• Title/Summary/Keyword: Unbalanced Force

Search Result 121, Processing Time 0.027 seconds

The Effect of Nonuniform Magnetization in Permanent Magnet BLOC Motor (영구자석의 자화분포 불균일이 BLDC 전동기의 특성에 미치는 영향)

  • Park, S.C.;Yoon, T.H.;Kwon, B.I.;Yoon, H.S.;Won, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.40-42
    • /
    • 1998
  • Magnetization distribution in the ring magnet for BLDC motor is generally nonuniform because the structure of mutipole magnetizer is not symmetry and the air gap is not uniform. In this paper, the effect of the nonuniform magnetization on characteristics of the motor such as torque ripple, unbalanced force and current is examined. Time stepped finite element method is used for electromagnetic field analysis.

  • PDF

Controlling the surface energy and electrical properties of carbon films deposited using unbalanced facing target magnetron sputtering plasmas

  • Javid, Amjed;Kumar, Manish;Yoon, Seok Young;Lee, Jung Heon;Han, Jeon Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.231.1-231.1
    • /
    • 2015
  • Surface energy, being an important material parameter to control its interactions with the other surfaces plays a key role in bio-related application. Carbon films are found very promising due to their characteristics such as wear and corrosion resistant, high hardness, inert, low resistivity and biocompatibility. The present work deals with the deposition of carbon films using unbalanced facing target magnetron sputtering technique. The discharge characteristics were studied using optical emission spectroscopy and correlated with the film properties. Surface energy was investigated through contact angle measurement. The ID/IG ratio as calculated from Raman spectroscopy data increases with the increase in power density due to the higher number of sp2 clusters embedded in the amorphous matrix. The deposited films were smooth and homogeneous as observed by Atomic force microscopy having RMS roughness in the range of 1.74 to 2.25 nm. It is observed that electrical resistivity and surface energy varies in direct proportionality with operating pressure and has inverse relation with power density. The surface energy results clearly exhibited that these films can have promising applications in cell cultivation.

  • PDF

Nucleation and growth mechanism of nitride films deposited on glass by unbalanced magnetron sputtering

  • Jung, Min J.;Nam, Kyung H.;Han, Jeon G.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.06a
    • /
    • pp.14-14
    • /
    • 2001
  • Nitride films such as TiN, CrN etc. deposited on glass by PVD processes have been developed for many industrial applications. These nitride films deposited on glass were widely used for not only decorative and optical coatings but also wear and corrosion resistance coatings employed as dies and molds made of glass for the example of lens forming molds. However, the major problem of nitride coatings on glass by PVD process is non-uniform film owing to pin-hole and micro crack. It is estimated that nonuniform coating is influenced by a different surface energy between metal nitrides and glass due to binding states. In this work, therefore, for the evaluation of nucleation and growth mechanism of nitride films on glass TiN and CrN film were synthesized on glass with various nitrogen partial pressure by unbalanced magnetron sputtering. Prior to deposition, for the examination of relationship between surface energy and film microstructure plasma pre-treatment process was carried out with various argon to hydrogen flow rate and substrate bias voltage, duty cycle and frequency by using pulsed DC power supply. Surface energy owing to the different plasma pre-treatment was calculated by the measurement of wetting angle and surface conditions of glass were investigated by X-ray Photoelectron Spectroscopy(XPS) and Atomic Force Microscope(AFM). The microstructure change of nitride films on glass with increase of film thickness were analyzed by X-Ray Diffraction(XRD) and Scanning Electron Microscopy(SEM).

  • PDF

Nucleation and growth mechanism of nitride films deposited on glass by unbalanced magnetron sputtering (마그네트론 스퍼터링에 의하여 다양한 기판 위에 증착된 CrN 박막의 핵생성과 성장거동)

  • 정민재;남경훈;한전건
    • Journal of Surface Science and Engineering
    • /
    • v.35 no.1
    • /
    • pp.33-38
    • /
    • 2002
  • For the evaluation of nucleation and growth behaviors influenced by substrate properties, such as surface energy, structure and electrical properties, chromium nitride films (CrN) were deposited on various substrates (glass, AISI 1040 steel and Si (110) by unbalanced magnetron sputtering. X-ray diffraction and Atomic Force Microscopy (AFM) were used to study the microstructure and grain growth as a function of deposition time. The diffraction patterns of CrN thin films deposited on Si (110) exhibited crystalline structure with highly preferred orientation of (200) plane parallel to the substrate, whereas the films deposited on glass and AISI 1040 exhibited preferred orientations (200) and minor orientation (111), (311) or (220) plane. The orientation of films deposited both on glass and Si substrates did not depend on the bias voltage (Vs). The grain growth and structure of film deposited on AISI 1040 steel substrate are strongly influenced by the substrate bias in comparison with that deposited onto glass and Si substrates. The differences in the structure and grain growth of CrN films deposited onto different substrates are predominantly related to the properties of the substrate (structure and electrical conductivity).

Deformability of Flat Plate Subjected to Unbalanced Moment (불균형 휨모멘트를 받는 플랫 플레이트의 변형능력)

  • Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.482-493
    • /
    • 2003
  • Flat plate structures subjected to lateral load have less deformability than conventional moment frames, due to the brittle failure of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed to investigate the deformability of flat plates. The numerical results show that as number of continuous spans increases, the deformability of flat plates considerably decreases. Therefore, existing experiments using sub-assemblages with 1 or 2 spans may overestimate the deformability of flat plates, and current design provisions based on the experiments may not be accurate in estimating the deformability. A design method estimating the deformability was developed on the basis of numerical results, and verified by comparison with existing experiment. In the proposed method, the effects of primary design parameters such as direct shear force, punching shear capacity, aspect ratio of connection, number of spans, and initial stiffness of plate can be considered.

