• Title/Summary/Keyword: Unbalanced condition

Search Result 172, Processing Time 0.027 seconds

Analysis of Parallel-Input Series-Output(PISO) Boost Converter With Output Voltage Balancing Characteristic (병렬입력/직렬출력(PISO) 부스트 컨버터의 출력 전압 밸런싱 특성 해석)

  • Nam, Hyun-Taek;Cha, Honnyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.40-46
    • /
    • 2018
  • In this study, the output voltage balancing characteristics of parallel-input series-output (PISO) boost converter is analyzed. The PISO boost converter is derived by combining two basic boost converters. In comparison with the conventional three-level boost converter, the PISO boost converter can balance the output voltages under an unbalanced load condition without requiring additional circuit components and control strategy. A 2 kW prototype converter is built and tested to verify the output voltage balancing characteristics of the PISO boost converter.

A study on neutral-point voltage balance with harmonic component injection for single phase three-level NPC converter (고조파 주입을 통한 단상 3레벨 NPC 컨버터 중성점 전압 밸런싱 연구)

  • Kang, Kyoung Pil;Kim, Ho-Sung;Cho, Jintae;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.316-317
    • /
    • 2018
  • This paper propse the DC link capacitor voltage balancing control for three level neutral point clamped converter with harmonic component injection method. The injcetion voltage consists of harmonic component and DC link capacitor voltage difference. Theoretical analysis is provided to balance the DC link voltage, and it shows that harmonic component compensates the unbalanced condition between the capacitors. Both simulations and experiments are carried out to show that the voltage unbalance have been decreased by the proposed method.

  • PDF

A Smooth transfer control strategy under unbalanced load condition (불평형 부하 조건을 고려한 무순단 절체 알고리즘)

  • Kim, Ki-Ryong;Oh, Chang-Yeol;Kwon, Min-Ho;Lee, Jong-Pil;Kim, Tae-Jin;Kim, Hee-Je
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.444-445
    • /
    • 2018
  • 신 재생에너지원을 바탕으로 하는 분산 발전이 증가함에 따라 이에 사용되는 PCS 또한 계통연계 및 독립 모드 운전을 해야 한다. PCS는 두 운전 모드 전환 시 발생하는 과도 상태를 최소화하기 위해 무순단 절체 기능이 필요하다. 이 기능은 평형 부하 뿐만 아니라 불평형 부하 상황에서도 이루어 져야 한다. 따라서, 본 논문에서는 불평형 부하 조건에서 무순단 절체 기능이 동작하는 것을 보이며, 시뮬레이션을 통해 제어 알고리즘의 타당성을 검증한다.

  • PDF

Characteristic Analysis of Capacitor-Run Single Phase Inuction Motor by Equivalent Circuit Coupled with Finite Element Method (유한요소법과 등가회로 해석의 결합에 의한 콘덴서 구동형 단상유도전동기의 특성해석)

  • Nam, Hyuk;Ha, Kyung-Ho;Kang, Gyu-Hong;Hong, Jung-Pyo;Jeong, Seung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.837-839
    • /
    • 2000
  • Capacitor-run single induction motors have the unbalanced elliptic rotating magnetic field so that it is difficult to analyze the characteristic and calculate the accurate slot leakage reactance of the rotor with the closed slot by using the lumped parameter. In this paper, the characteristic is analyzed by the symmetrical coordinate method in terms of the lumped parameter coupled with the numerical analysis. The secondary parameters are calculated by the one slot pitch boundary condition applying to Finite Element Method (FEM). The analysis results are compared with experimental ones.

  • PDF

Neutral Line Current Compensation Method of Active Power Filter (전력용 능동 필터의 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.504-506
    • /
    • 2005
  • This paper proposes a new neutral current reduction method using PQR instantaneous power theory on the active power filter, unbalanced nonlinear load condition in three-phase four-wire systems. For reduction of neutral line current, the single phase active power filter is used and its performance is same with the three-phase four-wire active power filter. For fully-digital implementation, ramp comparison PWM method was adopted. Simulation results verify good performance of the proposed current control strategy on the shunt APFs.

