• Title/Summary/Keyword: Underground water condition

Search Result 189, Processing Time 0.028 seconds

A Field Case Research by Construction Management of Underground Excavation Construction Using Inverse Analysis Method (역해석 기법을 이용한 지하굴착공사의 시공관리에 관한 현장사례연구)

  • Park, Hyun-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1089-1095
    • /
    • 2014
  • In this study, we compared and analyzed the displacement of final excavation with measured value through an inverse analysis method used in urban excavation construction. We maximized the effectiveness of the inverse analysis method, and plan to achieve cost-effective and practical construction management in the field with identical conditions. As the first stage, we suggest an example of a field which has the inverse analysis method. We applied the inverse analysis method to three different fields on which construction and measuring were finished. Of these three fields, two fields showed a very satisfactory result. However, in one field, there were significant differences between the analysis and measured value. The result of our analysis indicated that, we should unite the conditions of the inverse analysis method and field construction. We need to thoughtfully reconsider the RANKINE earth pressure application in a triangle type. This is because the uniformity of earth pressure is made by its arching effect, in the condition of the displacement of lower underground occurring widely, which is differentiated with the earth pressure conditions of RANKINE, even if the slurry wall has stiffness. Also, when recalculating the soil parameter, we should emphasize the adhesion of the weathering zone, and give experimental consideration to ground water level.

Experimental study on pullout capacity on friction type steel pipe rock bolt to use elastic restoring force and existing rock bolts (탄성복원력을 이용한 마찰형 강관 록볼트 및 기존 록볼트에 대한 인발력 실험연구)

  • Moorak Son;Jihyun Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.459-468
    • /
    • 2023
  • In this study, an experiment on pullout capacity was conducted of rock bolts using grouting materials such as cement mortar and resin, which are widely used, and a newly proposed steel pipe friction type rock bolt using elastic restoring force, and the results were compared and analyzed. The experimental results showed that the pullout capacity on the rock bolts with cement mortar under a dry condition (no ground water) was relatively larger than the rock bolts with resin and the steel pipe. Nevertheless, the friction type steel pipe rock bolt to use elastic restoring force is expected to be useful in the field particularly where groundwater exists and it affects the loss and curing of grouting materials such as cement mortar or resin. In addition, it was found to have the advantage of being easy and quick to install.

Studies on establishment rate of direct seeded rice in relay intercropping system

  • Maki, Natsumi;Yasumoto, Satoko;Kojima, Makoto;Ohshita, Yasuo
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.186-186
    • /
    • 2017
  • Relay intercropping system of direct seeded rice and winter cereal is labor saving cultivation and has high land use efficiency in Japan. In this system, rice seeds are direct seeded into inter-row space of winter cereals (wheat or barley) in March or April. If the direct seeding of rice is conducted before stem elongation phase or using suitable seeder, these are little effect to yield of winter cereals. Though the seeds are generally thiuram treated, it's a matter that seedling establishment rate (SER) of direct seeded rice is low and unstable. The cause of low SER has not been revealed. In present study, with the aim to reveal causes of low SER, we conducted experiments and investigated the SER, and analyzed some factors that might affect SER. Experiment1: In 2015, 2016, we buried rice seeds underground, and investigated the transition of the seed survival rates (SSR). Seeds were thiuram-treated or non-treated. In 2 periods, SSR of thiuram-treated seeds were significantly higher than non-treated seeds. In 2016, thiuram-treated seeds were high in SSR (almost 75%) at April 30th, but low SER (10~27%) after harvest of winter cereals. Therefore, almost all of seed death might have been happen after germination. Analysis 1: We investigated the SER and cultivation conditions in Ibaraki pref. for several years. Meteorological factors were referred from the nearest point of AMeDAS. From mean temperature (MT) among 5days after and before the day, we divided the period of seeding ~June 20 to phase1~4. We defined each phase as below; Phase1: $MT{\leq}10^{\circ}C$, Phase2: $10^{\circ}C<MT{\leq}15^{\circ}C$, Phase3:$15^{\circ}C<MT{\leq}20^{\circ}C$, Phase4: $MT>20^{\circ}C$. We analyzed the correlation of SER and meteorological factors by each phase. Total number of days in phase 1~4 was significantly negative correlated with SER. In phase1, total rain fall and number of soil wetting days were significantly negative correlated with SER. In phase2~4, only MT was significantly positive correlated with SER. This result suggested that rainfalls in phase1 declined seed vigor to emergence from soil surface, by repeated water absorption and re-dry. From these present studies, it was suggested that one of factors of low SER of direct seeded rice in relay intercropping system is changing of water condition by rainfalls in phase1 ($MT{\leq}10^{\circ}C$). To improve SER, it's necessary to consider something seed treatments such as prevent water absorption during phase1. However, 58~60% of seeds seemed to die during May. It's suggested that, if seeds are thiuram treated, almost all of seeds can germinate underground, but the seed vigor to emergence from soil surface are insufficient. Further studies are needed to reveal the rest causes that is happening during emergence from soil surface.

