• Title/Summary/Keyword: Un-cooled

Search Result 21, Processing Time 0.025 seconds

Image Correction Method for Uncooled IR TECless Detector with Non-linear characteristics due to Temperature Change

  • Shin, Jung-Ho;Ye, Seong-Eun;Kim, Bo-Mee;Park, Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.10
    • /
    • pp.19-26
    • /
    • 2017
  • In this paper, we propose an efficient image equipment implementation for the detector characteristics of various detectors by analyzing un-cooled thermal detector that exhibits nonlinear changes due to external temperature effects. First, we explain Thermal Electric Cooler for un-cooled detector temperature control system and Non-image correction methode for IR system. Second, we present the results of a study on an efficient control technique that can minimize the deterioration of image quality by controlling a un-cooled thermal detector without a thermal electric cooler(TEC) inside. Third, we suggest Image Correction Methods for Uncooled IR TECless Detector with Non-linear characteristics due to Temperature Change. So, we analyze and present the results of Image correction methods for various un-cooled thermal detector.

Low Power IR Module Design for Small Arms Using Un-cooled Type Detector (비냉각 검출기를 이용한 소화기용 저전력 열상모듈 설계)

  • Sung, Gi-Yeul;Kwak, Dong-Min;Kwak, Ki-Ho;Kim, Do-Jong;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.138-144
    • /
    • 2007
  • This paper introduces the design techniques of an IR module using the 2-D array un-cooled type infrared detector which is applied to the individual combat weapon. Considering the size and weight of the hand carried weapon system, we used a very small-sized detector and applied an adaptive temperature control algorithm so that the operation consumed with low power can be possible. We applied the AR(Auto Regressive) filter to improve the signal-to-noise ratio in a thermal image processing step. We also applied the plateau equalization and boundary enhancement techniques to improve the visibility for human visual system.

Thermal-hydraulic analysis of a new conceptual heat pipe cooled small nuclear reactor system

  • Wang, Chenglong;Sun, Hao;Tang, Simiao;Tian, Wenxi;Qiu, Suizheng;Su, Guanghui
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.19-26
    • /
    • 2020
  • Small nuclear reactor features higher power capacity, longer operation life than conventional power sources. It could be an ideal alternative of existing power source applied for special equipment for terrestrial or underwater missions. In this paper, a 25kWe heat pipe cooled reactor power source applied for multiple use is preliminary designed. Based on the design, a thermal-hydraulic analysis code for heat pipe cooled reactor is developed to analyze steady and transient performance of the designed nuclear reactor. For reactor design, UN fuel with 65% enrichment and potassium heat pipes are adopted in the reactor core. Tungsten and LiH are adopted as radiation shield on both sides of the reactor core. The reactor is controlled by 6 control drums with B4C neutron absorbers. Thermoelectric generator (TEG) converts fission heat into electricity. Cooling water removes waste heat out of the reactor. The thermal-hydraulic characteristics of heat pipes are simulated using thermal resistance network method. Thermal parameters of steady and transient conditions, such as the temperature distribution of every key components are obtained. Then the postulated reactor accidents for heat pipe cooled reactor, including power variation, single heat pipe failure and cooling channel blockage, are analyzed and evaluated. Results show that all the designed parameters satisfy the safety requirements. This work could provide reference to the design and application of the heat pipe cooled nuclear power source.

Residual Stress Analysis of Hot Rolled Strip (열연 강판의 잔류 응력 해석)

  • 구진모;김홍준;이재권;황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.172-175
    • /
    • 2003
  • Run-Out-Table is the region between EDT and CT. Hot killed strip is cooled by air and water in ROT. In this procedure, phase transformation and shape deformation occur due to temperature drop. Because of un-ideal cooling condition, deformation of strip and non-uniform phase distribution come into existence. This phenomenon affects the strip property and lead th the existence of residual stress. And it exerts effects on the Coiling process, Coil Cooling process, and Un-coiling process. Through these process, the residual stresses of strip are more larger and unbalance of these stresses become more severe. Finite element (FE) based models for the analysises of non-steady state heat transfer and elastoplastic deformation are described in this investigation. The analysises of thermodynamics and phase transformation kinetics are suggested also. Using the ROT simulation result coiling process and coil cooling process simulations are carried out.

  • PDF

A Novel Test Structure for Process Control Monitor for Un-Cooled Bolometer Area Array Detector Technology

  • Saxena, R.S.;Bhan, R.K.;Jalwania, C.R.;Lomash, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.299-312
    • /
    • 2006
  • This paper presents the results of a novel test structure for process control monitor for uncooled IR detector technology of microbolometer arrays. The proposed test structure is based on resistive network configuration. The theoretical model for resistance of this network has been developed using 'Compensation' and 'Superposition' network theorems. The theoretical results of proposed resistive network have been verified by wired hardware testing as well as using an actual 16x16 networked bolometer array. The proposed structure uses simple two-level metal process and is easy to integrate with standard CMOS process line. The proposed structure can imitate the performance of actual fabricated version of area array closely and it uses only 32 pins instead of 512 using conventional method for a $16{\times}16$ array. Further, it has been demonstrated that the defective or faulty elements can be identified vividly using extraction matrix, whose values are quite similar(within the error of 0.1%), which verifies the algorithm in small variation case(${\sim}1%$ variation). For example, an element, intentionally damaged electrically, has been shown to have the difference magnitude much higher than rest of the elements(1.45 a.u. as compared to ${\sim}$ 0.25 a.u. of others), confirming that it is defective. Further, for the devices having non-uniformity ${\leq}$ 10%, both the actual non-uniformity and faults are predicted well. Finally, using our analysis, we have been able to grade(pass or fail) 60 actual devices based on quantitative estimation of non-uniformity ranging from < 5% to > 20%. Additionally, we have been able to identify the number of bad elements ranging from 0 to > 15 in above devices.

