• Title/Summary/Keyword: Under-ventilation

검색결과 438건 처리시간 0.025초

팁페이파 및 필터권지 기공도 조합이 제품담배 공기희석율에 미치는 영향 (Effects of Tipping Paper and Plug Wrap on Cigarette Filter Ventilation)

  • 김정열;김종열;신창호
    • 한국연초학회지
    • /
    • 제23권1호
    • /
    • pp.60-64
    • /
    • 2001
  • The variability of a ventilated filter cigarette depends on the details of its construction and one properties of its components and the variations in filter ventilation is effected by many factors such as tobacco column pressure drop, filter pressure drop, tipping paper and plug wrap permeability, and vent position. In this study, the effects of combination of tipping paper and plug wrap on filter ventilation of cigarettes were studied for the target ventilation level under the specific tobacco column and filter tip in order to reduce the variation of filter ventilation. When Nicolas Baskevitch\`s equation on filter ventilation was used to try out Monte Carlo Simulation, at the combination where tipping paper permeability is high and plug wrap permeability is low, even the small change in tipping paper and plug wrap permeability showed high variation of target ventilation level. Also, according to the analysis data of filter ventilation in cigarettes designed at the level of 45% filter ventilation by the combinations with tipping paper and plug wrap, the variation in cigarette filter ventilation was increased as increasing tipping paper permeability and decreasing plug wrap permeability. As the results of this study, the variation of filter ventilation can be reduced by increasing plug wrap permeability/tipping paper permeability ratio in the cigarette design, considering 2-3% of tipping paper permeability variation(%CV) and about 10% of plugwrap permeability variation.

  • PDF

공동주택의 환기시스템별 에너지성능 비교 분석 (A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House)

  • 김길태;전주영;김선동
    • 토지주택연구
    • /
    • 제6권4호
    • /
    • pp.215-220
    • /
    • 2015
  • 본 연구는 공동주택에 적용되고 있는 환기장치를 선정하고 환기장치의 에너지특성 분석과 에너지저감을 목적으로 시뮬레이션 프로그램 (ECO2)을 이용하여 환기장치 별 에너지성능평가를 수행하였으며, 아래와 같이 결과를 도출하였다. 공동주택을 대상으로 환기장치 별 에너지 효율등급평가 기준에 따른 소비량을 수행하고자 하였다. 또한 단지별 에너지소비량과 비교 검토 결과를 통하여 현재 우리나라에서 공동주택에 적용하고 있는 환기장치별 에너지 소비량 실태를 파악하였다. 중부지방의 84type, 한 개동을 대상으로 시뮬레이션한 결과, 자연환기장치의 등급용 1차에너지소요량 값은 $159.9kWh/m^2yr$, 전열교환환기장치 $161kWh/m^2yr$, 바닥환기장치 $179.7kWh/m^2yr$로 계산 되었다. 위 시뮬레이션 결과를 공동주택의 실제 현장자료로 검증하였으며, 환기장치별 에너지소요량에 대한 비율로 비교해본 결과, 전열교환환기방식이 자연환기방식에 비해 -1~6% 적은 값을 보였으며, 바닥배관환기방식이 자연환기방식에 비해 약 10~20% 더 많은 1차에너지소요량이 나타났다. 환기장치의 팬동력과 열회수효율에 따라 에너지소요량의 난방과 환기 값이 변화하며, 향후 기계환기장치의 효율화 및 최적화가 필요하다고 판단된다.

공동주택용 환기장치의 실내공기질 개선효과에 대한 현장실험연구 (Field Studies on the Improvement of Indoor Air Quality by Ventilator in Apartment Houses)

  • 성기철;장현재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.202-211
    • /
    • 2007
  • Ventilation system is being recommended as an effective tool to improve indoor air quality (IAQ) in apartment houses. Recently, in Korea, apartment house suppliers must establish ventilation system in apartment houses in law. In this study, improvement of IAQ by establishing mechanical ventilation system at apartment house was investigated by mockup test. Seven apartment houses were arranged for the test and improvement of IAQ was examined under the various conditions of ventilation rates, ventilator type and duct works. The results of this study show that IAQ in the test houses which were established mechanical ventilation system was improved about from 30% to 40% compared with IAQ in the apartment house which was not established ventilation system. However, there were no apparent concentration differences between the cases of changing ventilation rates, ventilator types and ductworks.

청과물 저장에 관한 연구(제1보) -통기량 조절에 따른 저장실내 기체조성 및 생리화학적 변화에 대하여- (A Study on the Storage of Fresh Fruits and Vegetables (I) -Changes of the Internal Atmosphere in Storage Room and the Biochemical Changes of Apple Fruits by Controlled Ventilation-)

  • 손태화;최종욱;김성달
    • 한국식품과학회지
    • /
    • 제4권1호
    • /
    • pp.13-17
    • /
    • 1972
  • This experiment was conducted to observe the changes of composition of atmosphere in storage room by controlled ventilation under normal and sub-atmospheric conditions, and the biochemical changes in apple texture under these conditions. The results were as follows; 1) By controlled ventilation, concentration of carbon dioxide in storage room was optionally regulated and constantly maintained. 2) Among compositions of internal atmosphere of apple, especially, concentration of ethylene was much decreased at apple stored under sub-atmospheric condition than that stored under normal atmospheric condition. 3) Acidity of apple stored under sub-atmospheric condition was much greater than that of apple stored under normal atmospheric condition. 4) Respiratory quotients of apple, which was stored under normal and sub-atmospheric conditions, were shown to be high. But decarboxylation of added pyruvate was found more active in slices prepared from apple stored under sub-atmospheric condition.

