• Title/Summary/Keyword: Ultrasound technology

Search Result 495, Processing Time 0.034 seconds

Development of Various Pilot Scale's Ultrasound Systems and Sonodegradation of Naphthalene in Water (다양한 형태의 Pilot Scale 초음파 시스템 개발 및 나프탈렌 분해효율 검증)

  • Park, Jong-Sung;Lee, Ha-Yun;Han, Jong-Hun;Her, Nam-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.281-288
    • /
    • 2011
  • Recently, researches that a variety of contaminants in water are removed by sonolysis technology with oxidation and pyrolysis process from cavitation were conducted. However, there are few studies for sonochemical treatment by a pilot-scale ultrasound system. This research focused on developing pilot-scale ultrasound systems, which could be an continuously effective treatment for a large volumes of contaminants, and demonstrating the feasibility of utilizing these systems to remove naphthalene from groundwater. V-120 type reactor was found to be 1.4~2.2 times higher effective than the normal type. A total of three different pilot scale's systems consisted of installing effluent and irrigation water in order to be a continuos system, including supplemental additives, and applying a V-120 type reactor and a external cooling cycle system. Naphthalene levels treated by three systems were lower than a recommended guideline of naphthalene for drinking water in EPA. Especially, the naphthalene removal efficiencies of PS1 and PS2 systems were over 97%. The pilot-scale continuous ultrasound clean-up system delivered over 84~95% naphthalene removal efficiency for treatment of 10~20 liter of groundwater. In addition, the ultrasound system could be successfully applied to the conditions of artificial and genuine groundwater contaminated with naphthalene.

Analysis of Liver Elasticity according to Ultrasound Findings (초음파 소견에 따른 간 탄성도 분석)

  • Chun, Hye-Ri;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • This study was conducted on 101 patients who visited hospital for abdominal ultrasonography from May 2020 to December 2020. The purpose of this study was to find out the elasticity according to the ultrasound images (echo pattern, splenomegaly, hepatitis) during the ultrasound examination using the shear wave elastography. The shear wave elastography value of the normal group of the echo pattern was 5.75±1.58 kPa, and the group with the abnormal echo pattern was 8.84±4.94 kPa, and the shear wave elastography value of the abnormal group was high (p<0.05). In normal spleen size, hepatic elasticity value was 6.33±2.54 kPa, and hepatic elasticity value of splenomegaly was 13.73±5.48 kPa. In the case of splenomegaly, the liver elasticity value was high, and there was a statistically significant difference (p<0.05). As the spleen size increased, the liver elasticity value increased by 1.485 times, and as hepatitis progressed, the liver elasticity value increased by 1.573 times (p<0.05). As a result of analysis of concordance between ultrasound imaging findings and shear wave elastography, the Kappa value was found to be as high as 0.922 (p<0.05), which showed high concordance between the two test methods. Additional comparisons of liver elasticity values in shearwave elastography tests along with liver ultrasound findings are thought to be of great help in diagnosing liver fibrosis.

Clinical Application of Focused Ultrasound in Korean Medicine (집속초음파 치료의 한의 임상 활용에 대한 고찰)

  • Yoomin Choi;Maeum Lee;Nayeon Hur;Eunhee Lee;Hyugyong Choi;Hyung-Sik Seo;Eui-Hyoung Hwang;Insoo Jang
    • Korean Journal of Acupuncture
    • /
    • v.40 no.3
    • /
    • pp.79-89
    • /
    • 2023
  • Objectives : The purpose of this study is to investigate various application methods of focused ultrasound and apply them to clinical use in Korean medicine. Methods : Search was performed using the search engines of electronic databases, including PubMed, ScienceDirect, Cumulative Index to Nursing and Allied Health Literature (CINAHL), ScienceON, Oriental Medicine Advanced Searching Integrated System (OASIS), China National Knowledge Infrastructure (CNKI), Wanfang Data, Japan Science Technology Information Aggregator, Electronic (J-STAGE) and Citation Information by NII (CiNii), from inception to July 2023 without language limitation. Inclusion criteria were clinical studies including randomized controlled trials (RCTs), and animal experimental studies related with focused ultrasound treatments for acupoints or meridian sinews. Results : Total 17 papers, 7 for RCT, 6 for in vivo animal studies, and other experimental studies, were finally selected. Indications used in studies were shoulder pain, back pain, chronic back pain, and degenerative knee arthritis. In experimental studies, studies on animal models of hypoxic ischemic brain damage and hyperlipidemia were also conducted. As for the acupoints, LR3, LI4, and ST36 were used in clinical studies and, in animal experimental studies, GV20, KI1, and ST36 were used. As for the dose, 4 studies below 3 W/cm2 and 3 studies in the range of 0.625 to 5 W/cm2 in clinical studies, and all studies did not exceed 5 W/cm2. In animal experimental studies, 0.5 W/cm2, 2 W/cm2, 7.5 WW/cm2, 15 W/cm2, 10~20 W/cm2 were used. In all three studies describing the penetration depth during irradiation, it was less than 1 cm. Conclusions : We suggest that focused ultrasound is an appropriate treatment tool for stimulating the acupoints to transfer heat energy. Future studies with rigorous and well-designed RCTs for various diseases will be required to ascertain the focused ultrasound stimulate acupoints or meridian sinews.