Estimation of Pump Induced Vibration Force by Frequency Response Function (진동수응답함수 측정에 따른 펌프 가진력 산정)

    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.103-112
    • /
    • 1999
  • This is study to estimate the pump induced vibration in time and frequency domain by frequency response function between two points in case of 20Hp and 50Hp centrifugal pumps. The frequency response function has real and imaginary information of signals, and response function has also real and imaginary information. So the vibration force can be obtained from the response function and frequency response function by complex calculation. And it is compared with the theoretically estimated values and it is suggested that the amplitude of vibration with main frequency is about 10~25% of pump and motor weight, and the magnitude of unbalanced mass is about 30~60% of pump and motor weight to estimated vibration force in time domain. There are the other kinds of vibration components with different frequency values of 2~3 times of its main frequency, and these kinds of information are used to control the tuning ratio between operating frequency of pump and structural frequency of concrete slab.

  • PDF

The influence of dynamic force balance on the estimation of dynamic uniaxial compression strength (암석시료 내 동적하중 분배특성이 동적일축압축강도에 미치는 영향성에 관한 연구)

  • Oh, Se-Wook;Min, Gyeong-Jo;Park, Se-Woong;Park, Hoon;Suk, Chul-Gi;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.37 no.1
    • /
    • pp.14-23
    • /
    • 2019
  • It has been an always issue for the blasting or the impact analysis to consider the strength characteristics of the rock materials associate with loading rate dependency. Due to the nature of transient loading, the dynamic rock test requires a careful technique to achieve the stress equilibrium state of the specimen. In this study, to investigate the relationship between the rock dynamic strength and the stress equilibrium state, a series of dynamic uniaxial compression tests for Pocheon granite were performed. As a result, the unbalanced stress state on the specimen can lead to the premature failure on the specimen and the less estimation of dynamic strength characteristic as well as the overestimation of strain rate. Consequently, a careful consideration of rock fracture process to achieve the dynamic force balance on the specimen should be required to make an reasonable evaluation of rock dynamic strength.

The Inclination Characteristics of PSC BOX in FCM Bridge Construction Method (FCM 교량 가설 공법에서 주두부의 기울음 특성)

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.12-20
    • /
    • 2023
  • This study presents basic data on how to secure stability by analyzing the change in tensile force of steel rod and the inclination characteristics of PSC BOX in the "Temporary fixation system using internal prestressing tendon", which is mainly applied to construction of superstructures by FCM. To date, it has been difficult to confirm the changes in tension force of the steel rod and the inclination of the PSC BOX because the steel rod was installed vertically inside the pier and the PSC BOX. Therefore, measurement of the change in length of the steel rod and the displacement of PSC BOX were performed using a micro-measured FBG sensor. Comparisons of the calculated tensile force and the residual tensile force of the steel rod revealed that the safety factor decreased in all bridges. The cause was mainly identified to be the loss of tensile force in fixation~1segment, and countermeasures are suggested. The analysis of the inclination characteristics showed that the inclination increased with the segment progresses even in bridges with sufficient safety factor, and the difference before and after the segment was confirmed. In addition, the increase in inclination was related to the loss of tension force in the steel rod, and the stress on the opposite sides of the inclination was further reduced. It is believed that upward tensile force is generated in the steel rod on the opposite side of the inclined side due to the unbalanced moment, causing the difference in stress of the steel rod between the two sides.

Sluice Gates Control Monitoring of Oil Pressure-Machine Using FDC Tuning Control Technique (FDC 동조제어기법을 이용한 유압-기계식 수문 제어 모니터링)

  • Heo, Gwanghee;Kim, Chunggil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.337-342
    • /
    • 2010
  • Generally most sluice gates are closed and opened by a mechanical winch, a winch using an oil-pressure, or a winch mixing both. Because of their size and structure, they should be safely operated with more than two pulling devices helping each other. At the moment of their opening and closing, there usually occur some additional loads to the structure which cannot be exactly measurable at the stage of designing. Such additional loads can cause the sluice gate to be unbalanced and make it hard to open and close the gate, and by also overloading a winch, they can inflict a significant damage to the safety of the sluice gate. This paper explains a FDC(Force-Displacement Control) system which simultaneously considered the oil-pressure and displacement in order to evenly distribute the force and make a winch balanced at the opening and closing motion. This FDC system was implemented by means of the PID(Proportional Integral Derivative) function of XG 5000 program. It was experimented on a model of the sluice gate winch with the hydraulic oil pressure cylinder. The experiments showed that the developed FDC system made the winch of hydraulic oil pressure cylinder open and close cooperatively in spite of various external loads. Therefore the FDC system is proven effective when it is applied to a winch of sluice gate.

Assist Torque Balance Control for Power Assisted Wheelchair Based on Temporal Similarity between Input Torques (입력토크의 시간적 유사성에 기반한 파워 어시스트 휠체어의 토크 밸런스 제어)

  • Heo, Y.;Hong, E.P.;Ryu, J.C.;Moon, M.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.81-87
    • /
    • 2015
  • In order for a Power Assisted Wheelchair (PAW) to maintain a straight driving direction, the same force must be delivered to both wheels. However, a human has different strength between the right and left arms, and cannot control the force uniformly at all times. Therefore, appropriate assist torque shall be generated from unbalanced human torque inputs by detecting the user intention, in order to maintain direction uniformly in straight sections or change direction quickly in curved sections. In this study, a special function is proposed to detect the intention of drivers on the basis of temporal similarity between the input torque signals, and a torque balancing technique based on this function is proposed. In the experiments, the effectiveness of the proposed torque balancing method are verified.

  • PDF