  • PDF

Eucalyptus pellita의 기내(器內) 줄기생장에 미치는 LEDs (Light-emitting diodes) 및 환기처리(換氣處理) 효과 (Effect of Light-emitting Diodes (LEDs) and Ventilation on the in vitro Shoot Growth of Eucalyptus pellita)

  • 김지아;문흥규
    • 한국산림과학회지
    • /
    • 제95권6호
    • /
    • pp.716-722
    • /
    • 2006
  • Eucalyptus pellita 기내줄기를 재료로 광질에 따른 생육 특성을 조사하였다. 전반적으로 줄기의 생장은 광질보다는 환기처리가 더 주요한 요인으로 나타났다. 특히 환기처리 한 청색광(blue LED) 하에서 묘고, 잎수, 절간수 및 액아수가 양호하였고, 잎에 캘러스가 형성되지 않았다. 식물체의 충실정도를 나타내는 건물율 역시 환기처리 하에서 높게 나타났으며, 청색광 하에서 가장 높은 건물율을 나타냈다. 광질별 총엽록소 함량은 형광등과 혼합광 R5B5(50% red LED + 50% blue LED)에서 $24.5{\mu}g/g$$20.1{\mu}g/g$으로 가장 높게 나타났다. 광합성에 관여하는 카로티노이드 함량 역시 적색광(red LED)을 제외한 모든 광질에서 환기 처리 시 양호하게 나타났다. 결론적으로 E. pellita의 기내 줄기생장은 환기처리가 중요하고, 총 카로티노이드 함량을 기준으로 볼 때 혼합광 R5B5에서 건전한 줄기생장이 가능한 것으로 나타났다.

환기 조건에 따른 화재거동 연구 (On the Fire Behavior Due to the Ventilation Condition in the Fire Compartment)

  • 김성찬
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.367-373
    • /
    • 2008
  • A series of fire experiments has been conducted to provide an improved understanding of the fire structure of under-ventilated compartment fires. A comprehensive and quantitative assessment of gaseous species from the fire was made in the upper layer of fire in a 40 % reduced scale ISO 9705 fire compartment. The global equivalence ratio (GER) concept was used to characterize the fire behavior for various fire sizes, fuel types and ventilation conditions. The oxygen concentration in the upper layer reached to zero near the global equivalence ratio of $0.4{\sim}0.6$ while the carbon monoxide concentration increases with increasing the global equivalence ratio. Classification parameters of ISO19706 were also compared with the reduced scale experimental data for under ventilation fire.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • 유통과학연구
    • /
    • 제17권7호
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

A Study on the Ventilation Method for a Factory with a Sealed Structure

  • Kim, Yeong-Sik;Yi, Chung-Seob;Lee, Dae-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.159-165
    • /
    • 2014
  • On this work, the importance of industrial ventilation was investigated and examined the theoretical point and problems about general ventilation of factory exposed on high temperature during summer. As a case study, the ventilation planning of the printed circuit board (PCB) etching process for an electronic company was carried out and each of those characteristics were compared by installing actual ventilation systems and measuring the changing state of the working environment in accordance with ventilation method during summer. The purpose of the study is to present an efficient ventilation method for a factory with a closed structure under high temperature environment. In summary, for a factory with a sealed structure such as the target PCB manufacturing factory in this study, the forced supply and exhaust method was the most appropriate ventilation method for maintaining a low.

불활성가스 미분무소화설비의 개발 -화재시험실의 급기에 관한 수치연구- (Development of an Inert Gas Water Mist System -A Numerical Study on Ventilation of the Fire Test Room-)

  • 박외철;정이규
    • 한국가스학회지
    • /
    • 제12권1호
    • /
    • pp.25-30
    • /
    • 2008
  • 불활성가스 미분무소화설비의 실험용으로 제작된 $2.5m{\times}2.0m{\times}2.5m$ 크기의 화재시험실에 급기부족 여부를 확인하기 위해, 화재시험실 내 프로판가스 풀(pool) 화재에 대한 수치연구를 수행하였다. 결과의 일관성을 확인하기 위해 설계 화재규모인 60 kW와 그 2배인 120 kW에 대하여 창문의 개폐에 따른 온도 및 일산화탄소 농도의 변화를 조사하였다. 두 화재규모에서 모두 창문의 개폐가 온도 및 CO농도의 변화에 미치는 영향이 작음을 확인하였고, 따라서 급기부족의 발생이 없음을 알 수 있었다.

  • PDF

스포츠웨어의 슬릿 벤틸레이션 시스템이 인체 생리반응에 미치는 효과 (Effect of Slit Ventilation System in Sportswear on Physiological Responses)

  • 연수민;김희은
    • 한국의류산업학회지
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2005
  • The purpose of this study was to investigate the effects of silt ventilation system on physiological responses. We measured rectal temperature, local skin temperature, clothing microclimate, blood pressure, heart rate, energy metabolism, body weight loss and subjective sensation during 70 minute, 50 min exercise period and 20 min rest period. The five women subjects randomly wore sportswear without slit ventilation system(NS sportswear) and sportswear with slit ventilation system(S sportswear) under the environmental condition of $25^{\circ}C$, 50%RH. The results of this study are as follows; Rectal temperature, mean skin temperature, clothing microclimate, blood pressure, heart rate, energy metabolism and body weight loss were significantly lower level in 'S sportswear'. In 'S sportswear', subjects replied less hot, less uncomfortable and less wet. Slit ventilation system can be used for bellow effect which is meaningful device of convection during exercise. We could find out that 'S sportswear' has advantage in physiological function.