Improving the Microbial Safety of Fresh-Cut Endive with a Combined Treatment of Cinnamon Leaf Oil Emulsion Containing Cationic Surfactants and Ultrasound

  • Park, Jun-Beom;Kang, Ji-Hoon;Song, Kyung Bin
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.4
    • /
    • pp.503-509
    • /
    • 2018
  • Endive is widely consumed in a fresh-cut form owing to its rich nutritional content. However, fresh-cut vegetables are susceptible to contamination by pathogenic bacteria. This study investigated the antibacterial activities of the combined treatment of cinnamon leaf oil emulsion containing cetylpyridinium chloride or benzalkonium chloride (CLC and CLB, respectively) as a cationic surfactant and ultrasound (US) against Listeria monocytogenes and Escherichia coli O157:H7 on endive. The combined treatment of CLC or CLB with US reduced the population of L. monocytogenes by 1.58 and 1.47 log colony forming units (CFU)/g, respectively, and that of E. coli O157:H7 by 1.60 and 1.46 log CFU/g, respectively, as compared with water washing treatment. The reduction levels of both pathogens were higher than those observed with 0.2 mg/ml sodium hypochlorite. In addition, the combined treatment showed no effect on the quality of the fresh-cut endive (FCE). In particular, the degree of browning in FCE was less for the treatment group than for the control and water washing treatment groups. Thus, cationic surfactant-based cinnamon leaf oil emulsions combined with US may be an effective washing treatment for the microbial safety of FCE.

Synthesis of Nano-Scale Photocatalyic TiO2 Powder Doped with Ag by Sonochemistry Reaction (초음파화학 반응에 의한 Ag 도핑 광촉매용 나노 TiO2 분말의 합성)

  • Cho, Sung-Hun;Lee, Soo-Whon
    • Korean Journal of Materials Research
    • /
    • v.19 no.3
    • /
    • pp.169-173
    • /
    • 2009
  • In chemistry, the study of sonochemistry is concerned with understanding the effect of sonic waves and wave properties on chemical systems. In the area of chemical kinetics, it has been observed that ultrasound can greatly enhance chemical reactivity in a number of systems by as much as a million-fold. Nano-technology is a super microscopic technology in which structures of 100 nanometers or smaller can be investigated. This technology has been used to develop $TiO_2$ materials and $TiO_2$ devices of that size. Thus far, electrochemistry methods and photochemistry methods have generally been used to create $TiO_2$ nano-size particles. However, these methods are complicated and create pollutants as a by-product. In the present study, nano-scale silver particles (5 nm) were prepared in a sonochemistry method. Sonochemistry deals with mechanical energy that is provided by the collapse of cavitation bubbles that form in solutions during exposure to ultrasound. $TiO_2$ powders 25 nm in size doped with Ag were formed using an ultrasonic sound technique. The experimental results showed the high possibility of removing pollution through the action of a photocatalyst. This powder synthesis technique can be considered as an environmentally friendly powder-forming processing owing to its energy saving characteristics.

Harmonic Ultrasound Images and Conventional Ultrasound for Focal Hepatic Lesions: Comparison of Classification Performance by Computer-aided Diagnosis System (국소간병변의 하모닉 초음파와 고식적 초음파영상: 컴퓨터진단시스템에 의한 분류성능 비교)

  • Lee, Jae Young;Jo, In A;Lee, Sihyoung;Kim, Kyung Won;Ro, Yong Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.672-675
    • /
    • 2010
  • 초음파 영상은 다른 의료 진단 방법에 비해 상대적으로 비용이 적게 들고 데이터 획득이 용이하기 때문에 널리 이용되고 있다. 초음파 영상은 획득 방법에 따라 화질이 차이가 난다. 고식적 초음파 영상에 비해 두 배의 주파수를 사용하는 하모닉 영상은 대조도나 해상도가 향상되고, 영상 내 잡음이 감소한다. 그래서 초음파 영상을 이용한 진단 과정에서 병변의 특징을 육안으로 정확하게 관찰할 수 있고, 이를 통해서 진단 결과의 정확성이 향상된다. 본 논문에서는 초음파 영상의 획득 방법의 차이에 따른 진단 성능의 차이를 컴퓨터를 이용한 병변 분류 성능을 통해서 비교했다. 이를 위해서 초음파를 통해서 획득한 영상에서 병변의 형태 및 질감 특징을 추출하고, 이를 바탕으로 병변을 분류하는 시스템 구성하였다. 실험을 통해서 하모닉 초음파 영상을 이용한 컴퓨터 기반 분류 방법이 고식적 초음파를 이용한 방법에 비해서 6% 정확성 향상이 있는 것을 확인하였다.

