• 제목/요약/키워드: Underground distribution cable

검색결과 104건 처리시간 0.025초

지중배전케이블 외피용 컴파운드의 이온투과 특성 비교 (Effect of Ionic Impurities in Materials for CN/CV Underground Distribution Power Cable Jackets)

  • 김동명;권태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.167-168
    • /
    • 2008
  • The permeation of $Ca^{2+}$ ions through the materials such as polyvinyl chloride (PVC) and non-halogenated flame retardant cross linked polyolefin (FR-XLPO) used for CN-CV underground distribution power cable jackets was investigated. The permeation of $Ca^{2+}$ ions was found to increase with the increase of time. The FR-XLPO showed higher permeation of $Ca^{2+}$ ions, by a factor of about two, than the PVC. This was explained by the destruction of structural integrity caused by mixing a large amount of mineral flame retardant such as $Mg(OH)_2$ used to impart non-flame ability to the jacket material.

  • PDF

시공단계별 영향을 고려한 터널 전력구의 유한요소해석 (Finite Element Analysis of Underground Electrical Power Cable Structures Considering the Effects of Construction Sequence)

  • 김선훈
    • 한국전산구조공학회논문집
    • /
    • 제26권2호
    • /
    • pp.147-155
    • /
    • 2013
  • 본 논문에서는 도심지 지하에 터널 전력구를 건설하는 경우 시공단계별 영향을 고려한 구조해석을 수행하였다. 해석대상의 도심지 지하에는 여러 종류의 다양한 라이프라인 구조체가 설치되어 있다. 터널전력구의 구조해석에는 지반체의 유한요소해석 프로그램인 MPDAP을 사용하였다. 라이프라인 구조체와 터널 전력구 사이의 이격거리가 가장 작은 대표적인 3개의 단면에 대하여 구조해석을 수행하였다. 터널의 굴착단계별 유한요소해석에서 발생되는 평형불균형성 문제는 평형섭동개념을 적용하여 해결하였다. 또한 터널 굴착에 의한 시간의존 변형의 영향은 하중분담율을 사용하여 시공단계별로 고려하였다. 본 연구에서 검토한 3개의 대표단면에서는 터널 전력구 주변 지반체에서 발생하는 최대변위값은 허용변위값이내를 보여주었다.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전의 타당성 평가 (Suitability Evaluation on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;이종범;김용갑;송일근;김병숙
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2135-2142
    • /
    • 2010
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as locations and current types of lightning stroke. Overvoltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

배전계통 적용을 위한 초전도케이블의 전기적 특성요건과 규격검토 (A Suggestion of Standards and factors applied Distributed Power System to electrical characteristic of HTS cable)

  • 이현철;이근준;황시돌;손승호;임지현;정성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.165_166
    • /
    • 2009
  • A HTS(High Temperature Superconductor) Cable is regarded as the most underground power to respond higher power density delivery system. This paper discussed electrical characteristic and standards of HTS Cable system. Various HTS cable characteristics are examined[3-5], ad compared with XLPE cable characteristics on possible distribution system environment. HTS cable is required to stabilize thermal condition for superconducting status, possible improper operating condition which affects quench, unbalanced, and harmonics impacts are discussed. HTS cable is customer designed cable which shall be implemented in special requirement of power system, the standard origination process requires to establish a series of methodology including design manufacturing, testing and installation.

  • PDF

국내 지중배전시스템의 서어지 보호방안 (Surge Protection Method of the Underground Distribution System in Korea)

