• Title/Summary/Keyword: Unipolar II

Search Result 6, Processing Time 0.027 seconds

The Development of Calculation Algorithm of Power Loss for Inverter in BLDC Motor Drive with Switching Modes (스위칭 방식에 따른 BLDC Motor 구동용 인버터의 전력 손실 계산 알고리즘 개발)

  • Kim, Sang-Hoon;Lee, Young-Cheol
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.119-126
    • /
    • 2004
  • BLDC Motor is one of the widely utilizable motors in servo system. The accurate calculation of the power loss for the IGBT and Inverse diode with Bipolar and Unipolar switching modes the driving modes is important for the design of drives for their heat treatment. If it were not for temperature-sensors in devices, it is difficult to get direct power loss, so. Power losses may be modeled by computer modeling to obtain the Calculation of the Power loss for Inverter in BLDC Motor with switching modes which is presented in this paper. The computer modeling is carried out by Matlab simulation. The power loss consists of conduction losses Conduction losses are the source of occurrence due to The IGBT and Inverse diode currents. Switching losses are the source of occurrence due to switching on/off in the devices, and gives the dominant influence to the loss. As a result, the unipolar I mode is best in reducing the heat losses.

  • PDF

Studies on Electrocardiogram of the Normal Korean Native Goat II. Waveforms and Amplitudes of the Unipolar Precordial Chest Leads (정상적인 한국 흑염소의 심전도에 관한 연구 II. 담부단극유도의 파형과 전위)

  • 최인혁;김기주;윤여백;서석열;김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.338-348
    • /
    • 1997
  • The electrocardiographic (ECG) parameters on unipolar precordial chest leads in the normal Korean native goat of 343 heads as to CV$_{6}$LU, CV$_{6}$LL CV$_{6}$RU, CV$_{6}$RL and V10 have been measured with a 3-channel Elertrocardiograph and computed, analysed. All wave types as positive, negatives biphasic and flatting in the P and T waves appeared in all leads but any special wave type was not shown more than 60%. Average amplitudes with the highest frequent rate in P wave were 81.4$\pm$32.0 $\mu $V (52.3%), 59.6$\pm $ 27.5 $\mu $V (50.5 %) of Positive type in leads CV$_{6}$LU and CV$_{6}$LL, and -5fl.5$\pm $22.6 $\mu $V (44.0%) of negative type in leads VIO, and 51.3% and 44% of flatting type in leads CV$_{6}$RU and CV$_{6}$RL, but flatting type of clinic form appeared frequent rate between 53% and 77% in all leads. In T wave, average amplitudes with the highest frequent rate were 265.0$\pm $97.1 $\mu $V (54.0%) and 212.2$\pm $90.7 $\mu $V (57.0%) of positive type in leads CV$_{6}$LL and CV$_{6}$RL, and -252.8$\pm $90.7 $\mu $V (56.6%) of negative in lead V10, but amplitudes of T waves that positive and negative type appeared similarity frequent ra蛇 ware 208.7$\pm $99.7 $\mu $V (42.1%), -159.0$\pm $81.6 (43.8%) in lead CV$_{6}$LU and 153.2$\pm $139.0 $\mu $V (47.3%), -130.0$\pm $81.4 (43.2%) in lead CV$_{6}$RU, Amplitudes of QRS complex wave forms showed the highest frequent rate were 218.2$\pm $96.4 $\mu $V (47.8%), 308.3$\pm $135.2 $\mu $V (46.8 %), 232.8$\pm $126.5 $\mu $V (58.5%) and 225.3$\pm $89.6 $\mu $V (54.9%) of R type in the leeds CV$_{6}$LU, CV$_{6}$LL, CV$_{6}$RU and CV$_{6}$RL, and were -92.5$\pm $79.1 $\mu $V,479.0 $\pm $116.6 $\mu $V (33.2%) and 212.1 $\pm $86.7 $\mu $V (32.8%) of QR and 05 type in the lead V10. These results in the V10, CV$_{6}$RU, CV$_{6}$RL, CV$_{6}$LU, CV$_{6}$LL. may be not starve to purpose of unipolar precordial chest leads.

