• 제목/요약/키워드: Uncertainty measurement

검색결과 936건 처리시간 0.041초

Robust Wavelet Kalman Filter

  • Lee, Taehoon;Park, Jinbae;Taesung Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.39.3-39
    • /
    • 2001
  • Since Kalman filter and wavelet transform techniques are both suitable for a nonstationary process, wavelet-Kalman filter was proposed and applied to various industrial fields. However, the wavelet-Kalman filter subjected to model uncertainty with nonstationary process has not been considered. Thus, the robust wavelet-Kalman filter method is proposed in this paper. The proposed method can prevent the degradation of filter performance when parameter uncertainty exists in both the state and measurement matrices and preserve the merits of the standard Kalman filter in the sense that it produces optimal estimates. A simple example shows that the proposed approach outperforms the standard Kalman filter and the nominal wavelet-Kalman filter.

  • PDF

비만관 유량계 교정 시스템 구축에 관한 연구 (Study on the Calibration System of Flow Meters in Partly Filled Pipes)

  • 유성호;이동락;이민수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.141-146
    • /
    • 2005
  • Flow meters in partly filled pipes are set up and run in Korea now days, but there are no standard calibration procedures for the flow meters in accordance with ISO/IEC 17025, the standard calibration procedure based on the standard calibration procedures for flow meter in closed conduits and the technical notes of flow meter's makers is developed. the measurement uncertainty of the calibration for the flow meter in partly filled pipes is evaluated.

  • PDF

실온 저항브리지를 이용한 전기저항 측정의 국가표준 기술 (National Measurement Standard of Electrical Resistance using a Room Temperature Resistance Bridge)

  • 유광민;박영태;강전홍;김한준;임국형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.669-672
    • /
    • 2002
  • Establishment of the Quantum Hall Resistance(QHR) Standard as national resistance standard using a room temperature DCC resistance bridge is described. A simple method are used to obtain the current dependence and error of 10: 1 ratio of the bridge instead of the method using a cryogenic resistance bridge. Measurement uncertainty of the system is estimated as $0.14{\times}10^{-6}$ and it is confirmed that the QHR standard is agreed well with the QHR of other NMIs using the cryogenic resistance bridge within the uncertainty, More improvement about performance of the QHR device and 10: 1 ratio accuracy is still under progress.

  • PDF

다중 UAV에서 측정된 거리차 정보를 이용한 선형 강인 표적추적 필터 설계 (Linear Robust Target Tracking Filter Using the Range Differences Measured By Formation Flying Multiple UAVs)

  • 이혜경;한슬기;나원상
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.284-290
    • /
    • 2012
  • This paper addresses a new passive target tracking problem using the range differences measured by cooperative UAVs. In order to solve the range difference based passive target tracking problem within the framework of linear robust state estimation, the uncertain linear measurement model which contains the stochastic parameter uncertainty is derived by using the noisy range difference measurements. To cope with the performance degradation due to the stochastic parameter uncertainty, the recently developed non-conservative robust Kalman filtering technique [1] is applied. For the cruciform formation flying UAVs, the relationship between the target tracking performance and the measurement errors is quantitatively analyzed. The proposed filter has practical advantages over the classical nonlinear filters because, for its recursive linear structure, it can provide satisfactory convergence properties and is suitable for real-time multiple UAVs applications. Through the simulations, the usefulness of the proposed method is demonstrated.

500 kV 개폐충격전압시스템의 비교시험 (Intercomparison Tests of National Standard Measuring System for Switching Impulse Voltage rated 500 kV)

  • 김익수;김민규;정주영;문인욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.261-263
    • /
    • 2003
  • This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with CSIRO of Australia. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.

  • PDF

질량측정에 의한 우량계 표준교정시스템 개발 (Development of Standard Calibration System for the Rain Gauges by Weighting Method)

  • 신강욱;홍성택
    • 제어로봇시스템학회논문지
    • /
    • 제12권8호
    • /
    • pp.818-823
    • /
    • 2006
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the uncertainty for the rainfall intensity and obtained useful result through the proposed calibration method.