  • PDF

A Study on the Analysis of Monitoring Settlement Considering the History of the Groundwater Level in the Dredged Landfill Area Affected by Algae (조류의 영향을 받는 준설매립지역에서 지하수위 이력을 고려한 계측침하 분석에 관한 연구)

  • Jang, Ji-Gun;Son, Su-Won;Hong, Seok-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.7
    • /
    • pp.13-23
    • /
    • 2021
  • If roads, bridges, buildings, etc. are built on the ground with soft clay or organic soil, there may be a lot of problems in geotechnical engineering such as settlement and stability due to the large settlement and lack of bearing capacity. In extreme cases, it may appear due to shear failure or collapse of the constructed structure, so a ground improvement method is indispensable to increase the strength of the ground and to suppress settlement. In this study, the settlement according to each groundwater level condition was analyzed using the measurement results for the groundwater level conditions, one of the important factors in predicting the settlement in dredged and reclaimed ground, and the groundwater level conditions applied to the settlement analysis were proposed by comparing it with settlement generated 5 years after construction. As a result of the analysis, it is judged that it is reasonable to apply the measured groundwater level during construction and the low water ordinary neap tide (L.W.O.N.T) during load application for the groundwater level in the settlement analysis. In addition, in the case of the dredged and reclaimed ground, it is estimated that the water pressure acting on the clay layer is nonlinear, as the result of the observations of the head of water at the observation points above and below the in-situ clay layer were different.

Performance Evaluation of Closed Co-axial Ground Heat Exchanger in the case of 2000m-Depth Single Well (2000m 단일 시추공에서 밀폐 동축 방식 지중 열교환기의 취득온도 성능평가)

  • Ryoo, Yeon-Su;Kim, Jae-Hyeok;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.83-92
    • /
    • 2016
  • The Korean government has been making efforts to use renewable energy to reduce the consumption of fossil fuels for the heating system in greenhouses. The number of greenhouses that installed a geothermal heat pump system is 201 EA with the volume of 132.8 ha and 108,467kW from 2010-2014. The geothermal system, called a shallow geothermal system, with the temperature of $10-20^{\circ}C$ has accessories composed of a BHE and heat pump. Moreover, it is necessary to have a wide area to install the BHE and to drill to the depth of 200 m. On the other hand, even though the deep geothermal system needs a high drilling cost to obtain the temperature of $40-150^{\circ}C$, the system has the advantages of the small area required for the BHE and operation without a heat pump. In this study, the temperature of the return water and heat capacity were measured to obtain the geothermal energy efficiently on the condition of the water flow being changed in the BHE. The temperature according to the return water changes through the heat conduction based on the increase of ground temperature up to the underground depth has been calculated to conduct a simulation and is compared with the field experiment test results.

Numerical Analysis for the Effect of Ground and Groundwater Conditions on the Performance of Ground Source Heat Pump Systems (토양 및 지하수 조건이 지열공조시스템의 성능에 미치는 영향에 관한 수치 해석적 연구)

  • Nam, Yu-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.321-326
    • /
    • 2011
  • Recently, ground source heat pump (GSHP) systems have been introduced in many modem buildings which use the annually stable characteristic of underground temperature as one of the renewable energy uses. However, all of GSHP systems cannot achieve high level of energy efficiency and energy-saving, because their performance significantly depends on thermal properties of soil, the condition of groundwater, building loads, etc. In this research, the effect of thermal properties of soil on the performance of GSHP systems has been estimated by a numerical simulation which is coupled with ground heat and water transfer model, ground heat exchanger model and surface heat balance model. The thermal conductivity of soil, the type of soil and the velocity of groundwater flow were used as the calculation parameter in the simulation. A numerical model with a ground heat exchanger was used in the calculation and, their effect on the system performance was estimated through the sensitivity analysis with the developed simulation tool. In the result of simulation, it founds that the faster groundwater flow and the higher heat conductivity the ground has, the more heat exchange rate the system in the site can achieve.

