• Title/Summary/Keyword: Uncertainty measurement

Search Result 930, Processing Time 0.047 seconds

Measurement of Rotor Blade Deformation and Motions using Stereo Pattern Recognition Method (SPR 기법을 이용한 회전 블레이드의 변형 및 모션 측정)

  • Park, Jae-Won;Kim, Hong-Il;Han, Jae-Hung;Kim, Do-Hyung;Song, Keun-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.5
    • /
    • pp.442-450
    • /
    • 2011
  • A measurement system using stereo pattern recognition (SPR) method was configured to measure the rotor blade deformations and motions. An SPR-based measurement system was prepared using six stereo cameras. Through a series of experiments to evaluate the system measurement uncertainty, it was verified that the SPR system had less than 0.2mm standard uncertainty. The combined standard uncertainties for the lead-lag, flapping, and pitching motions were estimated as 0.296mm, 0.209mm, and $0.238^{\circ}$, respectively. The SPR system was installed at a general small-scaled rotor test system at Korea Aerospace Research Institute. The blade motions and elastic deformation were successfully measured under the conditions with rotating speeds of 360rpm or 589rpm, and collective pitch angles of $0^{\circ}$, $4^{\circ}$, or $6^{\circ}$. The advantages of the SPR system was analyzed in comparison with the measurement system used in Higher Harmonic Control Aeroacoustic Rotor Test -II.

Precise EPD Measurement of Single Crystal Sapphire Wafer

  • Lee, Yumin;Kim, Youngheon;Kim, Chang Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.223.1-223.1
    • /
    • 2013
  • Since sapphire single crystal is one of the materials that have excellent mechanical and optical properties, the single crystal is widely used in various fields, and the demand for the use of substrate of LED devices is increasing rapidly. However, crystal defects such as dislocations and stacking faults worsen the properties of the single crystal intensely. When sapphire wafer of single crystal is used as LED substrate, especially, crystal defects have a strong influence on the characteristics of a film deposited on the wafer. In such a case quantitative assessment of the defects is essential, and the evaluation technique is now becoming one of the most important factors in commercialization of sapphire wafer. Wet etching is comparatively easy and accurate method to estimate dislocation density of single crystal because etching reaction primarily takes place where dislocations reached crystal surface which are chemically weak points, and produces etch pit. In the present study, the formation behavior of etch pits and etching time dependence were studied systematically. Etch pit density(EPD) analysis using optical microscope was also conducted and measurement uncertainty of EPD was studied to confirm the reliability of the results. EPDs and measurement uncertainties for 4 inch sapphire wafers were analyzed in terms of 5 and 21 points EPD readings. EPDs and measurement uncertainties in terms of 5 points readings for 4 inch wafers were compared by 2 organizations. We found that the average EPD value in terms of 5 points readings for a 4 inch sapphire wafer may represent the EPD value of the wafer.

  • PDF

Attitude Estimation of Unmanned Vehicles Using Unscented Kalman Filter (무향 칼만 필터를 이용한 무인 운송체의 자세 추정)

  • Song, Gyeong-Sub;Ko, Nak-Yong;Choi, Hyun-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.265-274
    • /
    • 2019
  • The paper describes an application of unscented Kalman filter(UKF) for attitude estimation of an unmanned vehicle(UV), which is equipped with a low-cost attitude heading reference system (AHRS). The roll, pitch and yaw required at the correction stage of the UKF are calculated from the measurements of acceleration and geomagnetic field. The roll and pitch are attributed to the measurement of acceleration, while yaw is calculated from the geomagnetic field measurement. Since the measurement of geomagnetic field is vulnerable to distortion by hard-iron and soft-iron effects, the calculated yaw has more uncertainty than the calculated roll and pitch. To reduce the uncertainty of geomagnetic field measurement, the proposed method estimates bias in the geomagnetic field measurement and compensates for the bias for more accurate calculation of yaw. The proposed method is verified through navigation experiments of a UV in a test pool. The results show that the proposed method yields more accurate attitude estimation; thus, it results more accurate location estimation.