수직형 선반의 평면 오차 민감도 분석 및 신뢰도 평가 (Sensitivity Analysis and Confidence Evaluation for Planar Errors of a Vertical Turning Center)

  • 여규환;양승환
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.67-75
    • /
    • 1998
  • Geometric and thermal errors are key contributors to the errors of a computer numerically controlled turning center. A planar error synthesis model is obtained by synthesizing 11 geometric and thermal error components of a turning center with homogeneous coordinate transformation method. This paper shows the sensitivity analysis on the temperature change, the confidence evaluation on the uncertainty Of measurement systems, and the error contribution analysis from the planar error synthesis model. Planar error in the z direction was very sensitive to the temperature change. and planar errors in the x and z directions were not affected by the uncertainty of measurement systems. The error contribution analysis ,which is applicable to designing a new turning center, was helpful to find the large error components which affect planar errors of the turning center.

  • PDF

Application of particle filtering for prognostics with measurement uncertainty in nuclear power plants

  • Kim, Gibeom;Kim, Hyeonmin;Zio, Enrico;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1314-1323
    • /
    • 2018
  • For nuclear power plants (NPPs) to have long lifetimes, ageing is a major issue. Currently, ageing management for NPP systems is based on correlations built from generic experimental data. However, each system has its own characteristics, operational history, and environment. To account for this, it is possible to resort to prognostics that predicts the future state and time to failure (TTF) of the target system by updating the generic correlation with specific information of the target system. In this paper, we present an application of particle filtering for the prediction of degradation in steam generator tubes. With a case study, we also show how the prediction results vary depending on the uncertainty of the measurement data.

인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정 (Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method)

  • 전장영;곽병만;안장혁;공운영
    • 한국식품과학회지
    • /
    • 제37권3호
    • /
    • pp.352-359
    • /
    • 2005
  • 인도페놀 적정법을 이용하여 성장기용 조제식 중 비타민 C 함량을 측정하는 과정 중의 측정불확도를 추정하기 위하여 분석결과에 영향을 주는 인자들을 파악하고 각각의 불확도를 산출하였으며, 불확도의 계산은 GUM(Guide to the expression of Uncertainty in Measurement)과 Draft EURACHEM CITAC Guide에 근거한 수학적 계산 및 통계처리 방법에 의해 처리하였다. 인도페놀 적정법에 의한 비타민 C 함량 측정시 measurand상의 uncertainty source로서 표준품 순도, 표준품 무게, 표준품 최종전량, 적정에 사용된 표준용액 부피, 인도페놀 용액에 의한 표준용액 적정, 시료의 무게, 시료의 최종전량, 적정에 사용된 시험용액, 인도페놀 용액에 의한 시험용액 적정 등이 작용하였으며, uncertainty source에 영향을 주는 세부인자인 uncertainty parameter로서는 저울의 안정성, 분해능, 재현성, 1 mL 피펫, 5 mL마이크로피펫, 100 mL 메스플라스크의 눈금읽기, 내부교정 등이 작용하였다. 소급성 유지를 위해 비타민 C 함량과 측정불확도가 보장된 인증표준물질인 Infant Formula SRM 1846을 사용하여 비타민 C 함량을 측정한 결과값은 $108.4{\pm}1.7mg/100g$로 인증값인 비타민 C 함량 $114.6{\pm}6.6mg/100g$의 범위내로 측정되었으며, CRM에서 보장된 균일성과 실험오차를 고려하면 유사한 결과가 산출되었음을 알 수 있다(p<0.05). 이와 같은 소급성 검증 후 시중에 유통 중인 성장기용조제식의 비타민 C 함량을 분석하기 위하여 시료량을 달리 하여 측정불확도를 계산한 결과, 본 연구에서는 시료를 최소한 5g은 취해야 결과값 및 측정불확도가 $56.7{\pm}2.44mg/100g$으로서 5%이하로 측정불확도를 유 지할 수 있었다. 이와 같이 측정불확도를 고려하여 서로 상이한 분석방법간의 신뢰성을 비교 검증하여야 하며, 획일적으로 단순히 적정법과 HPLC법을 비교해서는 다소 무리가 있을 것으로 판단된다. 본 연구에서와 같이 측정불확도를 고려하여 분석에 영향을 줄 수 있는 요인들을 최소화한다면 HPLC와 같은 고가의 정밀분석기기를 구비하지 못한 실험실에서도 인도페놀 적정법에 의한 비타민 C 분석방법을 이용하여 신뢰성있는 측정결과를 얻을 수 있을 것으로 사료된다.

