• Title/Summary/Keyword: Uninterruptible

Search Result 222, Processing Time 0.022 seconds

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Circuit (펄스다중화 보조회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Jon Young-Soo;Baek Seung-Taek;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.238-244
    • /
    • 2005
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter, The operational feasibility of proposed system was verified by computer simulations with PSCAD/EMTDC software and experimental works with 2kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel cell power system.

Three-phase Power Equalizing System with UPS Function based on Battery Storage (UPS 기능을 가지는 배터리 기반의 삼상 전력 평준화 시스템)

  • Kwon, Jung-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.353-358
    • /
    • 2012
  • In this paper, three-phase power equalizing system (PES) with UPS function is proposed. This system is based on NiMH battery with battery management system. The power conversion circuit is composed with the three-phase converter/inverter, the bi-directional converter, and the thyristor switches. The three-phase converter/inverter provides the power to the grid or get the power from the grid. Also, it operates as a UPS. The bi-directional converter charges or discharges the battery. The thyristor switches are used for connecting/disconnecting with the grid and the load. A 15 kW prototype is implemented for the verifying the performance of the proposed system.

Parallel Processing Uninterruptible Power Supply(UPS) Using Flywheel Energy Storage Unit (프라이휠 에너지 저장장치를 이용한 병열처리형 무정전 전원장치)

  • Lee, Kyu-Jong;Kim, Byung-Kweon;Lee, Heung-Ho;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1052-1054
    • /
    • 1992
  • The conventional serial UPS using battery energy storage unit is almost universally used. Despite its common usage, the conventional UPS has a number of disadvantages which may be effectively overcome by the application of flywheel energy storage unit. This paper proposes a new type of parallel processing UPS using flywheel energy storage unit, which has the feature of high power, long life, and high efficiency.

  • PDF

A Test Verified Model Development Study for Seismic Qualification(Safety) (내진검증(안전)을 위한 실험적 고찰을 이용한 해석 모델 개발연구)

  • Uk-Hwan Sur
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.286-291
    • /
    • 1998
  • This paper includes discussion on developing the test verified finite element model for one of the seismic qualification(safety) approaches. It presents a test verified finite element model of a UPS(Uninterruptible Power Supply System) to be used at KMRR, KAERI. The test verified model predicts natural frequencies within 5 percent error for all major modes below 50Hz. This model accurately represents the dynamic characteristics of the actual hardware and is qualified for its use in the final stress analysis for seismic verification.

  • PDF

The Configurations of the UPS system for large scale computer system (대용량 컴퓨터 시스템을 위한 무정전 전원공급 시스템의 구성방안)

  • Sung, Jin-Woo;Lee, Young-Joo;Kim, Sung-Jun;Son, Sang-Ho;Park, Chan-Yeol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.280-285
    • /
    • 2007
  • This study described the designed and construction of uninterruptible power supply(UPS) system for large scale computer system KISTI's supercomputer system is serviced 24 hours and power supply should be achieved in stable voltage and frequency range. We analyzed the electric power usage for 4 years, and we found several optimal parameters for new design of UPS configuration.

  • PDF

Design of Voltage Controller of DVR based on DSP (DSP를 기반으로한 DVR의 전압제어기 구현)

  • Lee won-sun;Kim soo-gon;Lim Byung-Kuk;Jeon hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.566-569
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Recently, in power system, not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer) are being studied more and more. The DVR is a series compensator which can instantaneously compensate a voltage variation in supply side, and is a more effective than a existing UPS(Uninterruptible Power Supply) which can be only used in limited range of loads such as single load. Hence, in this paper, a study of inverter side L-C filter output Voltage for DVR is discussed.

  • PDF

Internet Monitoring System for UPS using ARM Processor (ARM Processor를 이용한 UPS의 인터넷 감시)

  • Lee DongKeun;Oh SungJin;Kim KyungHwan;Kim UkDong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.870-873
    • /
    • 2004
  • 본 논문에서는 여러 산업의 전원계통에서 정전 및 순간정전 등의 사고로 발생할 수 있는 피해를 예방하는데 중요한 역할을 하고 있는 무정전전원공급장치(UPS: Uninterruptible Power Supply)의 인터넷 감시시스템에 대하여 기술한다. 별도의 네트워크 인터페이스장치를 설치할 필요가 없이 UPS를 인터넷에 직접 연결할 수 있도록 개발한 임베디드 시스템(Embedded System)의 하드웨어 구성과 다양한 네트워크 통신 프로토콜을 구현할 수 있도록 설계된 소프트웨어의 구성 및 특징을 설명하고, 인터넷에 연결된 UPS의 고장을 예방하거나 신속하게 처리할 수 있도록 개발하여 사용 중인 EMS(Ehwa Management Service)의 특징을 기술한다. 또한 EMS 서버를 이용하지 않고 간단하게 웹브라우저를 통해 감시할 수 있도록 Java 기술을 이용하여 구현한 웹감시프로그램에 대해서 기술한다.

  • PDF

Multifunctional UPS with Mode Transfer Method (모드절환식 다기능 무정전 전원장치)

  • Kim, Je-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1049-1051
    • /
    • 2001
  • This paper proposes a new control strategy of multifunctional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system performance is verified by the simulation results.

  • PDF

A PFC Controller Design for 3-Phase Modular UPS (3상 모듈형 UPS용 PFC 제어기 설계)

  • Kim, Sang-Hoon;Park, Nae-Chun
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.75-79
    • /
    • 2011
  • In this paper a new PFC Controller for 3-Phase Modular UPS(Uninterruptible Power Supplies) is proposed. The PFC circuit for 3-Phase Modular UPS is implemented using three 1-phase 3-level boost PFC circuits. To control DC output voltage, single voltage controller considering imbalance of two capacitor voltages and to regulate AC input current three independent current controllers are used in proposed PFC controller. By the proposed method, without additional hardware, THD(Total Harmonic Distortion) of input currents can be readily limited below 5% which is the harmonic current requirements by IEEE std. 519. Its validity is verified by simulations and experiments.

  • PDF

Reduction of Current Harmonic Occurred form between Uninterruptible Powers Supply and Rectifier Load (정류기 부하와 무정전전원장치 사이에 발생되는 Current Harmonic 저감)

  • 곽철훈;반한식;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.41-44
    • /
    • 1999
  • The main purpose of the UPS is to supply independent and stable power to connected equipment. In installing and operating the UPS system, songle module, three phase UPS in more benefit than multi module, songle phase UPS in the point of volume and cost. However, when supplying Rectifier with output power form three phase UPS, by connecting auto-transformer, occurred harmonic and ripple current makes output filter damaged and leads to nonlinear current coasted by unbalance load. Therefor, in this paper the aim of concentring compound-wound transformer and harmonic filter is supplying liner current by reducing harmonic and ripple current and improving unbalance in voltage and distortion in current wave.

  • PDF