• 제목/요약/키워드: Ultrasound technology

검색결과 496건 처리시간 0.031초

Crack localization by laser-induced narrowband ultrasound and nonlinear ultrasonic modulation

  • Liu, Peipei;Jang, Jinho;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.301-310
    • /
    • 2020
  • The laser ultrasonic technique is gaining popularity for nondestructive evaluation (NDE) applications because it is a noncontact and couplant-free method and can inspect a target from a remote distance. For the conventional laser ultrasonic techniques, a pulsed laser is often used to generate broadband ultrasonic waves in a target structure. However, for crack detection using nonlinear ultrasonic modulation, it is necessary to generate narrowband ultrasonic waves. In this study, a pulsed laser is shaped into dual-line arrays using a spatial mask and used to simultaneously excite narrowband ultrasonic waves in the target structure at two distinct frequencies. Nonlinear ultrasonic modulation will occur between the two input frequencies when they encounter a fatigue crack existing in the target structure. Then, a nonlinear damage index (DI) is defined as a function of the magnitude of the modulation components and computed over the target structure by taking advantage of laser scanning. Finally, the fatigue crack is detected and localized by visualizing the nonlinear DI over the target structure. Numerical simulations and experimental tests are performed to examine the possibility of generating narrowband ultrasonic waves using the spatial mask. The performance of the proposed fatigue crack localization technique is validated by conducting an experiment with aluminum plates containing real fatigue cracks.

Effect of reducing sodium chloride based on the sensory properties of meat products and the improvement strategies employed: a review

  • Kim, Tae-Kyung;Yong, Hae In;Jung, Samooel;Kim, Hyun-Wook;Choi, Yun-Sang
    • Journal of Animal Science and Technology
    • /
    • 제63권4호
    • /
    • pp.725-739
    • /
    • 2021
  • Many consumers are concerned about the high levels of salt intake owing to the accompanied risk of chronic diseases. Due to this dietary concern, the food industry has recommended the reduction of salt content in many products. However, the addition of salt to meat products improves their quality and sensory properties, including saltiness, color, juiciness, and texture. Because quality deteriorations could induce decreased sensory scores owing to salt reductions, the challenges involved in improving the quality of reduced-salt meat products have been addressed. During the development of low-salt meat products, it is important to reduce sodium content and address the problems that arise with this reduction. Modified salt, organic acids, amino acids, nucleotides, hydrocolloids, high-pressure, ultrasound, electric pulsed field, and irradiation have been suggested as strategies to replace or reduce sodium content, and sensory scores could be improved by these strategies. Therefore, when developing a low-salt meat product, several perspectives must be considered and the latest technologies that could resolve this problem should be adopted.

Acoustic Estimation of Phase Velocity of Closed-Cell Kelvin Structure based on Spectral Phase Analysis

  • Kim, Nohyu
    • International Journal of Advanced Culture Technology
    • /
    • 제10권3호
    • /
    • pp.339-345
    • /
    • 2022
  • In this paper, the effect of porosity on the acoustic phase velocity of the 3D printed Kelvin closed-cell structure was investigated using the spectral phase analysis. Since Kelvin cells bring about the large amount of scattering, acoustic pulses in ultrasonic measurements undergoes a distortion of waveforms due to the dispersion effect. In order to take account on the dispersion, mathematical expressions for calculating the phase velocity of longitudinal waves propagating normal to the plane of the Kelvin structure are suggested by introducing a complex wave number based on Fourier transform. 3D Kelvin structure composed of identical unit-cells, a polyhedron of 14 faces with 6 quadrilateral and 8 hexagonal faces, was developed and fabricated by 3D CAD and 3D printer to represent the micro-structure of porous materials such as aluminum foam and cancellous bone. Total nine samples of 3D Kelvin structure with different porosity were made by changing the thickness of polyhedron. Ultrasonic pulse of 1MHz center frequency was applied to the Kelvin structures for the measurement of the phase velocity of ultrasound using the TOF(time-of-flight) and the phase spectral method. From the experimental results, it was found that the acoustic phase velocity decreased linearly with the porosity.

Development of a novel reconstruction method for two-phase flow CT with improved simulated annealing algorithm

  • Yan, Mingfei;Hu, Huasi;Hu, Guang;Liu, Bin;He, Chao;Yi, Qiang
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1304-1310
    • /
    • 2021
  • Two-phase flow, especially gas-liquid two-phase flow, has a wide application in industrial field. The diagnosis of two-phase flow parameters, which directly determine the flow and heat transfer characteristics, plays an important role in providing the design reference and ensuring the security of online operation of two-phase flow system. Computer tomography (CT) is a good way to diagnose such parameters with imaging method. This paper has proposed a novel image reconstruction method for thermal neutron CT of two-phase flow with improved simulated annealing (ISA) algorithm, which makes full use of the prior information of two-phase flow and the advantage of stochastic searching algorithm. The reconstruction results demonstrate that its reconstruction accuracy is much higher than that of the reconstruction algorithm based on weighted total difference minimization with soft-threshold filtering (WTDM-STF). The proposed method can also be applied to other types of two-phase flow CT modalities (such as X(𝛄)-ray, capacitance, resistance and ultrasound).

