• Title/Summary/Keyword: Underground facility

Search Result 379, Processing Time 0.03 seconds

A study on the Water Mist Fire Suppression Performance (미세 물 분무 소화 성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF

A Study on the Unification of The Grounding System of SeoulMetro due to Ageing (서울메트로 접지시스템의 경년변화에 따른 개선 접지 기준)

  • Min Byung-Hoon;Kim Gyunl-Sig;Chung Young-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.394-400
    • /
    • 2006
  • Since Seoulmetro built the first line of electric railway at seoul 1974, the passengers of railway have been increased rapidly, and electric railway requires more electric power for the greater capacity of transport. It is important that we prevent the accidents related with the subway, because all systems of subway are constructed in artificial underground structure. Since the previous versions of the earth system were built to meet the old standards of the electric facility for the lightning, some accidents related with the DC earth fault are causing secondary damages to the electric equipments. So, the old grounding system must be improved, and new standards of grounding system are required. We compare the grounding systems of the domestic railway corporations and the accidents that are related with the grounding systems. And we give ideas to improve the grounding systems and present standards which are suitable to electric railway.

A Capacity of Refuge area in Multiple Occupancy Building with Underground Facility (지하연계복합건축물의 피난 안전구역 면적 산정)

  • Kim, Jong-Sung;Kim, Woon-Hyung;Lee, Yong-Jae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.272-276
    • /
    • 2011
  • 최근 발생한 부산 해운대 화재 이후 피난 활동이 제한적인 고층 건축물의 화재 안전에 대한 관심이 증대되고 있다. 그러나 현행 규정은 50층 이상의 초고층 건축물을 대상으로 하고 있으며 상대적으로 준 초고층 건축물에 대한 제도적 기반과 연구가 미비한 실정이다. 따라서 본 연구에서는 지하연계복합건축물에 관한 피난 안전구역면적 산정 기준에 대한 적용성을 분석하고자 국외의 관련 기준과 비교 분석하였다. 그 결과, 수용 인원에 관한 기준은 홍콩, 한국, 싱가포르, 중국 순으로 강화 적용하고 있으며 피난안전구역의 면적은 싱가포르의 경우 전체 수용 인원의 50% 이상과 1명당 $0.3m^2$을 전제로 하는 피난안전구역의 면적 기준이 국내의 각 층별 1/10의 면적의 합과 동일한 것으로 분석되었다.

  • PDF

The stability analysis on large sectional tunnel station considering construction steps (시공단계를 고려한 대단면 정거장 터널 안정성 해석)

  • Kang, Eun-Gu;Kim, Yang-Woon;Ahn, Kyeong-Cheol;Han, Myeong-Sik
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1062-1068
    • /
    • 2009
  • Urban construction has numerous difficulties due to ground weakness and various complaints from third party, so it is not economically efficient and constructability is not favorable. Therefore, underground, which has good ground conditions, was used for construction field and facilities such as stations, and they are scaled up to enhance accommodation of facility limitation and function of stations. Large section tunnel station construction has numerous risk factors such as work boundary of excavation equipment, a relaxation of stress concentration, a safety plan of tunnel stability, and so on. Therefore, by using large section tunnel station stability analysis considering construction step, we expect to analyze the latent problem during construction, and to stabilize a future project plan of a large section structure design by using an auxiliary method and a support design.

  • PDF

A Study on the Performance of Water Mist Spray Fire Protection System (미세물분무 소화성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱;최현호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.572-578
    • /
    • 2003
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was attributed to the cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

A Method of Measuring Location Coordinates for Underground Facility Management (지하시설물 관리를 위한 위치좌표 확보 방안)

  • Seo, Dong-Seob;Kim, Gun-Bae;Baik, Song-Hoon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.315-318
    • /
    • 2008
  • 유비쿼터스 도시의 개념이 등장하면서 도시관리에 대한 중요성이 점차 부각되어가고 있다. 특히 지하시설물에 대한 안전한 관리는 안전한 도시를 표방하는 유시티 에서는 없어서는 안될 중요한 공공서비스라 할 수 있다. 최근 이러한 도시의 지하시설물의 안전한 관리를 위한 체계적인 관리 방안에 대한 연구가 국토해양부를 중심으로 활발히 이루어지고 있다. 지하시설물의 특성상 안전하고 체계적인 관리를 위해서는 무엇보다 지하시설물에 대한 정확한 위치좌표를 알아야 하고 지하시설물에 일어나는 변화에 대한 정보를 수집하기 위해 센서적용기술을 필요로 한다. 본 논문에서는 유비쿼터스 도시 내 지하시설물 구축과정에서의 절대위치확보 방안과 각 지하매설물별 특성을 고려한 센서적용방안에 대한 내용을 기술하였다.

