PWM Inverter Controller Design for UPS(Uninterruptible Power Supply) Using a DSP(TMS320F240) (DSP(TMS320F240)을 이용한 무정전 전원장치(UPS)용 PWM 인버터 제어기 설계)

  • Jang, J.Y.;Lee, J.P.;Choi, J.Y.;Choy, I.;Lee, S.C.;Yoo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2587-2589
    • /
    • 1999
  • In this paper, we propose a new control scheme for a PWM inverter using digital control. Digital control has various advantages in comparison with conventional analogue control. It can achieve high frequency switching of inverter and can be little influenced for temperature variations and aging of devices. This digitally-controlled PWM inverter is implemented using a Digital Signal Processor(DSPTMS320F240). The simulation results are given to verify the DSP based PWM inverter design and implementation.

  • PDF

Development of UPS Using MICOM and GUI (마이컴과 GUI에 의한 무정전 전원장치의 개발)

  • Kim, D.W.;Hwang, G.H.;Shin, D.L.;Park, S.W.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.21-23
    • /
    • 2003
  • 본 논문에서는 전원선로의 정전시나 입력전원에 이상 상태가 발생했을 때 정상적인 전원을 부하에 공급하는 마이컴과 GUI를 이용한 무정전 전원장치(Uninterruptible Power System : UPS)를 개발하였다. 본 논문에서 개발한 무정전 전원장치는 PIC16F877의 마이컴을 사용하였으며, 사용자가 편리하도록 하기 위해서 Visual C++를 이용하여 무정전 전원장치의 그래픽 사용자 인터페이스를 구현하였다.

  • PDF

Active Power Filter Type Single Phase Uninterruptible Power Supply(UPS) System (단상 전력용 능동필터형 무정전 전원장치)

  • Kim, Je-Hong;Son, Jae-Hyun
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.53-59
    • /
    • 1999
  • In this paper, a bi-directional UPS with the performance of active power filter has been proposed. The operation of the proposed system can be divided into two modes, such as the active power filter mode and the battery back-up power mode. To improve the transient response for the effective compensation of harmonics and reactive power in active power filter mode, a novel closed-loop control strategy is used to calculate the reference current instantaneously. Finally, the performance of proposed UPS is verified by the simulation and experimental results.

  • PDF

고효율 무정전전원장치

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.291
    • /
    • pp.72-75
    • /
    • 2001
  • 정보네트워크산업이 급속히 발전, 보급되는 가운데 그 전원인 무정전전원장치(Uninterruptible Power Supply: UPS)에 대해서도 여러 가지 요구가 나오고 있다. 특히 최근에는 고신뢰성화$\cdot$소형화$\codt$저가격화에 더하여 러닝코스트 저감과 지구온난화 방지를 연결한 개념의 성에너지화를 목적으로 하는 전력변환효율의 향상에 대한 요구가 강해지고 있다. 이번에 이러한 요구에 응하기 위하여 미쓰비시전기는 상시상용 급전방식을 채용하여 HSS(High Speed Switch)회로와 쌍방향 컨버터회로를 개발하여, 고효율이며 급전신뢰성이 높은 MPC(Multiple Power Compensator)방식의 UPS를 개발하였다. 이에 의하여 전력변환효율을 90$\%$에서 98$\%(100kVA에서)로 대폭 개선함과 동시에 종래의 상용급전방식 UPS의 결점이었던 상용전원 이상시의 급전계통 전환시간을 부하기기에 영향을 미치지 않는 2밀리초까지 단축시켜 전환시에도 순간 단전됨이 없이 부하급전을 계속할 수 있도록 하였다. 또한 통상의 급전시에는 쌍방향 컨버터에 입력전류가 고조파보상기능을 갖게 하여 입력역률 0.99를 달성하였다.

  • PDF

Single-Phase PCS with UPS Function Based on Dc Bus Oriented Control (dc bus 중심 제어를 이용한 UPS 기능을 갖는 단상 태양광 발전 시스템)

  • Kim, Eung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.293-296
    • /
    • 2007
  • 본 논문에서는 UPS 기능을 갖는 단상 태양광 발전 시스템을 제안하였다. 제안하는 시스템은 태양광 어레이 (photovoltaic array)에서 최대전력을 얻기 위해 MPPT (maximum power point tracking)를 수행하는 컨버터, 계통전원 상태나 태양광 발전량에 상관없이 부하에 정현파 전압을 공급하는 인버터, 태양광 어레이에서 발전된 잉여전력을 계통으로 전달하거나 부하에 필요한 전력을 dc bus로 공급하는 인버터, 정전시 dc bus에 전력을 공급하는 양방향 컨버터 (bidirectional converter)로 구성된다. 제안하는 시스템은 발전된 전력을 계통으로 전달할 뿐만 아니라, UPS (uninterruptible power supply)기능도 수행하는 시스템으로 계통전압이 불안정하거나 정전시에도 부하에 안정적이고 깨끗한 전압을 항상 공급할 수 있다. 각각의 인버터, 컨버터, 및 양방향 컨버터는 dc bus를 공유하며, dc bus의 전압에 따라 동작상태가 결정이 된다. dc bus중심의 제어는 dc bus전압을 안정적으로 유지시키며, 부하에 걸리는 전압의 변동을 최소로 하고 시스템의 디자인 및 제어를 단순화한다. 모든 알고리즘과 제어기를 하나의 마이크로 컨트롤러로 구현하였고 제안된 시스템의 우수성을 실험을 통해 검증하였다.