Measuring Particle Number from Light-duty Diesel Vehicles in WLTP Driving Cycle (WLTP 주행모드에서의 경유차 입자상물질 개수 배출 특성)

  • Park, Junhong;Lee, Jongtae;Kim, Jeongsoo;Kim, Sunmoon;Ahn, Keunhwan
    • Journal of ILASS-Korea
    • /
    • v.18 no.3
    • /
    • pp.155-160
    • /
    • 2013
  • Worldwide harmonized light-duty vehicle test procedure (WLTP) for emission certification has been developed in WP.29 forum in UN ECE since 2007. The test procedure is expected to be applied to Korean light-duty diesel vehicles at the same time of adoption in Europe. The air pollutant emissions from light-duty vehicles have been regulated with weight per distance travelled which means the driving cycles can affect the results. The six Euro-5 light-duty diesel vehicles including sedan, SUV and truck have been tested with WLTP, NEDC which is used for emission certification for light-duty diesel vehicles, and CVS-75 to estimate how much particle number emission can be affected by different driving cycles. The averaged particle number emissions have not shown statistically meaningful difference. The maximum particle number emission have been found in Low speed phase of WLTP which is mainly caused by cooled engine conditions. The amount of particle number emission in cooled engine condition is much different as test vehicles. It means different technical solution is required in this aspect to cope with WLTP driving cycle.

Up-cycling of Air-cooled Ladle Furnace Slag : Environmental Risk Assessment and Mortar Compressive Strength Assesment of Binary and Ternary Blended Cement Using Air-cooled Ladle Furnace Slag (전기로 환원슬래그 Up-cycling : 환경위해성 평가 및 환원슬래그를 혼합하여 제조한 2성분계 및 3성분계 혼합시멘트 모르타르 압축강도 평가)

  • Cho, Han Sang;Mun, Young Bum;Moon, Won Sik;Park, Dae Cheol;Kim, Hyeong Cheol;Choi, Hyun Kook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.159-164
    • /
    • 2015
  • This study investigated the environmental risk for up-cycling of air-cooled ladle furnace slag (LFS) and evaluated the mortar compressive strength of binary and ternary blended cements using LFS of 3, 5, 10 wt%. Based on the Soil Environment Conservation Act standard, there was no environmental risk of the up-cycling of LFS. Results of mortar compressive strength assesment showed that the compressive strength of two blended cements using LFS of lower than 5 wt% was about 1.1 times superior to that of un-substituted cement (ordinary portland cement, OPC); however the compressive strength of those with LFS of 10 wt% decreased with 10% compared with that of OPC.

Preparation and Evaluation of the Controlled-release Dosage Form of Amoxicillin (제어방출형 Amoxicillin제제의 제조 및 평가)

  • Jee, Ung-Kil;Jeon, Un-Jong;Lee, Gye-Won;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.167-176
    • /
    • 1994
  • The microcapsules of amoxicillin using stearyl alcohol and polyethyleneglycol 8000 (PEG 8000) were prepared by a emulsion melted-cooled process in water phase. The size distribution, dissolution test, observation with SEM and in vivo test were investigated. The microcapsules obtained were spherical, uniform and free flowing particles. The release of drug from microcapsule was increased in proportional to the content of PEG 8000. As the PEG 8000 content increased, the particle size of microcapsule was decreased. Sanning electron micrograph study revealed that microcapsules had comparatively rough surfaces as drug content was increased. The $AUC_{0-12}$ after administration of amoxicillin microcapsules was more increased 40% as compared with the AUC after administration of amoxicillin powder in rabbits.

  • PDF

Formation and Growth of Hydride Blisters in Zr-2.5Nb Pressure Tubes

  • Cheong, Yong-Moo;Gong, Un-Sik;Choo, Ki-Nam;Kim, Sung-Soo;Kim, Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.192-200
    • /
    • 2001
  • Hydride blisters were formed on the outer surface of Zr-2.5Nb pressure tube by a non- uniform steady thermal diffusion process. A thermal gradient was applied to the pressure tube with a heat bath kept at a temperature of 415$^{\circ}C$ and an aluminum cold finger cooled with flowing water of 15$^{\circ}C$. Optical microscopy and tree-dimensional laser profilometry were used to characterize the hydride blisters with different hydrogen concentrations and thermal diffusion time. Hydride blisters were expected to start at a hydrogen concentration of 30 - 70 ppm and a thermal diffusion time of 4 - 6$\times$10$^{5}$ sec. The hydride blister size increases with higher hydrogen concentrations and longer thermal diffusion time . Some of the samples revealed cracks on the hydride blisters. The ratio of hydride blister depth to height was estimated as approximately 8: 1.

  • PDF