• Title/Summary/Keyword: Ultrasound technology

Search Result 493, Processing Time 0.032 seconds

Examination Techniques and Imaging Findings of Hepatic Hemangioma (간혈관종의 검사기법과 영상소견)

  • Chang-Hoe Koo;Jong-Wan Keum;Ji-Eun Seok;Dong-Chul Choi;Yun-Ho Choi;Man-Seok Han;Min-Cheol Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.375-384
    • /
    • 2023
  • Most Hepatic hemangiomas are asymptomatic and small in size, making them difficult to find by pathological examination. Therefore, radiological diagnosis is essential for the early finding and diagnosis of Hepatic hemangioma. Three-phase method using contrast medium in computed tomography, T1, T2-weighted imaging in magnetic resonance imaging, dynamic magnetic resonance imaging using contrast medium, echo planar imaging method, diffusion-weighted imaging method, blood pool scan using 99mTc-labeled red blood cells in nuclear medicine, we looked at the color doppler method In ultrasound, and it is important to accurately understand the imaging findings of hepatic hemangioma and perform the examination in order to make an accurate diagnosis. most hepatic hemangioma are benign tumors, care should be taken not to confuse them with malignant tumors such as hepatocellular carcinoma to prevent unnecessary procedures. Therefore, in order to make an accurate diagnosis, it is important to accurately understand the imaging findings of hemangioma and perform the examination.

Monte Carlo Simulations of Selection Responses for Improving High Meat Qualities Using Real Time Ultrasound in Korean Cattle (초음파측정 활용 고급육형 한우개량을 위한 선발반응 Monte Carlo 모의실험)

  • Lee, D. H.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-354
    • /
    • 2003
  • Simulation studies were carried out to investigate the responses of selection for three carcass traits (longissimus muscle area: EMA, fat thickness: BF, and marbling score: MS) based on either adjusted phenotypes (APH) or estimated breeding values (EBV) in multivariate animal model with different breeding schemes. Selection responses were estimated and compared on six different models with respect to breeding schemes using either carcass measurements or real time ultrasonic (RTU) scans generated by Monte Carlo computer simulation supporting closed breeding population. From the base population with 100 sires and 2000 dams, 20 sires and 1000 dams by each generation were selected by either APH or EBV for 10 generations. Relative economic weights were equal of three traits as EMA(1): BF(-1) : MS(1) for standardized either APH or EBV. For first two models which were similarly designed with current progeny-test program in Korean cattle, three carcass traits with records either only on male progenies (Model 1) or on male and female progenies (Model 2) were used for selecting breeding stocks. Subsequently, generation intervals on males were assumed as 6${\sim}$10 years in these two models. The other two models were designed with tools of selection by RTU rather than carcass measurements with genetic correlations of 0.81${\sim}$0.97 between RTU and corresponding carcass traits in addition to whether with records (Model 4) or without records (Model 3) on female. In these cases, generation intervals on males were assumed as 2${\sim}$4 years. The remaining last two models were designed as similar with Models 3 and 4 except genetic correlations of 0.63${\sim}$0.68 between RTU and corresponding carcass traits with records (Model 6) and without records (Model 5) on females. The results from 10 replicates on each model and selecting methods suggested that responses indirect selection for carcass traits in Model 4 were 1.66${\sim}$2.44 times efficient rather than those in Model 1. Otherwise, in Model 6 with assuming moderate genetic correlations, those efficiencies were 1.18${\sim}$2.08 times with comparing to responses in Model 1. However, selection response for marbling score was the smallest among three carcass traits because of small variation of measurements. From these results, this study suggested that indirect selection using RTU technology for improving high meat qualities in Korean cattle would be valuable with modifying measuring rules of marbling score forward to large variation or modifying relative economic weight for selection.

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.

Application of AutoFom III equipment for prediction of primal and commercial cut weight of Korean pig carcasses

  • Choi, Jung Seok;Kwon, Ki Mun;Lee, Young Kyu;Joeng, Jang Uk;Lee, Kyung Ok;Jin, Sang Keun;Choi, Yang Il;Lee, Jae Joon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.10
    • /
    • pp.1670-1676
    • /
    • 2018
  • Objective: This study was conducted to enable on-line prediction of primal and commercial cut weights in Korean slaughter pigs by AutoFom III, which non-invasively scans pig carcasses early after slaughter using ultrasonic sensors. Methods: A total of 162 Landrace, Yorkshire, and Duroc (LYD) pigs and 154 LYD pigs representing the yearly Korean slaughter distribution were included in the calibration and validation dataset, respectively. Partial least squares (PLS) models were developed for prediction of the weight of deboned shoulder blade, shoulder picnic, belly, loin, and ham. In addition, AutoFom III's ability to predict the weight of the commercial cuts of spare rib, jowl, false lean, back rib, diaphragm, and tenderloin was investigated. Each cut was manually prepared by local butchers and then recorded. Results: The cross-validated prediction accuracy ($R^2cv$) of the calibration models for deboned shoulder blade, shoulder picnic, loin, belly, and ham ranged from 0.77 to 0.86. The $R^2cv$ for tenderloin, spare rib, diaphragm, false lean, jowl, and back rib ranged from 0.34 to 0.62. Because the $R^2cv$ of the latter commercial cuts were less than 0.65, AutoFom III was less accurate for the prediction of those cuts. The root mean squares error of cross validation calibration (RMSECV) model was comparable to the root mean squares error of prediction (RMSEP), although the RMSECV was numerically higher than RMSEP for the deboned shoulder blade and belly. Conclusion: AutoFom III predicts the weight of deboned shoulder blade, shoulder picnic, loin, belly, and ham with high accuracy, and is a suitable process analytical tool for sorting pork primals in Korea. However, AutoFom III's prediction of smaller commercial Korean cuts is less accurate, which may be attributed to the lack of anatomical reference points and the lack of a good correlation between the scanned area of the carcass and those traits.