AAS 및 ICP-AES에 의한 조제분유 중 칼슘 함량 분석의 측정불확도 산정 (Quantifying Uncertainty of Calcium Determination in Infant Formula by AAS and ICP-AES)

  • 전장영;곽병만;안장혁;공운영
    • 한국식품과학회지
    • /
    • 제36권5호
    • /
    • pp.701-710
    • /
    • 2004
  • 건식분해에 의한 AAS법과 습식분해에 의한 ICP법을 이용하여 조제분유 중 칼슘 함량을 측정하는 과정중의 측정불확도를 비교산정하기 위하여 분석결과에 영향을 주는 불확도 인자를 파악하고 각각의 불확도를 계산하였다. 계산은 GUM(Guide to the expression of Uncertainty in Measurement)과 Draft EURACHEMCITAC Guide에 근거한 수학적 계산 및 통계처리 방법에 의해 처리하였다. AAS에 의한 칼슘 측정시 uncertainty source로서 시료의 무게, 시료의 최종전량, 시료의 희석 그리고 기기에 의한 측정결과값 등이 작용하였다. Uncertainty source의 개별구성요소인 uncertainty component는 저울의 안정성, 분해능, 재현성, 표준액의 순도, 분자량, 농도, 표준액 희석 및 시료의 희석, 검정선, 회수율 그리고 분석기기의 정밀성, 재현성 및 안정성 등이 작용하였으며 A type 또는 B type으로 불확도를 산정하였다. ICP에 의한 칼슘 측정시 uncertainty souce와 component는 시료의 희석부분을 제외하고 AAS와 동일하게 작용하였다. 칼슘함량과 측정불확도가 보장된 인증표준물질인 Infant Formula SRM 1846을 사용하여 칼슘함량을 측정한 결과 AAS법에 의한 결과값과 ICP법에 의한 결과값은 각각 $359.52{\pm}23.61\;mg/100g$, $354.75{\pm}16.16mg/100g$으로 측정되었다. 2가지 방법 모두 인증 값인 칼슘함량 $367{\pm}20mg/100g$의 범위내로 측정되었으며, CRM에서 보장된 균일성과 실험오차를 고려하면 유사한 결과가 산출되었음을 알 수 있다(p<0.05). 측정불확도를 시험담당자가 시험수행시마다 파악하고 계산하기란 시간적, 인력적 제약과 업무효율적 측면에서 현실적으로 어려운 점이 많다. 그러나, 본 연구에서와 같이 시험과정 중의 분석오차 발생인자를 파악하고 최종 시험결과에 미치는 영향정도를 산출하여 그 인자들을 최소화하여야 할 것으로 사료된다. 즉, 측정불확도는 불확도인자 설정과 계산에 있어서 다양한 방법이 제시될 수 있으므로 수치화된 결과값 그 자체보다는 표준시약의 소급성 유지, 시험기구의 교정 관리, 시험실 환경 관리, 분석기기의 최적상태 유지 및 개인숙련도 향상 등과 같은 노력을 통해 시험결과의 품질을 최상으로 유지하는 척도로 활용되어야 할 것으로 사료된다.