Prediction of Carcass Meat Quality Grade by Ultrasound in Hanwoo (초음파를 이용한 한우의 도체육질 예측)

  • Rhee, Y.J.;Kim, J.Y.;Lee, S.K.;Song, Y.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.1095-1100
    • /
    • 2005
  • For the establishment of prediction strategies of carcass meat quality grade and for the enhancement of prediction accuracy, sixty six Hanwoo steers were ultrasonically tested at 24 months of age. Ultrasonic meat quality grade were predicted by standard ultrasonic image and decision tree method using ultrasonic meat quality index. From the results of decision tree method using ultrasonic meat quality index, it was found that the marbling score was mainly influenced by the distinctness of rib on ultrasound image. Prediction accuracy of meat quality grade by ultrasonic meat quality index was 86.4%, resulting in 7.6% higher accuracy than that by standard ultrasonic image (78.8%).

Optimization of ultrasound-assisted extraction of anthocyanins and phenolic compounds from campbell early grape using response surface methodology (반응표면분석법을 이용한 캠벨얼리 포도의 총 안토시아닌과 총 페놀의 초음파 추출조건 최적화)

  • Ryu, Dayeon;Koh, Eunmi
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.5
    • /
    • pp.474-479
    • /
    • 2018
  • In this study, ultrasound-assisted extraction conditions of total anthocyanins and total phenolic compounds from Campbell early grape (Vitis labruscana) were optimized via response surface methodology using a Box-Behnken design. Three independent variables, including solid-liquid ratio (1/30-1/50 g/mL), extraction time (2-10 min), and amplitude (20-100%), significantly affected total anthocyanin content. However, no significant effect of these variables was observed in the total phenolic compound content. The optimized extraction conditions were solid-liquid ratio of 1/48.13 g/mL, extraction time of 2 min, and amplitude of 20%. Under these conditions, the predicted values of total anthocyanins and total phenolic compounds were 94.96 and 1,661.16 mg/100 g dry weight (DW), respectively. The experimental values of total anthocyanins and total phenolic compounds were 88.25 and 1,554.37 mg/100 g DW, respectively, which is well matched with the predicted values within 7.5% difference.

Characterization of Elastic Modulus of Kelvin Foam Using Elastic Structural Model and Ultrasound (초음파와 탄성 구조 모델을 이용한 캘빈 폼 재료의 탄성계수 평가)

  • Kim, Woochan Ethan;Kim, Nohyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.474-482
    • /
    • 2016
  • A Kelvin foam plate - widely used in the energy and transport industries as a lightweight structural material - was examined to estimate its Young's modulus using ultrasound. An isotropic tetrakaidecahedron foam structure was designed in SolidWorks and printed using 3D printer with an ABS plastic material. The 3D printed foam structure was used to build a foam plate with a 14 mm thickness ($50mm{\times}100mm$ in size) for the ultrasonic test. The Kelvin foam plate, a significantly porous medium, was completely filled with paraffin wax to enable the ultrasound to penetrate through the porous medium. The acoustic wave velocity of the wax-filled Kelvin foam was measured using the time of flight (TOF) method. Furthermore, the elastic modulus of the Kelvin foam was estimated based on an elastic structural model developed in this study. The Young's modulus of the produced Kelvin foam was observed to be approximately 3.4% of the bulk value of the constituent material (ABS plastic). This finding is consistent with experimental and theoretical results reported by previous studies.

Evaluation of Waist Circumference Cut-off Values as a Marker for Fatty Liver among Japanese Workers

  • Abe, Naomi;Honda, Sumihisa;Jahng, Doosub
    • Safety and Health at Work
    • /
    • v.3 no.4
    • /
    • pp.287-293
    • /
    • 2012
  • Objectives: Metabolic syndrome has received attention as a risk factor for cardiovascular disease, with particular importance attached to visceral fat accumulation, which is associated with lifestyle-related diseases and is strongly correlated with waist circumference. In this study, our aim is to propose waist circumference cut-off values that can be used as a marker for fatty liver based on a sample of workers receiving health checkups in Japan. Methods: This study was conducted in a total of 21,866 workers who underwent periodic health checkups between January 2007 and December 2007. The mean age of the subjects was 47.4 years for men (standard deviation [SD]: 8.0) and 44.7 years for women (SD: 6.9). Evaluation included abdominal ultrasound and measurement of waist circumference, body mass index, fasting blood glucose, triglycerides, high-density lipoprotein cholesterol, and blood pressure. Results: Based on receiver operating characteristic curve analysis, the optimal waist circumference cut-off values were shown as 85.0 cm (sensitivity 0.72, specificity 0.69) for men and 80.0 cm (sensitivity 0.75, specificity 0.78) for women. Conclusion: Abdominal ultrasound is the most efficient means of diagnosing fatty liver, but this examination seldom occurs because the test is not routinely performed at workers' health checkups. In people found to have a high risk of fatty liver, recommendations can be made for abdominal ultrasound based on the waist circumference cut-off values obtained in this study. That is, waist circumference can be used in high risk individuals as an effective marker for early detection of fatty liver.