Location Studies of Prostate Volume Measurement by using Transrectal Ultrasonography: Experimental Study by Self-Produced Prostate Phantom (경직장초음파를 이용한 전립선 볼륨측정 시의 위치 연구: 전립선모형 제작과 실험)

  • Kim, Yun-Min;Yoon, Joon;Byeon, II-kyun;Lee, Hoo-Min;Kim, Hyeong- Gyun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.437-442
    • /
    • 2015
  • Accurate volume measurement of the prostate is a significant role in determining the result of diagnosis and treatment of benign prostate hyperplasia. The purpose of this study was to determine, when measuring prostate volume by TRUS, whether location is more accurately determined by transaxial or longitudinal scanning. With reference to the patient's image, it was produced six prostate model. It compares the actual volume and the measurement volume, and find the optimal measurement position of each specific model. Prostate volume measured by TRUS closely correlates with prostate phantom volume. There was no significant difference(p = .156). To measure the accurate volume of prostate with focal protrusion, its length should be measured exclude the protrusions.

A study on the fabrication of lithium carbonation powder by gas-liquid reaction using ultrasonic energy (탄산리튬 분말 제조에 있어서 초음파 에너지를 적용한 기액반응에 관한 연구)

  • Kim, Dae-Weon;Kim, Bo-Ram;Choi, Hee-Lack
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2020
  • In the previous study, we reported the result to prepare lithium carbonate powder from various lithium-contained solution. Therefore, using the lithium hydroxide solution, it is conformed that the reaction could occur thermodynamically, and the recovery rate of lithium was 89.4 %. In this study, we carried out the experiment to prepare lithium carbonate powder through gas-liquid reactions with lithium hydroxide solution and CO2 gas using ultrasound energy. In case ultrasonic energy is applied to the reaction of lithium carbonate, the recovery rate of lithium at room temperature was approximately 83.8 %, and the recovery rate of lithium was greatly increased to approximately 99.9 % at 60℃ reaction temperature. And when ultrasonic energy is not applied, the particle size of lithium carbonate powder was 7.7 ㎛ in D50. But the particle size of lithium carbonate powder was significantly reduced to 8.4 ㎛ in D50 under the influence of ultrasonic.

Effect of oil particle size on dispersion stability in oil in water emulsion (Oil in Water 에멀전에서 오일 입자 크기가 분산 안정성에 미치는 영향)

  • Hwangbo, Sunae;Chu, Minchul;Moon, Changkwan
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.133-139
    • /
    • 2017
  • In this paper, we proposed an emulsification method without using an emulsifier and investigated the effects of particle size distribution in fluids on dispersion stability. Surfactant-free oil in water emulsion was prepared with 1 % (w/w) of olive oil by using high speed agitation, high pressure and ultrasonic dispersion methods. The particle size, microscopic observation, and dispersion stability of each sample were evaluated and dispersion stability according to various dispersion methods was compared. As a result, the emulsion dispersed by the ultrasonic dispersion method showed the smallest particle size and uniform distribution of $0.07{\sim} 0.3{\mu}m$ and was the most stable in a 7 days stability evaluation. In the above experiment, four olive oil emulsions having different particle sizes were prepared using ultrasonic dispersion technology that was capable of producing stable emulsions. The dispersion stability of each samples with oil droplet sizes of (A) 0.1 to $0.5{\mu}m$, (B) 0.3 to $4{\mu}m$, (C) 1 to $10.5{\mu}m$ and (D) 2 to $120{\mu}m$, was observed for 7 days, and the relationship between the stability and performance was studied. Emulsion (A) with particle size less than $0.5{\mu}m$ displayed the dispersion stability showing below 5 % change in a 7 days stability evaluation. In the case of (B), (C), and (D) that had larger particle than $0.5{\mu}m$, the changes of dispersion stability were 10 %, 13 % and 35 % respectively. From these results, it was proved that dispersion stability of emulsion with uniform particle size of $0.5{\mu}m$ or less was confirmed to be very stable.

