• 제목/요약/키워드: Unbalanced condition

검색결과 172건 처리시간 0.023초

불평형 고장시의 초전도 케이블의 응동 특성 (Dynamic Characteristic of the Superconducting Cable in unbalanced Faults)

  • 이근준;이종배;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.37-39
    • /
    • 2007
  • In the faults of power line, single line ground and line-to-line fault make power system to unbalanced. These fault currents make unbalanced power system. This paper suggests the simulation results of dynamic characteristic of HTS cable system under unbalanced faults condition using EMTDC, Quench phenomenon and current limiting effects are observed. However, quench on the HTS is destroy cable system, coordination with SFCL has to be considered.

  • PDF

마산시내 일부 국민학교 아동의 단백질 급원식품에 대한 편식과 가정환경, 학력 및 인성과의 관계 연구 (The Study on the Relationship Between the Unbalanced diets of Protein-rich Food and General Circumstances, Growth, School Performance & Character among Elementary School Children of Masan)

  • 정효숙
    • 대한가정학회지
    • /
    • 제27권3호
    • /
    • pp.39-51
    • /
    • 1989
  • In this study, 419 students of the 6th grade in three schools in Masan were surveyed. The students having less than 24 items among 48 protein-rich foods easily obtained were considered as unbalanced-diet students. Their general circumstances, character, status of growth and development and school performance were compared with those of balanced-diet students. The results were following. 1. The actual condition of unbalanced diets of protein-rich food 1) Female showed high degree of unbalanced diet in meat food while male in shell-food. Both sexes liked processed food stuffs such as ham, sausage and boiled fish paste but not salted. Both of them disliked beans. 2) The reason for unbalanced diet, they answered, was bad taste and smell of some foods. The reason, their mothers amswered, was they fed their children some particualr foods. 3) The attitudes of the mothers against unbalanced diets were coaxing their children to eat some foods for they are good for health or forcing their children to eat some foods. The most effective method on the children was coaxing and the next was changing cuisines. 2. The general circumstances of the students. 1) 168 students (male: 85, female:83) among 419 students who were studied were unbalanced-diet students and the extent of unbalanced diet was similar in both sexes. 2) The rate of unbalanced-diet students was higher among the students who were the first child in the family, had a small family or were fed milk or mixed milk. 3) The school career of unbalanced-diet student's mothers was higher and the rate of unbalanced-diet students was higher among the students who have rich families or career mothers. 3. The status of physical condition 1) The height and weight of unbalanced-diet students were lower than those of the standard of Korean children. The status of balanced-diet students were better than that of the standard. 4. Degree of school performance 1) The school records of unbalanced-diet students was 81.4 points in average, which was 1.3 points lower than the average of city students and that of balanced-diet students was 2.8 points higher than average. There was a significant gap between the two groups. 5. The relation between unbalanced diet and character 1) Compared balanced-diet students, unbalanced-diet students showed high degree of nervousness and coldheartedness and low degree of self-reliance and self-possession. There was a significant gap between the two groups and it showed that unbalanced diets affected the formation of character.

  • PDF

초전도 전력케이블의 전류 불평형에 관한 연구 (A Study on the Unbalanced Current Distribution of HTS Power Cable)

  • 김재호;박충화
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.

Application of Multiple Parks Vector Approach for Detection of Multiple Faults in Induction Motors

  • Vilhekar, Tushar G.;Ballal, Makarand S.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.972-982
    • /
    • 2017
  • The Park's vector of stator current is a popular technique for the detection of induction motor faults. While the detection of the faulty condition using the Park's vector technique is easy, the classification of different types of faults is intricate. This problem is overcome by the Multiple Park's Vector (MPV) approach proposed in this paper. In this technique, the characteristic fault frequency component (CFFC) of stator winding faults, rotor winding faults, unbalanced voltage and bearing faults are extracted from three phase stator currents. Due to constructional asymmetry, under the healthy condition these characteristic fault frequency components are unbalanced. In order to balanced them, a correction factor is added to the characteristic fault frequency components of three phase stator currents. Therefore, the Park's vector pattern under the healthy condition is circular in shape. This pattern is considered as a reference pattern under the healthy condition. According to the fault condition, the amplitude and phase of characteristic faults frequency components changes. Thus, the pattern of the Park's vector changes. By monitoring the variation in multiple Park's vector patterns, the type of fault and its severity level is identified. In the proposed technique, the diagnosis of faults is immune to the effects of unbalanced voltage and multiple faults. This technique is verified on a 7.5 hp three phase wound rotor induction motor (WRIM). The experimental analysis is verified by simulation results.