  • PDF

Three control strategies based on a-b-c frame for AC-DC converter (a-b-c 프레임에 근거한 AC-DC 변환기용 세가지 제어전략)

  • Lee, Dong-Su;Kim, Ji-Woong;Jeon, Seong-Jeub;Huh, Man-Tak
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.283-285
    • /
    • 2005
  • Three control strategies that can be applied to a three-phase AC-DC converter under unbalanced input voltage condition are discussed. Analytic solutions are given on the a-b-c frame, and are very simple, direct and Intuitive. All of the strategies guarantee sinusoidal input currents. All the control functions, including decoupled current control and PWM, are implemented on the a-b-c frame. Accordingly, the controller is very simple and robust. The proposal is verified by simulation and experiments on a prototype operating at 15 kHz

  • PDF

Current Reference Calculation for Distribution Static Compensator using Phase Shift (위상변이를 이용한 배전용 정지형 보상기의 전류 지령 계산)

  • Hong, Sung-Min;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 2012
  • This paper proposes a calculation of compensation current using phase shift to eliminate ripple components of instantaneous active power under unbalanced or non-linear loads condition. The proposed phase shift method instead of existing method(LPF; Low Pass Filter) to remove ripple components and this proposed method improves performances of transient and steady state response. To compare proposed method with existing method, experiments have been done for calculating an average active power at load side. Their results show that transient response and steady state response of proposed method is improved.

New Control Seheme for AC-DC-AC Converters without DC Link Electrolytic Capacitor (직류링크 전해커패시터 없는 AC-DC-AC 컨버터 재어에 관한 연구)

  • 김준석;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.397-408
    • /
    • 1994
  • In this paper, a novel concept for a static three-phase to three-phase power converter for an AC drive with a unity power factor and reduced harmonics on the utility line is presented. The power circuit consists of two back-to-back connected six-pulse bridges having only a $\mu$F ceramic capacitor in the DC link. By controlling the active kpower balance between two bridges, the DC link voltage can be maintained within 20V deviation from the nominal value with the small ceramic capacitors regardless of the load variation even in the unbalanced source condition.

  • PDF

Effect of Airgap Length Difference on the Characteristics of the Double-Sided Linear Pulse Motor (공극 길이 차이가 양측식 리니어 펄스 모터의 특성에 미치는 영향)

  • 이동주;이은웅;김성현;손홍관;김성종
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Generally, thrust force of double-sided LPM is more powerful than that of single-sided LPM. Also, double-sided LMP can be effectively applied to the high-precision position system with its simple control scheme. However, An equality between two airgap lengths Is a necessary condition for its high performance. If a little difference between two airgaps is existed, unbalanced normal force and undesirable vibration will be generated. Additionally, even though two airgap lengths are absolutely same, undesirable vibration can be generated because the direction of instantaneous normal force on mover is changed according to excitation methods. An effect of inequality of two airgap lengths is presented in this paper. Distribution of airgap permeance vs. relative displacement is analyzed by two dimensional finite element method. Excitation From this results, current waveforms to reduce the undesirable vibration is proposed.

A New Average Power Algorithm for Active Power Filters Under Unbalanced Source Condition (3상 불평형 전원 조건하의 능동전력필터를 위한 새로운 평균전력 알고리즘)

  • Jung Kwang-Sik;Jung Young-Gook;Kim Young-Cheol;Lim Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.97-100
    • /
    • 2001
  • 본 연구에서는 3상이 불평형된 전원 조건하에서 비선형 부하전류를 유효성분, 기본파 무효성분 그리고 왜 형성분으로 분해한 후, 능동전력필터를 제어할 수 있는 새로운 평균전력 알고리즘을 제시하였다. 제안된 방법의 타당성을 입증하기 위해, $15\%$ 불평형된 3상 전원 전압하에서 실험을 수행하였으며, 종전의 평균전력 알고리즘에 비하여 새로운 평균전력 알고리즘의 유용성을 입증할 수 있었다.

  • PDF