• 제목/요약/키워드: Uninterruptible

검색결과 221건 처리시간 0.024초

Sag와 Swell에 따른 계통 이상 검출에 관한 연구 (The Study of Grid Fault Detection for Sag, Swell)

  • 김민기;노용수;김준구;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

직.병렬 인버터를 이용한 동적전압보상기 (Dynamic Voltage Compensator using Series and Shunt Inverters)

  • 박덕희;이준기;한병문;소용철;김현우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권11호
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

전력저장전지시스템의 경제성 평가 (Economic Evaluations of Secondary Battery Energy Storage Systems in Power Distribution Systems)

  • 노대석;오용택
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.152-160
    • /
    • 2000
  • This paper presents an efficient evaluation method on the role of new energy storage systems, especially the secondary Battery Energy Storage (BES) systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a synthetical and quantitative manner, because they are very costly in the early stage of their development and commercialization. In this paper, the multiple functions of BES systems, which are operated at distribution systems, such as load levelling, effective utilization of power distribution systems and uninterruptible power supply at the emergency conditions are classified and analyzed. And then the quantitative evaluation methods of the multiple functions for BES systems are proposed using the mathematical modelling.

  • PDF

0.7 MJ UPS용 초전도 케이블의 ?치 특성 (Quench Characteristics of the Superconduction Cable for a 0.7 MJ UPS)

  • 류경우;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제11권7호
    • /
    • pp.565-570
    • /
    • 1998
  • Recently a few MJ superconducting magnetic energy storage ($\mu$ SMES) devices become commerci-ally available as one of the energy storage devices for uniterruptible power supply (UPS) systems. For such a ($\mu$ SMES) devics, a few kA class superconducting cables with high current density, high stability and excellent pulse characteristics are required. To acquire data for the superconduction cables related to design and fabrication of a 0.7 MJ $\mu$ SMES device, we tested critical currents and quench characteristics for several winding tensions and various remping rates especially. It is shown from the results that winding tensions have much influence on quench currents of the $\mu$ SMES devices.

  • PDF

발전소 직류전압 전선로 접지검출시스템에 관한 연구 (A Study on Ground Fault Detecting System for DC Voltage Line in the Electric Power Plant)

  • 이형기;김남호;박찬호;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.754-757
    • /
    • 1995
  • This system can detect a ground fault point or a bad insulated line by measuring a power plant DC feeder insulation resistance at the uninterruptible power status. And when the power plant DC feeder with low frequency AC signal has a ground fault, this measuring system can keep recording of its ground fault current and phase checked by Z.C.T. Therefore the power plant could protect a unexpected service interruption.

  • PDF

Highly Power-Efficient Rack-Level DC Power Architecture Combined with Node-Level DC UPS

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • 제33권4호
    • /
    • pp.648-651
    • /
    • 2011
  • This letter presents a highly efficient rack-level DC power architecture combined with a node-level DC uninterruptible power supply (UPS). The proposed system can provide almost the equivalent power efficiency of a high-voltage DC data center without any change in the existing power infrastructure. The node-level DC UPS combined with a power distribution board provides high power efficiency as well as lower UPS installation costs. Implemented on a rack, the entire power system can be monitored through a network.

UPS를 내장한 컴퓨터용 SMPS (The SMPS with a Bulit-in UPS for Computer)

  • 이성룡;전칠환;이수원;고성훈;권혁대
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권8호
    • /
    • pp.495-499
    • /
    • 2004
  • UPS(Uninterruptible Power Supply) have been used to improve power source quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because batteries. So, a UPS size issue has received the attention in the power electronics industry. This paper proposed an implementation of the computer power supply with a bulit-in UPS controlled by the one-chip microprocessor to minimize UPS size. The experimental results verified the proposed SMPS with a bulit-in UPS for computer.

리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험 (The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System)

  • 이학주;채우규;박중성;손진만;최은식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

독립형 태양광 발전 시스템의 무정전 전력공급을 위한 시스템 용량 최적 선정에 관한 연구 (A Research on the Optimal System Sizing of the Standalone Photovoltaic Power Generation System for Uninterruptible Power Supply)

  • 김기영;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.68-69
    • /
    • 2017
  • 본 논문에서는 독립형 태양광 시스템의 설계에서 배터리 용량 선정 방식에 관련하여 부하손실확률(LLP: Loss of Load Probability)이 0 인 기준을 토대로 시스템 무정전 전력공급을 위한 시행 착오법을 제안하였으며 시스템의 수명주기비용(LCC: Life Cycle Cost)을 분석하여 기존 시스템에 비해 경제성을 높이고자 한다. 제안한 방식의 검증을 위하여 시뮬레이션을 수행하였다.

  • PDF

1,200kVA급 모듈형 하이브리드 무정전전원장치 개발 (The development of 1,200kVA Modular Hybrid UPS)

  • 변용섭;임승범;김지수;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.423-424
    • /
    • 2017
  • 본 논문은 에너지저장(ESS : Energy Storage System) 기능을 갖는 1,200kVA급 모듈형 하이브리드 무정전전원장치(UPS : Uninterruptible Power Supply)에 관한 것이다. 제안한 모듈형 하이브리드 UPS는 평상시에는 무정전전원장치의 기능을 수행하면서 잉여 전력을 미리 배터리에 저장하였다가 첨두부하시 또는 전력 부족시 에너지저장 기능을 하여 전력을 조절할 수 있다.

  • PDF