  • PDF

Driving Algorithm on Three Phase BLDC Motor Applied 4-Switch using Voltage Doubler (Voltage Doubler를 이용한 4-스위치 3상 BLDC 전동기 구동 알고리즘)

  • Yoon, Yong-Ho;Lee, Jung-Suk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.48-52
    • /
    • 2011
  • Over the years, traditionally, six-switch three-phase inverters have been widely utilized for variable speed alternating current motor drives. Recently, some efforts have been made on the application of four-switch three phase inverter for uninterruptible power supply and variable speed drives. This is due to some advantages of the four-switch three phase inverter over the conventional six-switch three-phase inverters such as reduced price due to reduction in number of switches, reduced switching losses, reduced number of interface circuits to supply logic signals for the switches, simpler control algorithms to generate logic signals, less chances of destroying the switches due to lesser interaction among switches, and less real-time computational burden. However such as slow di/dt and speed limitation, are the inherent characteristics and main drawbacks of the four-switch configuration. Those problems can be overcome in conjugation with Voltage-doublers which has additional advantage, such as unity power factor correction.

New Bidirectional ZVS PWM Sepic/Zeta DC-DC Converter (새로운 양방향 ZVS PWM Sepic/Zeta DC-DC 컨버터)

  • Kim, In-Dong;Paeng, Seong-Hwan;Park, Sung-Dae;Nho, Eui-Cheol;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.301-310
    • /
    • 2007
  • Bidirectional DC-DC converters allow transfer of power between two dc sources, in either direction. Due to their ability to reverse the direction of flow of power, Dey are being increasingly used in many applications such as battery charge/dischargers, do uninterruptible power supplies, electrical vehicle motor drives, aerospace power systems, telecom power supplies, etc. This Paper Proposes a new bidirectional Sepic/Zeta converter. It has low switching loss and low conduction loss due to auxiliary communicated circuit and synchronous rectifier operation, respectively Because of positive and buck/boost-like DC voltage transfer function(M=D/1-D), the proposed converter is very desirable for use in distributed power system. The proposed converter also has both transformer-less version and transformer one.

The Construction-Case of Intelligent Power Management System (지능형 전력관리시스템의 구축사례)

  • 고강훈;김천식;김수용;박정우;고희석;이현우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.214-218
    • /
    • 2000
  • This paper is a study if control system with KEN that is not only superior-manufacture ability-hardware; that is to say, the hardware is HMI/SACD solution and it has been developed to sub-station and power management system, which is easy, fast and suitable for users to work with, but also compatible solution with domestic environment Futhermore, the hardware has been developed by completely domestic technology with knowledge from various actual experiences. In the long run, for uninterruptible power supply to train, building, and factory, real time tele-supervisory control to power facilities.

  • PDF

Software design of three phase uninterruptible power supply(UPS) using the realtime operating system DSP/BIOS (실시간 운영체제 DSP/BIOS를 이용한 3상 무정전전원공급장치(UPS) 소프트웨어 설계)

  • Oh Seong-Jin;Kim Kyung-Hwan;Lee Dong-Keun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.465-466
    • /
    • 2006
  • 대부분의 전력전자 시스템과 마찬가지로 3상 UPS 시스템 역시 전력전자 알고리즘 개발자가 응용프로그램을 작성할 때 하드웨어를 조작하고 초기화하는 하위 수준 코드를 작성해 왔다. 이와 같은 응용 소프트웨어와 하드웨어의 밀접한 통합은 시스템 성능차원에서는 부족함이 없으나 이식성과 유지보수 측면에서 많은 문제점을 보여왔다. 또한, 다양화 된 고객요구에 의하여 시스템이 점점 더 복잡해짐에 따라서 기존 소프트웨어 구성은 한계를 이르렀다. 본 논문에서는 TI사의 실시간 운영체제인 DSP/BIOS를 이용하여 3상 UPS 시스템 하드웨어와 응용프로그램을 분리하는 추상화 작업을 통해서 이루어진 성과에 관하여 제시한다. 분업화되고 상호 연동하는 방식의 개발 패러다임의 변화는 전력전자 알고리즘 개발자가 더 많은 시간을 알고리즘 개발에 투입 할 수 있게 하였고 다른 분야 개발자가 병렬로 소프트웨어 개발을 진행함에 따라서 전체적으로 개발기간의 단축을 가져왔다.

  • PDF

Automated Test System for UPS using LabVIEW (LabVIEW를 이용한 UPS 테스트 자동화 시스템)

  • Na Jung-Hoon;Oh Sung-Jin;Kim Kyung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.467-469
    • /
    • 2006
  • 최신의 디지털 방식 UPS(Uninterruptible Power Supply)는 10여 년 전의 아날로그 UPS에 비해 많은 설계 요인들로 인해 복잡해지고 있다. 고속-고성능의 DSP(Digital Signal Process), 다수의 I/O를 위한 FPGA(Field-Programmable Gate Array), 다기능의 사용자 인터페이스 그리고 다양한 통신 등이 그 예라고 할 수 있다. 임베디드 디자인이 이렇게 복잡해지면서 하드웨어나 소프트웨어를 신뢰성 있게 테스트하기에 기존 방법으로는 충분치 않게 되었다. 본문에서는 NI(National Instruments)의 버추얼 인스트루먼트(Virtual Instrument) 기술을 이용하여 자동화된 테스트 시스템에 대해 기술한다.