  • PDF

High Accuracy and Stability Unipolar Magnet Power Supply by Phase-Shifted Parallel Operation of the Buck-Converter (벅-컨버터의 위상천이 병렬운전 방식을 적용한 고정밀, 고안정 단방향 전자석전원장치)

  • Kim, Sung-Chul;Moon, Cheol;Sung, Chi-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1012-1013
    • /
    • 2015
  • 포항가속기 연구소 PLS-II 저장링은 빔에너지 3.0 GeV, 빔전류 400 mA 그리고 5.8 mm-rad로 성능을 향상 하였다. 저장링 전체의 이극, 사극, 육극 및 셉텀 전자석의 구동을 위하여 디지털 제어기를 적용한 독립된 강압형 buck-converter를 인터리버 방식으로 응용한 고정밀 단방향 전자석전원장치를 개발 하였다. 이들 전자석전원장치의 출력전류 안정도는 +/-10 ppm 이하이다. 본 논문에서는 PLS-II 저장링의 단방향 전자석전원장치의의 설계 및 성능에 대하여 논하고자 한다.

  • PDF

Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位))

  • Choi, In-hyuk;Kim, Soo-young;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Studies on- Electrocardiogram of the Normal Korean Native Goat 1. Standard Limb Leads and Unipolar Limb Leads (정상적인 한국 흑염소의 심전도에 관한 연구 1. 표전지유도와 단극지유도)

  • 최인혁;김선기;김추철;최인방;김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.319-337
    • /
    • 1997
  • The electrocardiographic (ECG) parameters in the normal Korean black goat have been measured with a 3-channel Electrocardiograph and computed, analyzed. ECG in 243 black goats were made with the limb leads (I, II, III, aVR, aVL, aVF), that were recorded conduction parameters of wave and interval, and were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate were recorded by the ECG which were a mean of 106.1$\pm $21.8 beats/min. Average conduction times in the PR, the QRS complex and the QTc interval were recorded 103.9$\pm $34.9 msec., 58.3$\pm $23.2 msec. and 302.6$\pm $67.8 msec., in the P and T wave duration recorded 24.8$\pm $6.4 msec. and 51.7$\pm $10.8 msec. respectively. The shape of wave in each leads were observed various types, and any spacial wave type appeared the highest frequency in each lead that ware shown less than 60%, and these frequent rate and average amplitudes as fallow: 1. In P waver the frequent rate and average amplitudes of the positive type showed in leads I, II and aVL that were 54.8% (93.0$\pm $ 33.2 $\mu $V), 50.5% (90.1$\pm $30.5 $\mu $V) and 41.7% (58.5$\pm $ 31.1 $\mu $V). Average amplitude of the negative type showed the frequent rate of 49.8% in lead aVE which was -77.6$\pm$ 25.2 $\mu $V. Biphasic type in leads III and aVF were 46.1% (108.4 $\mu $V, -90.2 $\mu $V.) and 45.7% (137.4 $\mu $V, -105.4 $\mu $V.), and amplitudes between positive and negative of it were significant difference. 2. The highest amplitudes of the QRS complex in all leads were 534.8$\pm $ 232.3 $\mu $V of lead II. The frequent rate and amplitudes of the R wave type in the I, II, III and aVF were 30.2% (277.8 $\pm $131.3 $\mu $V), 45.1% (393.1$\pm $114.2 $\mu $V), 48.5% (349.3$\pm $178.3 $\mu $V) and 54.9% (334.4$\pm $129.7 $\mu $V), and QS ways type in the lead aVL was 49.5% (359.2$\pm $195.5$\mu $V), and RS and QS wave types in the lead a VR were 43.3% (312.4 $\mu $V, -212.7 $\mu $V.) and 41.1% (399.2$\pm $92.2 $\mu $V), respectively. 3. In T wave, the frequent rata and amplitudes of the positive type in the leads I, II, III and aVF were 44.6% (207.9$\pm $ 97.1 $\mu $V), 41.6% (245.1$\pm $92.1 $\mu $V), 46.9% (189.8$\pm $ 82.7 $\mu $V) and 53.0% (195.4197.8 $\mu $V), and the negative in the lead aVR was 41.2% (-230.7$\pm$ 103.1 $\mu $V), respectively. The positive and negative types in the lead aVe appeared with same frequent rate of 43.2%.4. Frontal plane vectors for P, QRS, and T were found to lie at 38.1$\pm $ 21.5, 142.0$\pm $ 57.2, and 117.2$\pm $ 63.9 degrees, respectively. These results in ECG of goats may be served to the limited purposes as to conduction parameters, arrhythmias except abnormal ECG because of waveforms, amplitudes and electrical axis of it were variability.

  • PDF

Studies on the Electrocadiogram in Non-human Primates Reared in Korea (國內 飼育 원숭이의 心電圖에 관한 硏究)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.