Development of Measurement Technology for Uptake and Diffusivity of Hydrogen gas in Rubber Materials using Volumetric Analysis (부피 분석법을 이용한 고무 소재의 수소 기체 장입량 및 확산도 측정 기술 개발)

  • LEE, JI HUN;JUNG, JAE KAP;BAEK, UN BONG;CHUNG, KI SOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.67-76
    • /
    • 2022
  • We developed a technology that can measure the hydrogen uptake and diffusivity of rubber materials by using the volumetric analysis method and diffusivity analysis program through the measurement of the water level in the graduated cylinder. In this method, hydrogen gas is charged at a certain pressure for a certain period of time for a rubber material exposed to a high-pressure hydrogen gas environment, and then the pressure is reduced to measure the change in the water level in the graduated cylinder in real time, and based on the measured value, it is a technology that can evaluate hydrogen uptake and diffusivity using diffusivity analysis program. Using this method, the hydrogen uptake and diffusivity of the NBR material were measured with respect to the change in the type and weight ratio of the filler used to improve the physical properties of the rubber material. In addition, uncertainty analysis was performed on the diffusivity measurement method.

Evaluating LIMU System Quality with Interval Evidence and Input Uncertainty

  • Xiangyi Zhou;Zhijie Zhou;Xiaoxia Han;Zhichao Ming;Yanshan Bian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.2945-2965
    • /
    • 2023
  • The laser inertial measurement unit is a precision device widely used in rocket navigation system and other equipment, and its quality is directly related to navigation accuracy. In the quality evaluation of laser inertial measurement unit, there is inevitably uncertainty in the index input information. First, the input numerical information is in interval form. Second, the index input grade and the quality evaluation result grade are given according to different national standards. So, it is a key step to transform the interval information input by the index into the data form consistent with the evaluation result grade. In the case of uncertain input, this paper puts forward a method based on probability distribution to solve the problem of asymmetry between the reference grade given by the index and the evaluation result grade when evaluating the quality of laser inertial measurement unit. By mapping the numerical relationship between the designated reference level and the evaluation reference level of the index information under different distributions, the index evidence symmetrical with the evaluation reference level is given. After the uncertain input information is transformed into evidence of interval degree distribution by this method, the information fusion of interval degree distribution evidence is carried out by interval evidential reasoning algorithm, and the evaluation result is obtained by projection covariance matrix adaptive evolution strategy optimization. Taking a five-meter redundant laser inertial measurement unit as an example, the applicability and effectiveness of this method are verified.

Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS (LC-MS/MS를 이용한 소변 중 크레아티닌 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kwon, Woon-Yong;Suh, Sung-Ill;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.83-90
    • /
    • 2012
  • The objective of the study was to estimate the measurement uncertainty associated with determination of creatinine (Cr) in urine samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Centrifuged urine samples (10 ${\mu}L$) were diluted with 390 ${\mu}L$ of distilled water. To 20 ${\mu}L$ aliquots of diluted urine samples, 30 ${\mu}L$ of internal standard solution (Cr-$d_3$, 5 ${\mu}g/mL$) and 10 ${\mu}L$ of acetonitrile were added and filtered. The samples (1 ${\mu}L$) were introduced into LC-MS/MS with no further pretreatment. Cr was separated on a multi-mode ODS column (Scherzo SM-C18, 75 ${\times}$ 2.0 mm I.D., 3 ${\mu}m$) and quantified by LC-MS/MS operating in MRM mode (Cr, m/z 114.0${\rightarrow}$ 86.0; Cr-$d_3$, m/z 117.0${\rightarrow}$ 89.1). The four factors that contribute uncertainty to the final result were extracted and evaluated. The principal factors of contribution to combined standard uncertainty were sample dilution, calibration curve and repeatability, while the preparation of standard solution was only a minor factor. Relative extended uncertainty of the measured concentration was 14.2% in a real urine sample.

