• Title/Summary/Keyword: Underground Water

Search Result 1,340, Processing Time 0.028 seconds

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture (건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립)

  • Hwang, Min-Kyu;Cho, Woo-Jin;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Assessment of Variable Characteristics in Water Quality of the Supply Systems in the Building (건축물내 급수설비의 수질변화 특성과 영향력 평가)

  • Lee, H.D.;Hwang, J.W.;Bae, C.H.;Kim, S.J.
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.313-320
    • /
    • 2004
  • In this study, variable characteristics of drinking water and the influences on underground water reservoirs, rooftop water tanks, and service water pipes in the building were assessed. The influence of underground water reservoir material and water capacity on water quality also were assessed. The results are the following as; First of all, the drinking water passing through underground water reservoirs or service water pipes in the building, averagely metal component concentration more increased from percent of 41.3 to percent of 74.2 totally than other items of water quality. On the other hand, both residual chlorine and total solid highly decreased 65.6 percent and 35.3 percent, respectively. Therefore, it was thought that water quality could be getting worse for microorganism re-growth by residual chlorine reduction, and total solid also could be a cause for extraneous matters accumulated in water reservoir. Secondly, the variations on water quality of each stage for water supply system in the building were higher in water service pipes connected from rooftop water tanks to the tap than in underground water reservoirs. In addition to, among of twelve items on water quality, ten items on water quality except dissolved oxygen and residual chlorine increased. Therefore, it was thought that the influence of water service pipes connected from rooftop water tanks to the tap on water quality were higher than other stages of water supply system in the building. Thirdly, in case of materials of underground water reservoir, it was likely that the variation on water quality by stainless steel and concrete materials got some similar. In case of water capacity, the variations on water quality of underground water reservoirs over $1,000m^3$ higher than those under $1,000m^3$. That reasons was likely that the retention time(49.72 hours averagely) of underground water reservoirs over $1,000m^3$ was two times longer than it of those under $1,000m^3$(23.37 hours). Therefore, it was thought that the influence on water quality by materials were some similar, but in case of water capacity, the influence of underground water reservoirs were higher.

Corrosion behavior of coated steel pipes for water works with water content of soil (토양의 함수율에 빠른 상수도용 도복장 강관의 부식거동에 관한 연구)

  • Park, Kyung-Wha;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Ha, Yoon-Cheol;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.227-229
    • /
    • 2004
  • The corrosion rate of buried steel pipes for water works was investigated under soil environment. Steel pipe shows various characteristics caused by complicated environment condition of underground and especially the corrosion rate of it depends on the resistivity of soil controlled by content of water. In this paper, the corrosion behavior of steel pipe was observed by polarization test under soil and the silica sand in the water content range of 0-50%. Generally it is well known that the resistivity of soil decreased rapidly over 15% water content. In fact the corrosion rate, corrosion potential, and corrosion consumption (MPY) of steel pipe were shown very different aspects within 20% water content.

  • PDF

Remote Control of Pumping System for Underground Water Pollution and Running Dry Prevention Using Ubiquitous (유비쿼터스를 이용한 지하수 오염과 고갈방지를 위한 펌핑시스템의 원격제어)

  • Tack, Han Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.3
    • /
    • pp.9-15
    • /
    • 2013
  • This paper was development of remote controller of pumping system by using ubiquitous for underground water contamination prevention in the area of glasshouse facility. This paper automatically controls from to temperature and humidity for pumping sprinkler at water hanging cultivation. This prevents indiscreetive development of underground water, and prevents damage of environmental pollution without complementary measures in case of water lacked humble-void. The result of this research, confirms decrease of electrical fee, prevention of indiscreet underground water usage and its drying up thought optimum farm products management and pumping control system.

Safety Monitoring Sensor for Underground Subsidence Risk Assessment Surrounding Water Pipeline (상수도관로의 주변 지반침하 위험도 평가를 위한 안전감시 센서)

  • Kwak, Pill-Jae;Park, Sang-Hyuk;Choi, Chang-Ho;Lee, Hyun-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.306-310
    • /
    • 2015
  • IoT(Internet of Things) based underground risk assessment system surrounding water pipeline enables an advanced monitoring and prediction for unexpected underground hazards such as abrupt road-side subsidence and urban sinkholes due to a leak in water pipeline. For the development of successful assessment technology, the PSU(Water Pipeline Safety Unit) which detects the leakage and movement of water pipes. Then, the IoT-based underground risk assessment system surrounding water pipeline will be proposed. The system consists of early detection tools for underground events and correspondence services, by analyzing leakage and movement data collected from PSU. These methods must be continuous and reliable, and cover certain block area ranging a few kilometers, for properly applying to regional water supply changes.

Microbiological Study of Aquarium Water around the Costal Sanitary landfill Sites (매립지하해수의 위생학적 고찰)

  • 조용순;이인자
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.73-82
    • /
    • 1990
  • This study was conducted to investigate the vibrio sap contamination of aquarium (water) in Incheon Area The results obtained were as follows : 1. V. parahaemolyticus was detected 20.4% at samples of aquarium water and not detected at underground water 2. V. unlnificus was not detected at all samples 3. Underground water was similar to aquarium water on pH and the concentration of salt 4. Underground water proved it's safety bacteriologically 5. V. parahaemolyticus was common in the sea water between July to October.

  • PDF

Development of an Application System for Efficient Management of Underground Water Supply Facility - Pilot Study in Chonju City - (상수도 지하시설물의 효율적 관리를 위한 응용시스템 개발 -전주시를 대상으로-)

  • 오권호;진철하;이근상;정승현;조기성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.111-120
    • /
    • 2000
  • Water, waste, electric and gas facilities are urban based facilities that needed in our life and are often located in underground. Therefore, underground facilities are more difficult to manage efficiently than ground facilities. It is needed to carry out survey/probe into underground facilities and to build database in order to prevent city-misfortunes being occurred because of negligent management and in order to minimize budget-waste and a traffic jam according to repetition of road excavation constructions. Also, the development of application system is required to manage efficiently underground facility. Chonju city has launched underground water supply facility computerizing project as a part of National Geographic Information System project until December 1998 and executed survey/probe into 402.89 km water supply that is 80 mm up inside central town area 39.6 $km^2$. Also, chonju city built database into 537 km water supply that is 80 mm below based on water supply card without other survey/probe works. Also, existing work process each department is changed into GIS applied work process and underground water supply facility management system is developed by its work process basis. Water supply underground facility management system that is developed is composed of sub-system like base-map management, water supply inspect, water supply management and water supply inquiry, construction work management, administration management and map management. This research presents the procedure and method of underground water supply facility survey/probe and problem being occurred during survey/probe procedure and also show the functions of each sub-systems composing underground water supply facility management system.

  • PDF