Electrical properties of XLPE and Semiconductor Materials for Power Cable (전력케이블의 가교폴리에틸렌과 반도전 재료의 전기적 특성)

  • Lee, Ju-Hong;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.207-210
    • /
    • 2008
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. We studied effects for impurities and water for semiconductor shield through a dielectric properties experiment to estimate performance of insulating materials in power cable. Capacitance and $tan{\delta}$ of 22[kV], 154[kV] were 53/43[pF] and $7.4{\times}10^{-4}$, $2.1510^{-4}$. In these results, the trend was increased with the increase of temperature. The tan6 of XLPE/semiconductor layer was increased as compared with that of XLPE. Dielectric properties reliability of tan6 was small. Also, To improve mean-life and reliability of power cable in this study, we have investigated chemical properties showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Chemical properties of specimens was measured by FT-ATR (Fourier Transform Attenuated Total Reflectance). The condition of specimens was a solid sheet. We could observe functional group (C=O, carbonyl group) of specimens through FT-ATR. From these experimental result, the concentration of functional group (C=O) was high according to increasing the content of carbon black. We could know EEA was excellent more than other specimens from above experimental results.

  • PDF

Scaled Test on the Behavior of the Toe of Drilled Shaft on Rock Mass (암반에 근입된 말뚝의 선단 거동 특성에 관한 축소모형시험 연구)

  • Park, Woan-Suh;Choi, Se-Keun;Jeon, Seok-Won;Han, Yong-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1166-1171
    • /
    • 2008
  • Despite of the increasing number of the application of drilled shaft piles in construction site, most studies on pile capacity have been focused on the side shear resistance. But it is common that the drilled shaft is socketed on the rock so as to use its bearing resistance. The prediction of the end movement and characteristics of the bearing capacity of the pile is great important as well. Therefore, a series of scaled model tests were carried out in order to study the characteristics of the bearing capacity on rock mass. The material of the test block was cement mortar which was mixed with sand, cement and water, and the size of a test block size was $240{\times}240{\times}240mm$. The axial load was applied by a miniaturized pile of 45mm in diameter and flat jacks and steel plate were used for confinement to simulate the real underground loading conditions. The relation of load-displacement was measured in various different conditions of rock mass such as strength, discontinuity of the rock mass and in-situ stress, so q-w curves of the end of the pile were presented for each condition.

  • PDF

Experimental approach to evaluate weathering condition of granite using electrical resistivity

  • Oh, Tae-Min;Cho, Gye-Chun;Son, Thai An;Ryu, Hee-Hwan;Lee, Changho
    • Geomechanics and Engineering
    • /
    • v.8 no.5
    • /
    • pp.675-685
    • /
    • 2015
  • Weathering is the breaking/cutting down process of rocks due to physical and chemical processes in natural as well as artificial environment including $CO_2$ injection for storage in the sediment, or natural resource recovery process. This study suggests an alternative method to estimate the degree of weathering for granites. A series of laboratory and field experiments are performed to measure electrical resistivities on various rock samples experienced different degrees of weathering and their residual soils under different saturation conditions. It is found that the normalized electrical resistivity increases with a decrease in water absorption and the saturation. Simple boundaries are suggested to identify the weathering degree of granites, based on limited data. Field test results for three sites confirm that the suggested method could be estimated well the degree of weathering of granites compared with the other methods suggested previously. Although further research is required, this study suggests that an electrical resistivity could be an effective approach to estimate the degree of weathering of granites compared with the other methods suggested previously.

A Study on the Sustainable Characteristics of the London City Hall (런던 시청사의 지속가능적 특성에 관한 연구)

  • Chung, Tae-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.3-12
    • /
    • 2011
  • The purpose of this study is to analyze the sustainable characteristics of London city hall designed by Norman Foster. The most important part of sustainable architecture might be the energy reduction including minimizing CO$_2$ emission but social and economical aspects of sustainability should not be neglected. London City Hall as a successful example of sustainable architecture depends its success on the harmony of social, environmental and economical aspects of sustainability. Social sustainability in London City Hall appears on appropriateness and public good in the facility. London City Hall act as a symbol of redevelopment and civic community. Environmental sustainability of London City Hall summarized as using unique building form, double skin and underground water cooling system for the purpose of energy saving. Computer modeling technology was introduced to save construction cost for economic aspect of sustainability. Rational configuration of mechanical system strengthen the durability of facility. In case of London City Hall, the function of building, site condition and architectural concept fulfill the every aspects of sustainability in architecture. Besides these conditions, Foster applied sustainability to London City Hall as active and concrete design concept to complete its design goals.