• Title/Summary/Keyword: Ultrasound technology

Search Result 495, Processing Time 0.03 seconds

Prediction of Carcass Yield by Ultrasound in Hanwoo (초음파 측정에 의한 한우의 도체육량 예측)

  • Rhee, Y. J.;Jeon, K. J.;Choi, S. B.;Seok, H. K.;Kim, S. J.;Lee, S. K.;Song, Y. H.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.335-342
    • /
    • 2003
  • This study was conducted to predict the carcass yield traits using ultrasound before slaughter and to enhance the prediction accuracy of carcass yield grade by applying various strategies. For this experiment, five hundred seventy three Hanwoo steers of 24 months of age were used. Difference between ultrasound result and carcass measure of BFT and LMA was 0.6$\pm$1.65mm and 0.7$\pm$5.56cm2, respectively. Correlation coefficient between ultrasound result and carcass measure of BFT and LMA was 0.86 and 0.82, respectively (p<0.001). Results for improving predictions of yield grade by four methods-the Korean yield grade index equation, fat depth alone, regression and decision tree methods were 80.3%, 81.3%, 80.1% and 81.8%, respectively. We conclude that the decision tree method can easily predict yield grade and is also useful for increasing prediction accuracy rate.

An Benefit-cost Analysis of the Cleaning Device for Photovoltaic Power Generation Systems in Buildings (건축물에 설치된 태양광발전설비를 위한 세척장치의 편익-비용 분석)

  • Kim, Jae-Yeob;Won, Jongsung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.587-594
    • /
    • 2016
  • This study aims to analyze the benefit-cost of the cleaning device for photovoltaic power generation systems in buildings in order to check its economic feasibility. A product, which has similar characteristics to the ultrasound-based cleaning device and is widely used in South Korea, was selected to compare with the benefit-cost value of the ultrasound-based cleaning device in this study. In order to quantitatively and qualitatively analyze benefit and cost aspects of the two products, categories and evaluation factors of each aspect as well as evaluation criteria were identified. Based on the identified evaluation factors and criteria, this study conducted face-to-face interviews with 15 experts to measure weights of benefit and cost aspects of the products. As the results, the total benefit weight of the ultrasound-based cleaning device was larger than its total cost weight since the benefit-cost value was greater than 1, which was 1.6 times of that of to compared product. Therefore, from the economic perspective, it is worth to develop the cleaning device for photovoltaic power generation systems applying ultrasound technology.

Analysis of Hospital Infection Control Awareness of Ultrasound Room Office Personnel in Busan (부산지역 초음파실 근무인원의 병원감염관리 인식 분석)

  • Kim, Jung-Hoon;Kang, Se-Sik;Kim, Chang-soo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.135-143
    • /
    • 2015
  • 146 people working in the ultrasound room in Busan were surveyed, and their perception of hospital infection was analyzed. According to the results of the survey, academic background showed the highest number in terms of awareness and performance of personal hygiene management and hand washing management, and the group with experience of infection education showed the highest number in terms of awareness of ultrasound equipment hygiene, and the group with less than college education showed the highest number in terms of performance of ultrasound equipment hygiene. The difference was statistically significant. Based on the results of this study, performance was lower than awareness in general. This result indicates that the degree of performance is inadequate. Therefore, it can be concluded that individuals need to change their perception of personal hygiene and take interest in it through infection education.

Isotherm, kinetic and thermodynamic studies of dye removal from wastewater solution using leach waste materials

  • DEN, Muhammed Kamil O;ONGAR, Sezen KUC UKC
    • Advances in environmental research
    • /
    • v.8 no.1
    • /
    • pp.23-38
    • /
    • 2019
  • In this study, Malachite Green (MG) dye removal from synthetic wastewaters by adsorption process using raw boron enrichment waste (BEW) and it's modifications (with acid and ultrasound) were aimed. 81% MG removal was obtained by BEW at optimum equilibrium conditions (time: 40 min., dosage: 500 mg/dm3, pH: 5-6, speed: 200 rpm, 298 K). MG removal from wastewaters using acid modified boron enrichment waste (HBEW) was determined as 82% at optimum conditions (time: 20 min., dosage: 200 mg/dm3, pH: 10, speed: 200 rpm, 298 K). For ultrasound modified BEW (UBEW), the highest MG removal percent was achieved as 84% at optimum conditions (time: 30 min, dosage: 375 mg/ dm3, pH: 8, speed: 200 rpm, 298 K). The equilibrium data of Malachite Green was evaluated for BEW, HBEW and UBEW adsorbents by using sorption isotherms such as Langmuir, Freundlich and Temkin models, out of which Langmuir model (R2 = 0.971, 0.987 and 0.984) gave better correlation and maximum adsorption capacity was found to be 147.05, 434.78 and 192.30 mg/g, respectively. The adsorption kinetics followed the pseudo-second-order kinetic equation for sorption of MG onto wastes. A look at thermodynamic data reveals that natural sorption is spontaneous and endothermic because of free negative energy exchange and positive change in enthalpy, respectively. The results indicated that boron enrichment waste, and HCl and ultrasound-modified boron enrichment waste served as good alternative adsorbents in dye removal from wastewater.