  • 이재봉;정연하;박철배
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.84-88
    • /
    • 2008
  • 본 논문은 2007년에 게재된 "지중배전케이블의 서어지 전파특성 실증연구"를 통해 검증된 서어지 전파특성을 고려하여 피뢰기를 이용한 보호효과를 ATP-EMTP(Electro-Magnetic Transient Program)로 해석하고 국내 상황에 적합한 보호방법을 제시하고자 한다. 국내 지중배전시스템은 입상주에 설치된 피뢰기에 의해 보호되고 있지만 서어지가 케이블의 말단 개방점에서 두배 정도로 상승하여 배전설비의 절연을 위협할 수 있으므로 추가적인 보호 방법이 필요하다. 본 논문에서 추가적인 보호 방법으로 제안하는 스카우트 방법은 입상주 피뢰기 전 후단 전주에 피뢰기를 추가 설치하는 방법으로 지중배전선로에 피뢰기를 설치하기 곤란한 경우나 지중배전선로용 엘보우 피뢰기를 개발하여 적용하는 것보다 경제성에서 유리하고 설치 및 유지보수 측면에서도 효과적일 것으로 기대된다.

345kV CV 케이블 접속함의 Proto Type 선정 (Determination of Proto Type for 345kV CV Cable Accessories)

  • 이수길;김인태;손시호;최수걸;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

154 kV 지중송전선로의 고정용 금구류에서 발생하는 와전류 및 히스테리시스 손실 분포 해석 (Analysis of Eddy Current and Hysteresis Loss Distribution from Fixing Structure of 154 kV Underground Transmission Cable)

  • 송혜은;임상현;김경윤;박관수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권1호
    • /
    • pp.9-12
    • /
    • 2018
  • 최근 도시미관과 편리성을 위해 지중송전선로의 사용이 확대되고 있다. 하지만 지중송전선로에서 발생하는 손실, 특히 24시간 상시 운영되는 3상 케이블을 지지하고 있는 금구류에서 발생하는 손실에 관한 연구는 부족하다. 케이블지지 금구류는 도전율과 투자율을 가지는 재질로 구성되어지기 때문에 케이블에 흐르는 전류에 의한 자기장 때문에 와전류 및 히스테리시스 손실이 발생하게 된다. 이 때 발생하는 손실은 전력 에너지 전달 효율에 악영향을 미치기 때문에 손실에 대한 연구가 필요하다. 따라서 본 논문에서는 3차원 유한요소해석을 통하여 케이블의 주변 금구류에서 발생하는 와전류 및 히스테리시스 손실에 대하여 분석하였다.

지하구 미분무수 소화설비 적용에 관한 연구 (An Application of the Water Mist System for Underground Utility Tunnel)

  • 김운형;김종훈;박승민;김태수;민인홍;전동일;김상욱
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.66-76
    • /
    • 2002
  • 본 연구는 지하구 미분무수 소화설비 적용에 관한 것으로, 화재 초기에 신속한 소화를 통한 케이블 열적손상의 최소화와 신속한 본래 기능의 회복을 위한 소화 시스템의 최적화에 그 목적이 있으며, 이를 위해 미분무수 노즐개발을 위한 화재실험을 수행하였다. 실험은 2.5m(H)$\times$2.5m(W)$\times$25m(D)의 콘크리트 지하구에서 소화설비가 작동되지 않는 경우와 2가지 종류의 미분무수노즐이 적용되는 경우를 수행하였다. 실험 결과 소화설비의 개입이 없는 경우, 2분 이내에 열적 변형에 의한 치명적인 손상을 입었으며, 2~3분 경과 후 케이블의 내부까지 손상되었다. 노즐적용실험의 결과, 타입 1(입자분포 약 470$\mu{m}$)노즐과 타입 2(입자분포 약 650$\mu{m}$) 노즐은 모두 케이블의 피해 온도제어($4000^{\circ}c$ 이하)를 만족하였다. 실험을 통하여 지하구 공간특성에 적합한 미분무수 헤드의 특성을 설정할 수 있었으며, 그 성능을 입증할 수 있었다.

전력케이블 절연재료의 내부결함에 따른 전기적 특성 (Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable.)

  • 최상기;김탁용;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF

실계통 345kV 지중송전선 대칭좌표 임피던스의 해석 (Analysis of Sequence Impedances of 345kV Cable Transmission Systems)

  • 최종기;안용호;윤용범;오세일;곽양호;이명희
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.