroelectric domains and the increase of polarization.

Radio-over-Fiber 시스템을 위한 40 GHz 대역에서 직접 광스위칭 CDMA 연구 (Study on direct optical switching CDM at 40 GHz-band for Radio-over-Fiber(RoF) system)

  • 최재원;전영민;변영태;우덕하;박종대;서동선
    • 한국광학회지
    • /
    • 제14권6호
    • /
    • pp.600-605
    • /
    • 2003
  • Radio-over-Fiber(RoF) 시스템에서 직접 광스위칭 CDMA(Direct Optical Switching CDMA : DOS-CDMA) 기법을 이용하여 기존 이동통신에서 연구되어왔던 수 ㎓ 대역보다 주파수가 훨씬 높은 40 ㎓ 대역의 MMW (millimeter wave)를 반송파로 사용한 차세대 이동통신을 위한 MMW DOS-CDMA 시스템 연구를 실험적으로 수행했다. 부호 분할 다중화에 사용된 직교 부호(orthogonal codes)는 단극성(unipolar) 형태의 상호상관이 2이하(crosscorrelation$\leq$2)인 부호열을 선택했으며, 부호 길이(code length)는 16 chips, 칩율(chip rate)은 2.5 Gchip/sec 였다. 광원은 10 ㎓ 광섬유 링 레이저를 유리고조모드 잠김시켜 진폭 균등화한 40 ㎓ 의 안정된 레이저 펄스를 발생시켜 사용하였다.

Modified Unipolar Carrier-Based PWM Strategy for Three-Level Neutral-Point-Clamped Voltage Source Inverters

  • Srirattanawichaikul, Watcharin;Premrudeepreechacharn, Suttichai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.489-500
    • /
    • 2014
  • This paper presents a simple modified unipolar carrier-based pulsewidth modulation (CB-PWM) strategy for the three-level neutral-point-clamped (NPC) voltage source inverter (VSI). Analytical expressions for the relationship between modulation reference signals and output voltages are derived. The proposed modulation technique for the three-level NPC VSI includes the maximum and minimum of the three-phase sinusoidal reference voltages with zero-sequence voltage injection concept. The proposed modified CB-PWM strategy incorporates a novel method that requires only of one triangular carrier wave for generate the gating pulses in three-level NPC VSI. It has the advantages of being simplifying the algorithm with no need of complex two/multi-carrier pulsewidth modulation or space vector modulation (SVM) and it's also simple to implement. The possibility of the proposed CB-PWM technique has been verified though computer simulation and experimental results.

정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位) (Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads)

  • 최인혁;김수용;김남수;서두석
    • 대한수의학회지
    • /
    • 제33권4호
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Treatment of Bone Repair by Inductively Magnetic Fields

  • 안재목;;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.213-217
    • /
    • 1992
  • An inductively coupled magnetical signal (pulse wave, 0.7 to 60Hz, eighteen volts peak to Peak) that was applied non-invasively on the skin surface overlying the approximate site(measure position). In the group with unipolar pulse signal currents produced smaller than in the group with bipolar pulse signal. The signal was transmitted to the active coil, including a time-varying magnetic field: this in turn induced a the-varying electrical field in the field in the bone. It is very important to determine system parameters due to treatment time(healing) and the simplicity. This paper investigation was designed to compare the relative effects of pulsed unipolar currents with the effects of an identical pulsed bipolar currents. Since Inductive coupling is non-invasive and involves portable equipment, it is easy to apply and requires precise localization, it has distinct advantages and field characteristics along the bone for each different signal.