The Study of Ibuprofen Degradation Properties by Combination of Wave Energy (Ultrasound, Ultraviolet) and Persulfate Ion (파 에너지 (자외선, 초음파)/과황산나트륨을 이용한 이부프로펜 분해특성 연구)

  • Na, Seungmin;Ahn, Yungyong;Cui, Mingcan;Son, Younggu;Khim, Jeehyeong
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.963-972
    • /
    • 2014
  • In this study, ibuprofen(IBP) degradation by the photochemical ($UV/S_2O{_8}^{2-}$) and sonochemical ($US/S_2O{_8}^{2-}$) processes was examined under various parameters, such as UV ($10{\sim}40{\pm}5W/L$) and US ($50{\sim}90{\pm}5W/L$) power density, optimum dosage of persulfate ion ($S_2O{_8}^{2-}$), temperature ($20{\sim}60^{\circ}C$) and anions effect ($Cl^-$, $HCO_3{^-}$, $CO{_3}^{2-}$). The pseudo-first-order degradation rate constants were in the order of $10^{-1}$ to $10^{-5}min^{-1}$ depending on each processes. The synergistic effect of IBP degradation in $UV/S_2O{_8}^{2-}$ and $US/S_2O{_8}^{2-}$ processes could investigated, due to the generation of $SO_4{^-}$ radical. This result can confirm from the produced $H_2O_2$ and $SO{_4}^{2-}$ concentration in each processes. IBP degradation rate affected by the $S_2O{_8}^{2-}$ dosage, temperature, power and anion existence parameters. In particular, IBP degradation rate increased with the increase of the temperature ($60^{\circ}C$) and applied power density (UV:$40{\pm}5W/L$, US:$90{\pm}5W/L$). On the other hand, anions effect on the IBP degradation was negative, due to the anion play as a the scavenger of radical.

Actual Use of Internet in Curriculum Study of Students in Radiology (방사선 재학생 전공교과목 학습에서 인터넷 활용 실태)

  • Kim, Min-Cheol;Huang, Yuxin;Choi, Ji Hoon;Jung, Hong Ryang;Park, Hae-Ri;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.487-491
    • /
    • 2018
  • The purpose of this study was to analyze questionnaires of 161 college students attending radiology departments in order to investigate the actual condition of internet use of radiology students. As a result, 95% of college students using the Internet showed 5.8% of general knowledge, 56.9% of radiation major, and 45.8% of general education. In the field of Internet use, basic medicine was 71.2%, anatomy 59.5% and physiology 51.6%. Radiation theory was 39.9% in radiation physics, 31.4% in radiation biology, and 18.3% in radiation management. The radiological applications were followed by radiography and radiography in order of 31.4% and 20.3%, respectively. The radiological imaging was 45.8%, MRI was 37.9%, CT was 37.3%, ultrasound was 24.2%, And radiation nuclear medicine 25.5%. The results of the descriptive statistics of the satisfaction of the contents using the Internet media showed that the overall satisfaction was below 2.5 Based on the results of this study, it is necessary to develop a program with high accessibility to provide various opportunities for internet-based opportunities to increase the academic achievement value of major subjects through the internet and to solve the difficulties in the major subject.

A Study on Microbial Contamination and Disinfection of Ultrasonic Probe in Metropolitan Area (수도권 지역의 초음파 프로브의 미생물 오염도와 소독에 관한 연구)

  • Lee, Hyun Kyung;Kim, Sam Soo;Heo, Yeong Cheol;Han, Dong Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.427-435
    • /
    • 2018
  • There was a shortage of research reports on sterilization criterion and contamination of ultrasonic probes. Therefore, in this study, we were going to provide a basic study to measure the level of microbial contamination in ultrasonic probes and to investigate the radiographer's awareness of infection. After the scan, samples were collected from the rubber part of the probe by opening a sterile swab (Transport Medium AM608-1S) for medical bacteria collection with the remaining gel removed with a paper towel. Also, the collected samples of bacteria were grown for seven days and then the laboratory was analyzed. Among the total 29 types of microorganisms, Micrococcus luteus 21(26%), Moraxella species 16(20%), Coagulase negative staphylococcus 8(10%), Bacillus species 5(7%), Bicillus circulans 3(5%), Acinetobacter lwoffii 2(2%), and 1 other Candida parapsilosis (1%) a number of bacteria and fungus, was detected. In a disinfectant experiment using LuciPac Pen on the Lumitester PD-30s, we cultured the rubber part of the probe two to three times to measure the bacteria. Bacteria decreased to 97% with Aquanax (alkaline reduced water 100%), 99% with Klarion wash (0.01% sodium hydroxide), 94% with Klarion disinfection (0.01% nitrous acid water), Sterilization was best with Klarion wash (0.01% sodium hydroxide). Therefore, guidelines for cleaning and disinfection of ultrasonic probes was required, and further development of probe-only disinfectants is required.