Respiratory Review of 2012: Bronchoscopic Innovations and Advances

  • Nam, Sung-Jin;Hwangbo, Bin
    • Tuberculosis and Respiratory Diseases
    • /
    • 제73권4호
    • /
    • pp.197-203
    • /
    • 2012
  • Recent advances in bronchoscopy have led to changes in clinical diagnostics and therapeutics in pulmonary medicine. In diagnostic bronchoscopy, there have also been new developments in endobronchial ultrasound technology which may be incorporated into clinical practice in the near future. Functional bronchoscopy, which evaluates information such as airway pressure, airflow, or gas exchange, suggests promising clinical advances in the near future. In therapeutic bronchoscopy, bronchoscopic volume reduction is a novel approach for the treatment of severe emphysema. In this review, seven recently published articles representing current advances in bronchoscopy are summarized and discussed.

Medical Image Compression using Adaptive Subband Threshold

  • Vidhya, K
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.499-507
    • /
    • 2016
  • Medical imaging techniques such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) and Ultrasound (US) produce a large amount of digital medical images. Hence, compression of digital images becomes essential and is very much desired in medical applications to solve both storage and transmission problems. But at the same time, an efficient image compression scheme that reduces the size of medical images without sacrificing diagnostic information is required. This paper proposes a novel threshold-based medical image compression algorithm to reduce the size of the medical image without degradation in the diagnostic information. This algorithm discusses a novel type of thresholding to maximize Compression Ratio (CR) without sacrificing diagnostic information. The compression algorithm is designed to get image with high optimum compression efficiency and also with high fidelity, especially for Peak Signal to Noise Ratio (PSNR) greater than or equal to 36 dB. This value of PSNR is chosen because it has been suggested by previous researchers that medical images, if have PSNR from 30 dB to 50 dB, will retain diagnostic information. The compression algorithm utilizes one-level wavelet decomposition with threshold-based coefficient selection.

소화기 내시경의 기술 현황과 전망 (Current and Future Technologies for a Gastrointestinal Endoscopy)

  • 지영준;우지환
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.335-343
    • /
    • 2010
  • This article presents a review of technologies for an endoscope. The classification according to the clinical applications and the imaging modalities are summarized. The major parts are focused on describing the gastrointestinal endoscope's structures and mechanisms. The details of the image enhanced endoscopic techniques, such as NBI (narrow band imaging), OCT (optical coherence tomography), and EUS (endoscopic ultrasound), are also explained. Finally, the trend of NOTES (natural orifice transluminal endoscopic surgery) which is new fusion technology in the field of endoscopic diagnosis and surgery is introduced.

Ganglion Cyst Region Extraction from Ultrasound Images Using Possibilistic C-Means Clustering Method

  • Suryadibrata, Alethea;Kim, Kwang Baek
    • Journal of information and communication convergence engineering
    • /
    • 제15권1호
    • /
    • pp.49-52
    • /
    • 2017
  • Ganglion cysts are benign soft tissues usually encountered in the wrist. In this paper, we propose a method to extract a ganglion cyst region from ultrasonography images by using image segmentation. The proposed method using the possibilistic c-means (PCM) clustering method is applicable to ganglion cyst extraction. The methods considered in this thesis are fuzzy stretching, median filter, PCM clustering, and connected component labeling. Fuzzy stretching performs well on ultrasonography images and improves the original image. Median filter reduces the speckle noise without decreasing the image sharpness. PCM clustering is used for categorizing pixels into the given cluster centers. Connected component labeling is used for labeling the objects in an image and extracting the cyst region. Further, PCM clustering is more robust in the case of noisy data, and the proposed method can extract a ganglion cyst area with an accuracy of 80% (16 out of 20 images).

Estimation of Hysteretic Interfacial Stiffness of Contact Surfaces

  • Kim, Nohyu
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.276-282
    • /
    • 2013
  • This paper proposes an ultrasonic method for measurement of linear and hysteretic interfacial stiffness of contacting surfaces between two steel plates subjected to nominal compression pressure. Interfacial stiffness was evaluated by the reflection and transmission coefficients obtained from three consecutive reflection waves from solid-solid surface using the shear wave. A nonlinear hysteretic spring model was proposed and used to define the quantitative interfacial stiffness of interface with the reflection and transmission coefficients. Acoustic model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves and to determine the linear and nonlinear hysteretic interfacial stiffness. Two identical plates are put together to form a contacting surface and pressed by bolt-fastening to measure interfacial stiffness at different states of contact pressure. It is found from experiment that the linear and hysteretic interfacial stiffness are successfully determined by the reflection and transmission coefficient at the contact surfaces through ultrasonic pulse-echo measurement.

형광기관지경의 미래 (Future of Autofluorescence Bronchoscopy)

  • 장태원
    • 대한기관식도과학회지
    • /
    • 제15권2호
    • /
    • pp.30-35
    • /
    • 2009
  • Lung cancer could be developed through a series of morphological changes from dysplasia to carcinoma in situ and then invasive cancer. However, precancerous lesions are generally a few cell layers thick and are detected only by chance. Autofluorescence bronchoscopy(AFB) is one of the newly developed diagnostic tools to detect the pre-cancerous lesions m the bronchial tissue. Several studies have shown that AFB improved the rate of detection of cancer and dysplastic lesions of the airway, especially those in intraepithelial stage. However, there were high rates of false positive with AFB, and it is also important to develop non-biopsy methods because of lack of accurate information of variable course of preneoplastic lesions regarding progression. So, many other technologies were developed, such as narrow band imaging(NBI), endobronchoscopic ultrasound, optical coherence tomography, and confocal fluorescence microendoscopy. Among the new machines, NBI is a new optical technology that can clearly visualize the microvascular structure m the mucosal layer. NBI seems to increase specificity without compromising sensitivity. In the future such techniques would make it possible to precisely study in detail the natural history of the premalignant epithelium.

  • PDF