• 제목/요약/키워드: Unified power quality conditioner

검색결과 40건 처리시간 0.025초

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

Precise Modeling and Adaptive Feed-Forward Decoupling of Unified Power Quality Conditioners

  • Wang, Yingpin;Obwoya, Rubangakene Thomas;Li, Zhibo;Li, Gongjie;Qu, Yi;Shi, Zeyu;Zhang, Feng;Xie, Yunxiang
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.519-528
    • /
    • 2019
  • The unified power quality conditioner (UPQC) is an effective custom power device that is used at the point of common coupling to protect loads from voltage and current-related PQ issues. Currently, most researchers have studied series unit and parallel unit models and an idealized transformer model. However, the interactions of the series and parallel converters in AC-link are difficult to analyze. This study utilizes an equivalent transformer model to accomplish an electric connection of series and parallel converters in the AC-link and to establishes a precise unified mathematical model of the UPQC. The strong coupling interactions of series and parallel units are analyzed, and they show a remarkable dependence on the excitation impedance of transformers. Afterward, a feed-forward decoupling method based on a unified model that contains the uncertainty components of the load impedance is applied. Thus, this study presents an adaptive method to estimate load impedance. Furthermore, simulation and experimental results verify the accuracy of the proposed modeling and decoupling algorithm.

다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석 (Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges)

  • 조윤호;배병열;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.241-243
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

  • PDF

A New Control Scheme for Unified Power Quality Compensator-Q with Minimum Power Injection

  • Lee, Woo-Cheol
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.72-80
    • /
    • 2007
  • Voltage sags are one of the most frequently occurring power quality problems challenging power systems today. The Unified Power Quality Conditioner (UPQC) is one of the major custom power solutions that are capable of mitigating the effect of supply voltage sags at the load or Point of Common Coupling (PCC). A UPQC-Q employs a control method in which the series compensator injects a voltage that leads the supply current by $90^{\circ}C$ so that the series compensator at steady state consumes no active power. However, the UPQC-Q has the disadvantage that its series compensator needs to be overrated. Thus it cannot offer effective compensation. This paper proposes a new control scheme for the UPQC-Q that offers minimum power injection. The proposed minimum power injection method takes into consideration the limits on the rated voltage capacity of the series compensator and its control scheme. The validity of the proposed control scheme is investigated through simulation and experimental results.

Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1015-1024
    • /
    • 2015
  • This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.

Modelling and Performance Analysis of UPQC with Digital Kalman Control Algorithm under Unbalanced Distorted Source Voltage conditions

  • Kumar, Venkateshv;Ramachandran, Rajeswari
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1830-1843
    • /
    • 2018
  • In this paper, the generation of a reference current and voltage signal based on a Kalman filter is offered for a 3-phase 4wire UPQC (Unified Power Quality Conditioner). The performance of the UPQC is improved with source voltages that are distorted due to harmonic components. Despite harmonic and frequency variations, the Kalman filter is capable enough to determine the amplitude and the phase angle of load currents and source voltages. The calculation of the first state is sufficient to identify the fundamental components of the current, voltage and angle. Therefore, the Kalman state estimator is fast and simple. A Kalman based control strategy is proposed and implemented for a UPQC in a distribution system. The performance of the proposed control strategy is assessed for all possible source conditions with varying nonlinear and linear loads. The functioning of the proposed control algorithm with a UPQC is scrutinized and validated through simulations employing MATLAB/Simulink software. Using a FPGA SPATRAN 3A DSP board, the proposed algorithm is developed and implemented. A small-scale laboratory prototype is built to verify the simulation results. The stated control scheme for the UPQC reduces the following issues, voltage sags, voltage swells, harmonic distortions (voltage and current), unbalanced supply voltage and unbalanced power factor under dynamic and steady-state operating conditions.

전기철도 급전시스템의 전기품질 향상을 위한 동기좌표계를 이용한 단상 UPQC의 제어 (A Synchronous-Reference-Frame-Based Control of Single-Phase UPQC for Improving Power Quality of AC Electrified Railway Systems)

  • 박한얼;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1951-1958
    • /
    • 2009
  • This paper presents a synchronous-rotating-frame-based control of single-phase UPQC(Unified Power Quality Conditioner) to improve power quality in ac electrified railway systems. The simulation results show that the UPQC can compensate the harmonic supply voltages, the harmonic load currents, and the reactive power in electrified railway systems. Validity of the proposed UPQC control method based on the synchronous rotating frame is illustrated through the simulation results.

  • PDF

Versatile UPQC Control System with a Modified Repetitive Controller under Nonlinear and Unbalanced Loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1093-1104
    • /
    • 2015
  • A standard repetitive controller (RC) is theoretically able to replace a bank of resonant controllers in harmonic signals tracking applications. However, the traditional RC has some drawbacks such as a poor dynamic response and a complex structure to compensate grid frequency deviations for an effective unified power quality conditioner (UPQC) control scheme. In order to solve these problems, an improved RC with an outstanding dynamic response and a simplified grid frequency adaptive scheme is proposed for UPQC control systems in this paper. The control strategy developed for the UPQC has delay time, i.e., one-sixth of a fundamental period (Tp/6), repetitive controllers. As a result, the UPQC system can provide a fast dynamic response along with good compensation performance under both nonlinear and unbalanced loads. Furthermore, to guarantee the excellent performance of the UPQC under grid frequency deviations, a grid frequency adaptive scheme was developed for the RC using a simple first order Padé's approximation. When compared with other approaches, the proposed control method is simpler in structure and requires little computing time. Moreover, the entire control strategy can be easily implemented with a low-cost DSP. The effectiveness of the proposed control method is verified through various experimental tests.

통합 전력품질 제어기의 과전류 보호방법에 관한 연구 (A Study on Over Current Protection Method of Unified Power Quality Conditioners)

  • 이우철;김한정
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.22-28
    • /
    • 2002
  • 본 논문에서는 직렬형, 병렬형 능동전력필터로 구성되어 있는 통합전력품질 제어기(UPQC)의 과전류에 대한 보호기법이 제시되며, 해석된다. 제안된 과전류 보호기법은 직렬형 능동전력필터에 과전류의 기본파 성분에 대해서고 임피던스를 갖는 기능을 부여함으로써 구현하였으며, 세 가지 방법을 제시하였다. 첫 번째 방법은 p-q이론을 이용하여 기본파 전원전류를 검출하여 보호하는 방법, 두 번째 방법은 동기 좌표계에서 부하전류의 기본파 성분을 검출하여 보호하는 방법, 세 번째 방법은 입력전압을 검출하여 보호하는 방법이다. 전원계통에서 과전류가 흘렀을 경우 제안된 방법들은 UPQC에 부가적인 회로 없이 보호해 줄 수 있다. 제안된 방법의 타당성은 시뮬레이션 결과를 통하여 입증된다.

통합 전력품질 제어기의 과전류 보호방법에 관한 연구 (A Study on Over Current Protection Method of Unified Power Quality Conditioners)

  • 채범석;이우철;이택기;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.543-547
    • /
    • 2001
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the short-circuit fault occur in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

  • PDF