  • PDF

A study on sensor network structure for underground Facility management of city (도시 지하시설물 관리에 적합한 센서 네트워크 구성에 관한 연구)

  • Kim, Gun-Bae;Seo, Dong-Seob;Baik, Song-Hoon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.83-86
    • /
    • 2008
  • 도시의 많은 시설물을 좀더 지능화된 체계로 관리하기 위한 수단으로 RFID/USN을 이용한 솔루션이 다양하게 제안되고 있다. 최근에 상하수도, 전력, 가스, 통신 관로 등 지하시설물 관리분야도 기존의 도면 관리체계에서 센서를 이용한 실시간 운영관리시스템 형태로의 진화를 시도하고 있다. USN은 일반적으로 무선전송을 기반으로 발전시킨 기술로서 이를 지하 매설물 센서네트워크에 적용할 경우 여러 가지 제약사항이 따르게 된다. 전자기파의 물리적 특성상 지하에서는 통신이 어렵기 때문에 이를 보완할 수 있는 적용기술 및 시설물 분포에 맞는 네트워크 토폴로지 또 싱크 노드의 물리적 설치공간 확보 및 구동전력 공급 등 현장에서 부딪히는 여러 가지 네트워크 구축에 관련된 현안사항에 대하여 그 해결방법에 대하여 기술하였다.

  • PDF

Implementation of a Modified SQI for the Preprocessing of Magnetic Flux Leakage Signal

  • Oh, Bok-Jin;Choi, Doo-Hyun
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.357-360
    • /
    • 2013
  • A modified SQI method using magnetic leakage flux (MFL) signal for underground gas pipelines' defect detection and characterization is presented in this paper. Raw signals gathered using MFL signals include many unexpected noises and high frequency signals, uneven background signals, signals caused by real defects, etc. The MFL signals of defect free pipelines primarily consist of two kinds of signals, uneven low frequency signals and uncertain high frequency noises. Leakage flux signals caused by defects are added to the case of pipelines having defects. Even though the SQI (Self Quotient Image) is a useful tool to gradually remove the varying backgrounds as well as to characterize the defects, it uses the division and floating point operations. A modified SQI having low computational complexity without time-consuming division operations is presented in this paper. By using defects carved in real pipelines in the pipeline simulation facility (PSF) and real MFL data, the performance of the proposed method is compared with that of the original SQI.

MV Cable Failure Statistics Analysis and Failure Rate Utilization Method of Prioritization of Diagnosis Targets (지중 배전용케이블 고장통계 분석 및 고장률 활용 진단대상 우선순위 선정방법)

  • Cho, Chong-Eun;Lee, On-You;Kim, Sang-Bong;Kim, Kang-Sik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.263-268
    • /
    • 2021
  • This paper statistically analyzes the time required for each failure cause and describes a diagnostic method for 159 reports of failure analysis of MV cables that occurred in the distribution system of KEPCO over the past 18 years. In addition, the manufacturer's failure rate compared to 100C-km was calculated using 381 cases of MV cable deterioration failure between 2008 and 2020. It is hoped that this paper will help those in charge of maintaining underground facilities at the business office to use the failure rate to prioritize facility diagnosis.

An Implementation of Location based Information System for Underground Facility using Mapping of NMEA Sentence and RFID Identification code (NMEA Sentence와 RFID 식별코드의 매핑을 이용한 위치기반 지하매설물 정보시스템의 구현)

  • Kim, Min-Ho;Hong, In-Sik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.640-643
    • /
    • 2008
  • 현재 우리나라는 좁은 국토와 도시 집중화로 인해 급증하고 있는 지하매설물의 체계적인 관리가 어느 때보다 요구되고 있다. 그러나 다른 분야에서 빠르게 진행되고 있는 전산화 및 정보화 작업에 비해 상대적으로 더딘 지리정보체계 구축으로 지하매설물 관리를 위한 정보시스템이 미비한 상태이다. 이는 지리정보체계 구축 방법에 어려움과 소요되는 인력, 비용, 시간 등이 크기 때문으로 판단된다. 본 논문에서는 GPS와 능동형 RFID를 이용한 위치기반 지하매설물 정보시스템의 구현을 기술하고 시뮬레이션하였다. 이 시스템은 GPS NMEA Sentence의 위치정보와 능동형 RFID의 인식정보를 결합한 데이터를 이용하여 정확하고 체계적인 지하매설물 정보 구축이 가능하고, 효율적인 지하매설물 관리를 위한 인터페이스를 제공한다.