DEFECT DETECTION WITHIN A PIPE USING ULTRASOUND EXCITED THERMOGRAPHY

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.637-646
    • /
    • 2007
  • An UET (ultrasound excited thermography) has been used for several years for a remote non-destructive testing in the automotive and aircraft industry. It provides a thermo sonic image for a defect detection. A thermograhy is based On a propagation and a reflection of a thermal wave, which is launched from the surface into the inspected sample by an absorption of a modulated radiation. For an energy deposition to a sample, the UET uses an ultrasound excited vibration energy as an internal heat source. In this paper the applicability of the UET for a realtime defect detection is described. Measurements were performed on two kinds of pipes made from a copper and a CFRP material. In the interior of the CFRP pipe (70mm diameter), a groove (width - 6mm, depth - 2.7mm, and length - 70mm) was engraved by a milling. In the case of the copper pipe, a defect was made with a groove (width - 2mm, depth - 1mm, and length - 110 mm) by the same method. An ultrasonic vibration energy of a pulsed type is injected into the exterior side of the pipe. A hot spot, which is a small area around the defect was considerably heated up when compared to the other intact areas, was observed. A test On a damaged copper pipe produced a thermo sonic image, which was an excellent image contrast when compared to a CFRP pipe. Test on a CFRP pipe with a subsurface defect revealed a thermo sonic image at the groove position which was a relatively weak contrast.

Classification Algorithm for Liver Lesions of Ultrasound Images using Ensemble Deep Learning (앙상블 딥러닝을 이용한 초음파 영상의 간병변증 분류 알고리즘)

  • Cho, Young-Bok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.101-106
    • /
    • 2020
  • In the current medical field, ultrasound diagnosis can be said to be the same as a stethoscope in the past. However, due to the nature of ultrasound, it has the disadvantage that the prediction of results is uncertain depending on the skill level of the examiner. Therefore, this paper aims to improve the accuracy of liver lesion detection during ultrasound examination based on deep learning technology to solve this problem. In the proposed paper, we compared the accuracy of lesion classification using a CNN model and an ensemble model. As a result of the experiment, it was confirmed that the classification accuracy in the CNN model averaged 82.33% and the ensemble model averaged 89.9%, about 7% higher. Also, it was confirmed that the ensemble model was 0.97 in the average ROC curve, which is about 0.4 higher than the CNN model.

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

Effects of Moisture Content in Concrete on Diffuse Ultrasound (확산초음파의 콘크리트 함수율에 대한 의존성)

  • Ahn, Eunjong;Shin, Myoungsu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.142-147
    • /
    • 2020
  • This study investigates the effects of moisture content on diffuse ultrasound to be applied for the evaluation of micro-structural damage in concrete subjected to various environmental conditions. We monitored diffuse wave parameters for concrete samples in process of water saturation for 5 days. Dried samples were immersed in a water bath, and the change of moisture content in concrete were estimated by measuring the change of mass. For the diffuse wave analysis, a frequency range of 500 kHz, which represents a scattering regime of ultrasound in concrete, was selected. The test results reveal that the ultrasonic diffusivity slightly changed, and the ultrasonic dissipation significantly increased by approximately 120% in the process of water saturation. Therefore, the moisture content in concrete should be considered for the evaluation of micro-structural damage using diffuse wave techniques.

Comparative Evaluation of Filters for Speckle Noise Reduction in a Clinical Liver Ultrasound Image (간 초음파 영상에서의 스페클 노이즈 제거를 위한 필터들의 비교 평가)

  • Hajin Kim;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.475-484
    • /
    • 2023
  • This study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the filter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.

Enhanced Transdermal Delivery of Procaine Hydrochloride by lontophoresis -Comparison of Synergic Effect of High Voltage Current and Ultrasound- (이온도입에 의한 염산프로카인의 경피전달 증대 -고전압전류 및 초음파 병행의 상승효과 비교-)

  • Lee, Jong-Sook;Kim, Kyoung-Won;Lee, Jae-Hyoung;Choi, Yeong-Wook;Lee, Jae-Hwi
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.185-192
    • /
    • 2006
  • The purpose of this study was to determine the effects of iontophoresis on transdermal delivery of procaine hydrochloride in healthy volunteers, as well as to the synergic effect of high voltage current or ultrasound on the efficacy of transdermal delivery of iontophoresis. Forty healthy volunteers were randomly assigned to four groups topical application group (TA), iontophoresis group (IT), pre-treatment of high voltage current stimulation with iontophoresis (HVS + IT), and pre-treatment of ultrasound application with iontophoresis (US + IT). All subjects received procaine iontophoresis on the forearm using direct current with 4 mA f3r 15 minutes. All subject was measured the duration of local anesthesia, pressure pain threshold, pain perception threshold using rectangular wave at 0.2 ms, 1 ms, 50 ms of rectangular current stimulation after procaine iontophoresis. For comparisons of the sensory characteristics and efficacy of iontophoresis between the groups, an one-way ANOVA and Kruskal-Wallis were used. The significant difference the duration of local anesthesia were found between the groups (p<0.001). The local anesthetic duration of IT, HVS+IT were significantly longer than TA. Meanwhile, the local anesthetic duration of US+IT was significantly longer than HVS+IT, IT and TA group (p<0.05). Also, the pressure pain threshold, pain perception threshold at 0.2 ms, 1 ms, 50 ms were significant difference between the groups (p<0.001). All sensory characteristics including pressure pain threshold, pain perception threshold of IT, HVS+IT was significantly increased than TA, whereas, US+1T was significantly increased HVS+1T, IT and TA (p<0.05). This study showed that the procaine iontophoresis have increase the duration of local anesthesia concomitantly pressure pain threshold and pain perception threshold of sensory nerve fibers such as $A-{\beta}$, $A-{\delta}$ and C fiber. This findings suggest that the iontophoresis enhanced the transdermal delivery of drug ions in vivo. The combination of ultrasound application and iontophoresis synergized the transdermal delivery of drug ions. It is suggests that an electric field, mechanical and heating property of ultrasound may contribute to synergic effect due to temporary changes of structure in the stratum corneum.