• Title/Summary/Keyword: Unified Control

Search Result 535, Processing Time 0.023 seconds

Design of Unified Trench Gate Power MOSFET for Low on Resistance and Chip Efficiency (낮은 온저항과 칩 효율화를 위한 Unified Trench Gate Power MOSFET의 설계에 관한 연구)

  • Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.713-719
    • /
    • 2013
  • Power MOSFET operate voltage-driven devices, design to control the large power switching device for power supply, converter, motor control, etc. We have optimal designed planar and trench gate power MOSFET for high breakdown voltage and low on resistance. When we have designed $6,580{\mu}m{\times}5,680{\mu}m$ of chip size and 20 A current, on resistance of trench gate power MOSFET was low than planar gate power MOSFET. The on state voltage of trench gate power MOSFET was improved from 4.35 V to 3.7 V. At the same time, we have designed unified field limit ring for trench gate power MOFET. It is Junction Termination Edge type. As a result, we have obtained chip shrink effect and low on resistance because conventional field limit ring was convert to unify.

Unified Chassis Control with ESC and AFS under Lateral Tire Force Constraint on AFS (타이어 횡력 제한 조건 하에서 ESC와 AFS를 이용한 통합 섀시 제어)

  • Yim, Seongjin;Nam, Gi Hong;Lee, Ho Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.595-601
    • /
    • 2015
  • This paper presents an unified chassis control with electronic stability control (ESC) and active front steering (AFS) under lateral force constraint on AFS. When generating the control yaw moment, an optimization problem is formulated in order to determine the tire forces, generated by ESC and AFS. With Karush-Kuhn-Tucker optimality condition, the optimum tire forces can be algebraically calculated. On low friction road, the lateral force in front wheels is easily saturation. When saturated, AFS cannot generate the required control yaw moment. To cope with this problem, new constraint on the lateral tire force is added into the original optimization problem. To check the effectiveness of the propose method, simulation is performed on the vehicle simulation package, CarSim.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

On Fault Handling in Control Systems

  • Staroswiecki, Marcel
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.3
    • /
    • pp.296-305
    • /
    • 2008
  • Whereas fault diagnosis has been the subject of intensive research since the 1970s, the design of fault tolerant systems is a recent research field which does not set its foundations in a unified framework and does not use a unified vocabulary. As a contribution to this special issue, this paper proposes an ontology for the problem of Fault Handling, that embeds the problem of Fault Tolerance.

Fundamental study on Inverter-type Series and Shunt Compensator for Transmission System (송전계통의 인버터식 직.병렬 보상기에 관한 기초연구)

  • Han, Byung-Moon;Han, Hoo-Sek
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.425-433
    • /
    • 1999
  • This paper describes a simulation model and a scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which can flexibly adjust the active and reactive power flow through the ac transmission line. The design of control system was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. And both models are very effective to analyze the dynamic performance of the Unified Power Flow Controller.

  • PDF

Improvement of Responsivity of Unified Power Flow Controller in Digital Control System

  • Hamasaki, Shin-ichi;Miyazaki, Shinya;Takaki, Tsuyoshi;Tsuji, Mineo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.354-361
    • /
    • 2014
  • The Unified Power Flow Controller (UPFC) can flexibly manage power flow and maintain line voltage. The UPFC consists of two inverters in parallel side and series side. In parallel side, the reactive power can be compensated to improve the power factor. In series side, the voltage drop can be compensated to maintain proper line voltage. It is necessary for the operation in both sides to output the current and the voltage quickly and accurately. As the method for the UPFC control, the deadbeat control with state observer is applied. The deadbeat control is able to realize a quick response of the current and voltage control for only a sampling period compared with the general PI control. A principle and simulation results are presented in this paper.

Unified Control of Independent Braking and Steering Using Optimal Control Allocation Methods for Collision Avoidance (전(全)방향 충돌 회피를 위한 액츄에이터 최적 분배 알고리즘)

  • Kim, Kyuwon;Kim, Beomjun;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.2
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a unified control algorithm of independent braking and steering for collision avoidance. The desired motion of the vehicle in the yaw plane is determined using the probabilistic risk assessment method based on target state estimation. For the purpose of coordinating the independent braking and steering, a non-linear vehicle model has been developed, which describes the vehicle dynamics in the yaw plane in both linear and extended non-linear ranges of handling. A control allocation algorithm determines the control inputs that minimize the difference between the desired and actual vehicle motions, while satisfying all actuator constraints. The performance of the proposed control algorithm has been investigated via computer simulations conducted using the vehicle dynamics software CARSIM and Matlab/Simulink.

Experiments on Unify and Transform to the New Korea Geodetic Datum for Cadastral Control Points (지적기준점의 통일화 및 세계측지계 변환 실험)

  • Song, Dong-Seob;Yun, Hong-Sic;Hwang, Jin-Sang;Kim, Tae-Woo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.69-72
    • /
    • 2007
  • Cadastral control points in Korea are refered to various origins, for example an early separated small triangulation, a separated small triangulation, a separated control surveying origin and an unified origin. We determined transformation parameters from old origin to unified origin using 2D conformal transformation method. To evaluate of transformation accuracy, we compared with GPS field surveying results. And we experiment on coordinate transformations with unified results between the local geodetic datum and the new Korea geodetic datum.

  • PDF

A Design on Robust Model Following Servo System using $\delta$- Operator ($\delta$- 연산자를 이용한 강인한 모델 추종형 서보 시스템의 구성에 관한 연구)

  • Kim, Jeong-Taek;Lee, Hwa-Seok;Park, Seong-Jun;Chu, Yeong-Bae;Hwang, Hyeon-Jun;Lee, Yang-U;Park, Jun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.747-752
    • /
    • 1999
  • In the fast sampling limit, the delta operator model tends to the analog system model. This fundamental property of the delta operator model unifies continuous and discrete time control system. In this paper, we study robust linear optimal model following servo system in the presence of disturbances and parameter perturbations. A technique to directly design the generalized differential operator based unified control system that convers both differential operator based continuous time and delta operator based discrete time case is presented. The quadratic criterion function for a linear system is used to design the robust unified servo control. The characteristics of the proposed servo system are analysed and simulated to verify the robustness.

  • PDF

Performance Analysis of UPFC by Simulation & Scaled Hardware Model (시뮬레이션과 축소모형에 의한 UPFC의 성능해석)

  • Park, Ji-Yong;Baek, Seung-Taek;Kim, Hui-Jong;Han, Byeong-Mun;Han, Hak-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.579-586
    • /
    • 1999
  • This paper describes a simulation model and a scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which can flexibly adjust the active power flow through the ac transmission line. The design of control system for UPFC was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. Both models would be very effective for analyzing the dynamic performance of the Unified Power Flow Controller.

  • PDF