Validation and Uncertainty Evaluation of an Optimized Analytical Method Using HPLC Applied to Canthaxanthin, a Food Colorant (식품 색소 Canthaxanthin의 HPLC 최적 분석법 확인 및 타당성과 측정불확도 평가)

  • Suh, Hee-Jae;Kim, Kyung-Su;Hong, Mi-Na;Lee, Chan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.3
    • /
    • pp.342-351
    • /
    • 2016
  • This study was carried out to develop an optimized analytical method using high-performance liquid chromatography (HPLC) applied to canthaxanthin, which is not yet designated as a food colorant in Korea, as well as to perform validation and uncertainty evaluation of this method. Official methods of AOAC, UK, and Japan with HPLC-UV detection were evaluated for the analysis of canthaxanthin by comparison of linearity, resolution, selectivity, limit of detection (LOD), limit of quantitation (LOQ), accuracy, precision, recovery, inter-laboratory tests, and uncertainty measurement. The calibration curves showed high linearity with an $R_2$ value of over 0.999 for canthaxanthin standard solutions in all three official methods. The official method of Japan exhibited the best results in terms of resolution and selectivity, including the lowest LOD and LOQ. The average coefficients of variation were calculated as less than five of three institutes with a precision value less than 1, accuracy near 100%, and recovery ratio between $100{\pm}10%$. The expanded uncertainty for canthaxanthin was estimated to be $39.5{\pm}5.29mg/kg$ (95% confidence level, k=2), and the uncertainty of measurement was 13.4%. In this study, official methods of canthaxanthin were compared and the validities verified. The results will be further applied to establish an authorized analytical method for canthaxanthin in Korea.

Application of Rainfall Runoff Model with Rainfall Uncertainty (강우자료의 불확실성을 고려한 강우 유출 모형의 적용)

  • Lee, Hyo-Sang;Jeon, Min-Woo;Balin, Daniela;Rode, Michael
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.10
    • /
    • pp.773-783
    • /
    • 2009
  • The effects of rainfall input uncertainty on predictions of stream flow are studied based extended GLUE (Generalized Likelihood Uncertainty Estimation) approach. The uncertainty in the rainfall data is implemented by systematic/non-systematic rainfall measurement analysis in Weida catchment, Germany. PDM (Probability Distribution Model) rainfall runoff model is selected for hydrological representation of the catchment. Using general correction procedure and DUE(Data Uncertainty Engine), feasible rainfall time series are generated. These series are applied to PDM in MC(Monte Carlo) and GLUE method; Posterior distributions of the model parameters are examined and behavioural model parameters are selected for simplified GLUE prediction of stream flow. All predictions are combined to develop ensemble prediction and 90 percentile of ensemble prediction, which are used to show the effects of uncertainty sources of input data and model parameters. The results show acceptable performances in all flow regime, except underestimation of the peak flows. These results are not definite proof of the effects of rainfall uncertainty on parameter estimation; however, extended GLUE approach in this study is a potential method which can include major uncertainty in the rainfall-runoff modelling.

Volumetric Error Measurement and Calibration of Coordinate Measuring Machines Using a Ball-bar Artifact (Ball-Bar Artifact를 이용한 CMM의 공간 오차 측정 및 분석)

  • 구상서;이응석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.143-148
    • /
    • 2001
  • Volumetric error measurement and calibration of a coordinate measuring machine are studied by using a Ball-Bar artifact. Examples of the Ball-Bar design are shown using inbar materials and precision steel balls. Also, for the uncertainty error using the Ball-Bar is discussed. Method of Ball-Bar artifact and the analysis of the error vectors are proposed. Using the Ball-Bar data, we studied the method of volumetric errors ana]ysis of a coordinate measuring machine.

  • PDF