불평형 전압 조건에 강인한 모듈형 멀티레벨 컨버터의 순환전류 억제기법 (Robust Circulating Current Control in MMC Under the Unbalanced Voltage Condition)

  • 문지우;박정우;강대욱;김장목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.996-997
    • /
    • 2015
  • This paper proposes parameter design principle of the sub-module capacitance, Arm inductance and a control method to reduced the circulating currents in modular multilevel converter(MMC) under unbalanced voltage conditions. Under balanced voltage conditions, only negative-sequence circulating currents exist. Consequently, the conventional method has considered only negative-sequence circulating currents in MMC. However, under unbalanced voltage conditions, there are positive-sequence, zero-sequence and negative-sequence circulating currents in MMC. Thus, under unbalanced voltage conditions, a control method should consider these all components. This study proposes the control method to reduced the circulating currents under the unbalanced voltage.

  • PDF

비대칭 불평형 전압 운전시 유도전동기의 동작 특성 해석 (Analysis on the Operation Characteristics of Induction Motor Operated by Asymmetric Unbalanced Voltage)

  • 김종겸;손홍관;정종호;이은웅
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.58-64
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance is a condition in a polyphase system in which the rms values of the line-to-line voltages or the phase angles between consecutive line-to-line voltages, are not all equal. Slight voltage unbalance generates a disproportionately high current unbalance at the motor stator winding. This paper presents a scheme on operation states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

실시간 시뮬레이터를 이용한 1MW 전력변환장치의 3상 불평형 비간섭 전류제어 검증 (Three-Phase Decoupled Current Control under Unbalanced Condition for 1MW Power Conditioning System)

  • 김원경;박기우;이지헌;고광수;이윤재;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.425-426
    • /
    • 2015
  • 본 논문에서는 실시간 시뮬레이터를 이용하여 1MW PCS(Power Conditioning System)의 불평형 비간섭 전류제어(Unbalanced Current Control under Unbalanced Condition) 알고리즘을 검증하였다. 3상 불평형 발생 시, 기존의 전류제어는 전압의 불안정으로 인해 전류의 목표 값이 흔들리는 현상을 보인다. 하지만, 3상 불평형 비간섭 제어는 불평형 상황 전압과 전류를 정상과 역상 성분으로 나누고, 이를 독립적으로 제어함으로써 더욱 우수한 성능을 가진다. 본 논문은 1MW PCS의 HILS(Hardware-In-the-Loop Simulation) 환경을 구축하여 실시간 시뮬레이터에서 실제 출력되는 전류의 불평형을 확인하고, 이를 개선하는 것을 검증하였다.

  • PDF

Design of a Hybrid Controller for the Three-phase Four-leg Voltage-source Inverter with Unbalanced Load

  • Doan, Van-Tuan;Kim, Ki-Young;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.181-189
    • /
    • 2017
  • The three-phase four-leg voltage-source inverter topology is an interesting option for the three-phase four-wire system. With an additional leg, this topology can achieve superior performance under unbalanced and nonlinear load conditions. However, because of the low bandwidth of conventional controllers in high-power inverter applications, the system cannot guarantee a balanced output voltage under the unbalanced load condition. Most of the methods proposed to solve this problem mainly use the multiple synchronous frame method, which requires several controllers and a large amount of computation because of frame transformation. This study proposes a simple hybrid controller that combines proportional-integral (PI) and resonant controllers in the synchronous frame synchronized with the positive-sequence component of the output voltage of the three-phase four-leg inverter. The design procedure for the controller and the theoretical analysis are presented. The performance of the proposed method is verified by the experimental results and compared with that of the conventional PI controller.

선박 자세안정성 향상을 위한 Anti-heeling Pump용 100kW급 IPM 전동기의 편심에 의한 전자기 가진력 분석 (Analysis of Electromagnetic Vibration Sources in 100kW Interior Permanent Magnet Motor for Ship Anti-heeling Pump Considering Eccentricity)

  • 이선권;강규홍;허진
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2230-2235
    • /
    • 2011
  • The purpose of this paper is to provide the unbalanced magnetic force and vibration mode comparison between two large interior permanent magnet machines(IPM) with different pole-slot combination considering stator and rotor eccentricity. Due to the punching tolerance, the mixed eccentricity of air-gap is inevitable. It will generate the asymmetric magnetic flux density in air-gap, which makes the unbalanced magnetic pull and vibration. The study is focused on the unbalanced magnetic force and their harmonic components according to eccentricity conditions such as static, dynamic and mixed. When the high vibration is produced especially resonance, the obtained results provide clues what eccentricity condition occurs in the machine.

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.