• Title/Summary/Keyword: Unified Control

Search Result 538, Processing Time 0.027 seconds

Performance Analysis of UPFC by Simulation & Scaled Hardware Model Test (시뮬레이션과 축소모형에 의한 UPFC의 성능해석)

  • Han, Byung-Moon;Park, Ji-Yong;Jung, Jin-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2475-2477
    • /
    • 1999
  • This paper describes a simulation model and scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which adjust flexibly the active and reactive power flow through the ac transmission line. The design of control system was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. And both models are very effective to analyze the dynamic performance of the Unified Power Flow Controller.

  • PDF

A New Unified Method for Anti-windup and Bumpless Transfer (누적방지 무충돌전환을 위한 새로운 통합형 기법)

  • Kim, Tae-Shin;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.7
    • /
    • pp.655-660
    • /
    • 2009
  • In many real applications, the discrepancy problem between controller outputs and plant inputs or the abrupt variation problem of controller outputs can occur. These problems have a negative effect on control performance and stability. It is well-known that two phenomena called 'windup' and 'bump' cause these problems. So far these problems have been studied separately in each side of the anti-windup and the bumpless transfer. This paper proposes a new unified method combines the anti-windup and the bumpless transfer method using the linear quadratic minimization and a proper state space model representation for the anti-windup controller. The proposed method has a feature that it takes account of both the anti-windup and the bumpless transfer in one formula. Finally, we exemplify the performance of the proposed method via numerical examples using the controller switching between the anti-windup PID controller and the anti-windup LQ controller.

Unified Active Power Filter System of control Power Flow (전력조류 제어에 의한 병.직렬 능동전력필터 시스템)

  • Kang, Min-Hyung;Yang, Lee-Woo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.984-985
    • /
    • 2006
  • This paper presents control algorithms for unified active power filter. The algorithm is based in the performance function. The performance function is defined, and the compensation voltage reference is calculated for harmonics voltage and the compensation current reference is calculated for power factor. The proposed control algorithm can be applied to 3-phase 3-wire system and has a superior compensation characteristics for both harmonic current sources and harmonic voltage sources.

  • PDF

A Design on Robust Servo Controller Using ${\delta}$ - Operator (${\delta}$ - 연산자를 이용한 강인한 서보 제어기의 설계)

  • Hwang, Hyun-Joon;Kim, Jeong-Tek
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2602-2604
    • /
    • 2000
  • In this paper, we study robust linear optimal model following servo system in the presence of disturbances and parameter perturbations. A technique to directly design the generalized differential operator based unified control system that covers both differential operator based continuous time and delta operator based discrete time case is presented. The quadratic criterion function for a linear system is used to design the robust unified servo control system. This servo control system is designed by applying a simple genetic algorithm to follow the output of the reference model optimally. The characteristics of the proposed servo system are analysed and simulated to verify the robustness.

  • PDF

A Unified Framework for Transmitter Power Control in Cellular Radio Systems

  • Chai, Chin Choy;Lu, Ying;Chew, Yong Huat;Tjhung, Tjeng Thiang
    • ETRI Journal
    • /
    • v.26 no.5
    • /
    • pp.423-431
    • /
    • 2004
  • In earlier works on transmitter power control in cellular radio systems, the problem of whether a signal-to-interference ratio (SIR) threshold is achievable is determined by apparently different rules for homogeneous and heterogeneous SIR systems. In this paper, we present a unified and more universal framework for both cases. We also highlight the conditions under which a given SIR threshold vector for the heterogeneous SIR system is achievable, although so far there is no general solution to this problem.

  • PDF

DAB Converter Based on Unified High-Frequency Bipolar Buck-Boost Theory for Low Current Stress

  • Kan, Jia-rong;Yang, Yao-dong;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.431-442
    • /
    • 2019
  • This paper proposes a unified high-frequency bipolar buck-boost (UHFBB) control strategy for a dual-active-bridge (DAB), which is derived from the classical buck and boost DC/DC converter. It can achieve optimized current stress of the switches and soft switching in wider range. The UHFBB control strategy includes multi-control-variables, which can be achieved according to an algorithm derived from an accurate mathematical model. The design method for the parameters, such as the transformer turns ratio and the inductance, are shown. The current stress of the switches is analyzed for selecting an optimal inductor. The analysis is verified by the experimental results within a 500W prototype.

Design and Implementation of Instantaneous Power Estimation Algorithm for Unified Power Conditioner

  • S., Sindhu;M.R., Sindhu;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.815-826
    • /
    • 2019
  • This paper discusses a simple control approach for a Unified Power Conditioner (UPC) system to achieve power quality compensation at the point of common coupling in distribution systems. The proposed Instantaneous Power Estimation Algorithm (IPEA) for shunt and series active power filters uses a simple mathematical concept that reduces the complexity in the design of the controller. The performance of a UPC is verified with a system subjected to voltage distortions, sags/swells and unbalanced loads using MATLAB/SIMULINK. The simulation study shows that a UPC with the proposed control algorithm can effectively compensate for voltage and current harmonics, unbalance and reactive power. The control algorithm is experimentally implemented using dSPACE DS1104 and its effectiveness has been verified.

Unified approach to continuous and discrete Nehari problems

  • Kwon, Oh-Kyu;Lee, Koon-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.581-585
    • /
    • 1992
  • A unified approach to continuous and discrete-time Nehari problems, based on recently developed results by the authors for the one-block and Hankel-norm model reduction problems, is proposed. First, we derive discrete-time solutions in delta domain where numerical error is small and then we show that the derived form becomes same as the continuous form when the sampling interval approaches to zero.

  • PDF

Operation Analysis of Novel UPQC(Unified Power Quality Conditioner) without Series Injection Transformers (직렬주입변압기가 없는 새로운 UPQC(Unified Power Quality Conditioner)의 성능분석)

  • Kim H.J.;Bae B.Y.;Jon Y.S.;Han B.M.;Kim H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.251-255
    • /
    • 2003
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC/PSCAD, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The control strategy for the proposing UPQC was derived using the instantaneous power method. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems and can be utilized for the future distribution system.

  • PDF

The Compensating Unbalanced Source Voltages for Unified Active Power Filter System (직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상)

  • Kim, Young-Seok;Kang, Min-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.716-723
    • /
    • 2007
  • This paper suggests of a 3-phase 3-wire unified active power filter. The system is composed of a series active power filter and a parallel active power filter. The proposed series active power filter compensating unbalance source voltage and current harmonics of the parallel active power filter improves power factor. The proposed algorithm which improves for power factor and harmonic reduction are calculated by the performance function, and which compensates for the unbalanced source voltage is calculated based on the symmetrical component analysis. We composed a combined system of the series active power filter and parallel active power filter to confirm a validity of the proposed control methods. The effectiveness of the proposed algorithm is confirmed by the experiments.