• 제목/요약/키워드: Unified Control Point

검색결과 70건 처리시간 0.022초

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.

통합기준점을 이용한 KOMPSAT-3A 영상의 정밀센서모델링 가능성 분석 (Feasibility Analysis of Precise Sensor Modelling for KOMPSAT-3A Imagery Using Unified Control Points)

  • 윤완상;박형준;김태정
    • 대한원격탐사학회지
    • /
    • 제34권6_1호
    • /
    • pp.1089-1100
    • /
    • 2018
  • 본 논문에서는 국가기준점 자료를 활용한 고해상도 위성영상의 정밀센서모델 수립 가능성에 대하여 분석하였다. 이를 위해 국토지리정보원에서 운영하는 국토정보맵(http://map.ngii.go.kr/ms/map/NlipMap.do)으로부터 통합기준점 조서와 항공정사영상 자료를 이용하여 위성영상에서 통합기준점에 해당하는 영상좌표를 취득한 뒤, 이를 정밀센서모델 수립을 위한 관측자료로 활용하였다. 통합기준점 자료의 활용 가능성 분석을 위해 본 논문에서는 GNSS 측량을 통해 획득한 기준점을 활용한 정밀센서모델링 결과와 통합기준점만을 활용한 정밀센서모델링 결과를 비교하였다. 실험 결과 통합기준점만을 활용하였을 때 약 2 m의 3차원 위치결정이 가능함을 확인하였다.

Temperature control of a batch PMMA polymerization reactor using adaptive predictive control algorithm

  • Huh, Yun-Jun;Ahn, Sung-Mo;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.51-55
    • /
    • 1995
  • An adaptive unified predictive control (UPC) algorithm is applied to a batch polymerization reactor for poly(methyl methancrylate) (PMMA) and the effects of controller parameters are investigated. Computational studies are performed for a batch polymerization system model developed in this study. A transfer function in parametric form is estimated by recursive least squares (RLS) method, and the UPC algorithm is implemented to control the reactor temperature on the basis of this transfer function. The adaptive unified predictive controller shows a better performance than the PID controller for tracking set point changes, especially in the latter part of reaction course when gel effect becomes significant. Various performance can be acquired by selecting adequate values for parameters of the adaptive unified predictive controller; in other words, the optimal set of parameters exists for a given set of reaction conditions and control objective.

  • PDF

순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption)

  • 김희중;배병열;한병문;설승기;조보형
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

동작지점 투영기법을 이용한 태양광패널 모사장치의 통합 제어기법 (Unified Controller for Solar Array Simulator)

  • 웰라와타 투시타;서영태;최성진
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.118-126
    • /
    • 2020
  • A solar array simulator is a special power supply that regulates the output voltage and current to simulate the characteristics of a photovoltaic panel. The operating point of the panel is difficult to control with a single controller because of the non-linearity of the output curve, which is determined by the amount of irradiation, temperature, and panel material. In the conventional method, the output curve is divided into sections through the current and the voltage mode controls. It reduces the overall performance of the system due to the interchanging control mode. By using the single mode controller, the noise interference of the measured value and the stability of the control around the maximum power point were demonstrated. To solve these issues, this study proposes a new unified controller. The stability of the controller was analyzed along with operating principles, and performance improvement was experimentally verified.

Design and Implementation of Instantaneous Power Estimation Algorithm for Unified Power Conditioner

  • S., Sindhu;M.R., Sindhu;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.815-826
    • /
    • 2019
  • This paper discusses a simple control approach for a Unified Power Conditioner (UPC) system to achieve power quality compensation at the point of common coupling in distribution systems. The proposed Instantaneous Power Estimation Algorithm (IPEA) for shunt and series active power filters uses a simple mathematical concept that reduces the complexity in the design of the controller. The performance of a UPC is verified with a system subjected to voltage distortions, sags/swells and unbalanced loads using MATLAB/SIMULINK. The simulation study shows that a UPC with the proposed control algorithm can effectively compensate for voltage and current harmonics, unbalance and reactive power. The control algorithm is experimentally implemented using dSPACE DS1104 and its effectiveness has been verified.

국가 GIS와 연계를 위한 지적기준점의 세계측지계 변환 실험 (Experiment on Transform of Cadastral Control Points to the New Korea Geodetic Datum for Connecting with National Geographic Information System)

  • 송동섭;홍진상;윤홍식
    • 한국측량학회지
    • /
    • 제25권4호
    • /
    • pp.309-317
    • /
    • 2007
  • 우리나라의 지적기준점은 구소삼각원점, 특별소삼각원점, 특별도근측량원점 및 통일원점 등 다양한 원점체계를 기준으로 하고 있다. 이러한 다양한 원점체계를 가진 수치지적도는 통일원점을 기준으로 하는 국가 GIS 데이터와의 연계에 어려움을 가지고 있다. 본 연구에서는 구소삼각원점에 기준한 지적기준점 성과를 통일원점을 기준한 성과로 변환하기 위한 실험을 실시하였다. 변환 방법은 2차원 등각변환에 의한 변환 매개변수를 산출하고 이를 적용하여 간접변환한 성과를 GPS로 측량한 성과와 비교하였다. 또한 통일원점 기준의 지적기준점 성과를 세계측지계 기준의 성과로 변환하기 위한 최적합 실험을 실시하였다.

An Integrated Sequential Inference Approach for the Normal Mean

  • Almahmeed, M.A.;Hamdy, H.I.;Alzalzalah, Y.H.;Son, M.S.
    • Journal of the Korean Statistical Society
    • /
    • 제31권4호
    • /
    • pp.415-431
    • /
    • 2002
  • A unified framework for statistical inference for the mean of the normal distribution to derive point estimates, confidence intervals and statistical tests is proposed. This optimal design is justified after investigating the basic information and requirements that are possible and impossible to control when specifying practical and statistical requirements. Point estimation is only credible when viewed in the larger context of interval estimation, since the information required for optimal point estimation is unspecifiable. Triple sampling is proposed and justified as a reasonable sampling vehicle to achieve the specifiable requirements within the unified framework.

Implementation of IEEE 802.11ac Down-link MU-MIMO WLAN MAC using Unified Design Methodology

  • Chung, Chulho;Jung, Yunho;Kim, Jaeseok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.719-727
    • /
    • 2016
  • This paper proposes a unified medium access control (MAC) design methodology and presents the implementation of the IEEE 802.11ac down-link multi-user multi-input and multi-output wireless local area network MAC using the proposed design methodology. The proposed methodology employs unified code for both network simulation and system implementation. Because the unified code closely relates these two processes, the performance of the implemented MAC system can be estimated before implementation. The MAC architecture for an access point implemented using the proposed design methodology is verified on an ARM-based platform, and it is applied to a 65 nm CMOS library.

분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System)

  • 김희중;배병열;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.