  • PDF

내혈관 침자극이 심전도 단그지유도변화에 미치는 영향 (Effects of Naegwan-Acupuncture on the Change of Augmented Unipolar limb leads aVR, aVL and aVF in ECG)

  • 김종철;김연숙;박성호;김이화;고은희;성현제;김정범
    • 동의생리병리학회지
    • /
    • 제18권2호
    • /
    • pp.522-527
    • /
    • 2004
  • The aim of this study is to investigate the effect of Naegwan-Acupuncture stimulation on the relationship of change in electrocardiopgraphy(EGG). For this purpose, 11 normal volunteers were acupunctured at Naegwan acupoint using the method of Young-Su-Bo-Sa. Then, we measured and observed the change of augmented unipolar limb leads aVR, aVL and aVF in EGG. In aVR, Naegwan acupuncture treated groups were increased the activity of PR interval and PR segment compared to the control group. In aVL, Naegwan acupuncture treated groups were increased the activity of R wave amplitude, PR interval and PR segment. In aVF, Naegwan acupuncture treated groups were increased the activity of S wave amplitude and PR interval. These results suggested that Naegwan acupuncture stimulation play an important role to the activities of EGG.

단일칩 마이컴을 이용한 위상변위 방식 풀브리지 직류-직류 전력변환기 (Phase-Shift Full-Bridge DC-DC Converter using the One-Chip Micom)

  • 정강률
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.517-527
    • /
    • 2021
  • 본 논문에서는 단일칩 마이컴을 이용한 위상변위 방식 직류-직류 전력변환기를 제안한다. 제안한 전력변환기의 1차측은 위상변위 방식에 의하여 단극성 펄스폭변조(unipolar PWM)로 동작하는 풀브리지 전력구조이며, 2차측은 4개의 다이오드로 구성된 풀브리지 전파정류기이다. 제안한 전력변환기의 제어는 단일칩 마이컴에 의해 수행되고, 그 MOSFET 스위치들은 부트스트랩 회로에 의해 구동된다. 그래서 전력변환기의 전체 시스템은 간단하다. 제안한 전력변환기는 공진회로와 저지커패시터를 이용하여 고효율을 달성한다. 본 논문에서는 먼저, 제안한 전력변환기의 전력회로의 동작을 각 동작모드를 따라 설명한다. 그리고 제안한 전력변환기의 전력회로 설계방식을 보이고 제안한 전력변환기를 동작시키는 마이컴 상의 소프트웨어 제어 알고리즘과 피드백 및 스위치 구동 회로에 관하여 간략히 설명한다. 그 후, 본 논문에서 제시한 설계와 구현방식에 의하여 설계하고 제작된 시제품 전력변환기의 실험결과를 통하여 제안한 전력변환기의 동작 특성을 입증한다. 실험결과에서 약 92% 정도의 최고 효율을 얻었다.

개구리 심전도(EKG) 및 혈액상의 계절에 따른 변화 (Changes of the Electrocardiogram and Blood Picture of Frogs in Four Seasons)

  • 이정무;배성호;신현찬;채의업
    • The Korean Journal of Physiology
    • /
    • 제8권2호
    • /
    • pp.33-44
    • /
    • 1974
  • The electrocardiogram of frogs were obtained in winter (January), spring (April), summer (July) and autumn (September and November). Electrocardiograms were recorded applying electrodes to the atria, ventricle and apex of the heart by unipolar or bipolar leads. V wave was recorded prior to P wave, for the presence of the sinus venosus which controls the automaticity of the frog heart, in four seasons. Regardless of the leads or the position of the electrodes P wave was diphasic and wide. According to the rise of temperature the rate of heart beat was increased, and V-P and P-R interval were shortened. Two regression line between R-R interval and both V-P interval and P-R interval were drawn. These were calculated as V-P interval=1 0.276R-R $interva1+0.067{\pm}0.15$ (sec.) and P-R interval=0.179R-R $interva1+0.155{\pm}0.1$ (sec). From these calculation the larger gradient of V-P interval than P-R interval was suggestive that the heart rate is more dependent on the changes of V-P interval than that of P-R interval. Changes of the heart rate were also measured in four seasons and artificial temperatures. Two regression lines between the heart rate (H.H.) and both seasonal temperature (T) and artificial temperature, were drawn. These two lines were calculated as H.R.=20+3.71 (T-10) and H.R.=32+1.425 T respectively. From two gradients of the above equations it is considered that the changes of the heart rate in artificial temperature were milder than that in seasonal temperature. The number of RBC and WBC of frogs were measured in four seasons and a tendency of the changes was observed according to the seasonal variation.

  • PDF