Design of Narrowband Voltage Controller for Large Capacity Uninterruptible Power Supply with Low Switching Frequency (낮은 스위칭 주파수를 갖는 대용량 무정전전원장치를 위한 협대역 전압제어기 설계)

  • Yoon, Chun-gi;Cho, Younghoon;Lim, Seung-beom
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.149-150
    • /
    • 2015
  • This paper presents narrowband voltage controller for large capacity UPS system with low switching frequency. The proposed controller is repetitive controller applicable to low sampling. The controller reduces the control error for nonlinear load and improve efficiency. The proposed controller is verified through the experiment using 40kW UPS inverter.

  • PDF

Design of Odd Harmonic Repetitive Controller for Uninterruptible Power Supply (무정전 전원장치를 위한 홀수고조파 반복제어기의 설계)

  • Yoon, Chun-gi;Cho, Younghoon;Lim, Seung-beom
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.147-148
    • /
    • 2015
  • This paper presents an odd harmonic repetitive controller for single-phase UPS inverters. The proposed repetitive controller achieves the low output voltage THD and reduces the steady-state error by eliminating odd harmonic distortions caused by nonlinear and unbalanced loads. The proposed control scheme is verified through experiment using a 5kW single-phase T-type inverter.

  • PDF

Highly Power-Efficient Rack-Level DC Power Architecture Combined with Node-Level DC UPS

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • v.33 no.4
    • /
    • pp.648-651
    • /
    • 2011
  • This letter presents a highly efficient rack-level DC power architecture combined with a node-level DC uninterruptible power supply (UPS). The proposed system can provide almost the equivalent power efficiency of a high-voltage DC data center without any change in the existing power infrastructure. The node-level DC UPS combined with a power distribution board provides high power efficiency as well as lower UPS installation costs. Implemented on a rack, the entire power system can be monitored through a network.

A Study on the Distortion Reducing of Output Voltage for UPS by Estimated Load Current (부하전류 예측에 의한 UPS의 출력전압 왜형률 개선에 관한 연구)

  • 변영복;박성준;추영배;권순재;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • The uninterruptible power supply (UPS) has become an integral part of modern computer and communication system to assure a continued and stable operation by providing an uninterruptible power to vital equipments. Various control methods have come to the fore in recent times with the advent of high frequency switching technologies. This paper describes the DSP control method for three phase UPS inverter which guarantees the sinusoidal output voltage under nonlinear load conditions. The proposed control scheme is verified by simulation and experiment.riment.

  • PDF

Model Predictive Control of Three-Phase Inverter for Uninterruptible Power Supply Applications under a Hexagonal Input Constraint Region (육각형 입력제약 공간을 이용한 무정전 전원장치의 모델예측제어)

  • Kim, Seok-Kyoon;Kim, Jung-Su;Lee, Young Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Using the classical cascade voltage control strategy, this paper proposes an analytical solution to an MPC (Model Predictive Control) problem with a hexagonal input constraint set for the inner-loop to regulate the output voltage of the UPS (Uninterruptible Power Supply). Focus is placed on how to deal with the hexagonal input constraint set without any approximation. Following the conventional cascade voltage control strategy, the PI (Proportional-Integral) controller is used in the outer-loop in order to regulate the output voltage. The simulation results illustrate that the capacitor voltage rapidly goes to its reference in a satisfactory manner while keeping other state variables bounded under an unexpected load changes.

The Development of Remote Monitoring & Control System using Modem Uninterruptible Power Supply (모뎀을 이용한 무정전 전원장치(UPS) 원격감시제어시스템 개발)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.445-447
    • /
    • 1997
  • In this paper a remote monitoring and control system using Modem for UPS (Uninterruptible Power Supply) is proposed. The conventional remote monitoring system for UPS is used to local remote monitoring system by RS232 or RS485 communication code. But recently. the system is changed to wide remote monitoring and control system using Modem for quick analysis of errors, correction of errors, report of errors and other user-friendly functions. In this study, we designed and develope system which is able to control UPS an monitor errors, statuses, actual values transmitted from UPSs of each site.

  • PDF

New 3-Phase Phase Locked Loop(PLL) Strategy Haying Frequency Limiter and Anti-windup Suitable to Uninterruptible Power Supply (무정전전원장치에 적합한 주파수 제한기와 안티 와인드업을 가지는 새로운 3상 전원각 정보 추출 방식)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1086-1091
    • /
    • 2006
  • In this paper an advanced PLL strategy suitable to UPS, compared with conventional PLL strategy using the positive sequence component extracted from source voltages, is suggested. Frequency limiter and anti-windup are added to conventional PI controller in suggested PLL strategy. Basic operational principle of suggested PLL is same as that of conventional PLL, but the difference between two strategies is that the suggested PLL can limit the change of frequency in constant range because of inclusion of frequency limiter. Compute. simulation was carried fer the DVR(dynamic voltage restorer) compensating voltage to examine the difference between conventional PLL strategy and the suggested PLL strategy limiting frequency. And the results clearly demonstrate the effectiveness of the suggested PLL strategy for UPS.

  • PDF

Investigation of Dynamic Characteristcs Uninterruptible Power Supply System (UPS) Using Shaking Table Tests (무정전전원장치(UPS)의 진동대 실험 및 동적특성 분석)

  • Lee, Seung-Jae;Kim, Joo-Young;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.129-136
    • /
    • 2019
  • Non-structural elements are vulnerable to earthquake ground motion. In this study, an experimental study for the electrical non-structural element was performed using tri-axial shaking table tests. A 100kVA UPS(Uninterruptible Power Supply system) was used as the test specimen. The test specimen was anchored to the concrete slab using the conventional installation detail. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration with respect to the required response spectrum defined in ICC-ES AC156 were from 25% to 600%. Based on the test results, damage and dynamic characteristics of UPS were evaluated and analyzed including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement.

No-Break Power Transfer System to Minimize the Cross-Over Current for Low-priced Uninterruptible Power Supply (순환전류 발생을 최소화하는 저가형 UPS용 무순단 출력 절환시스템)

  • Joung, Seok-Eon;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.357-359
    • /
    • 2008
  • 소 용량 혹은 저가형 UPS의 동기 방법 및 고장 시 절환 방법을 나열하고 그 장단점을 설명한다. 제안의 요지는 가장 간단한 동기 판별기능이 없는 동기화 회로를 사용하는 저가형 UPS에서 발생 될 수 있는 순환전류를 시뮬레이션 하고 이를 바탕으로 최적의 효과를 갖는 절환 시스템을 제안 하고 시뮬레이션을 통해 문제점과 타당성을 입증 한다.

  • PDF

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Serise Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.201-203
    • /
    • 2005
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently, In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state.