• Title/Summary/Keyword: Ultrasound measurement

Search Result 328, Processing Time 0.027 seconds

A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity (초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구)

  • Kim, S.M.;Lee, M.P.;Choi, B.C.;Choi, S.H.;Bae, H.S.;Jung, H.S.;Park, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF

Accuracy of Ultrasonography in Early Pregnancy Diagnosis in Doe

  • Singh, N.S.;Gawande, P.G.;Mishra, O.P.;Nema, R.K.;Mishra, U.K.;Singh, Mohan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.6
    • /
    • pp.760-768
    • /
    • 2004
  • The present study was undertaken to evaluate the accuracy of ultrasonography in early pregnancy diagnosis in goats. Ultrasonographic scanning with real time B-mode ultrasound machine having 5 MHz linear array transducer was performed on gravid uterus (n=24) obtained from slaughterhouse (Group I). Crown rump length (CRL) measured by ultrasound was found significantly different (p<0.05) with actual CRL measured after dissection in early pregnancy. However, age predicted by ultrasound through the measurement of CRL was found highly correlated (r=0.92) with age measured after dissection through CRL and the weight of fetus. Ages predicted by ultrasound through the measurement of trunk diameter (TD) and uterine diameter (UD) and ages measured after dissection were found highly and equally correlated (r=0.98) and did not differ significantly. Data from six does synchronized (Group II) with PGF2$\alpha$ (Estrumate) at 11 days apart were collected through ultrasound from 17 to 42 days post breding. The correlation between CRL and gestational age was high (r=0.97) in day 30 to 42 post breeding. A high coefficient of correlation (r=0.98) was also observed between predicated age by ultrasound and actual age calculated after kidding. The correlation between CRL and gestational age by the formula Y=(a+bX) i.e. Y=24.42+0.39 X where Y=gestational age and X=CRL, was recorded very high (r=0.99). Accuracy of ultrasonography was lowest on day 17 to 19 (66%) and reached 100% on day 34. Data from 30 does (group III) randomly subjected to only one time ultrasounds scanning to assess the accuracy of pregnancy diagnosis were also obtained. Ages predicted by TD and UD measurements were observed to be non-significantly different with actual age obtained after kidding and correlation between ages predicted by TD and UD measurement with actual age after kidding was found equally and highly correlated (r=0.98). The operator's accuracy in the whole experiment including all three groups was found to be 92%. The sensitivity was 93% and specificity was 86%. From the present study, it was observed that CRL was the most reliable parameter to find out gestational age in early pregnancy and the new formula derived was found very accurate to find out gestational age. TD and UD were also found to be equally reliable parameter to find out gestational age in mid and late stage of pregnancy through ultrasonography. It was concluded that ultrasonography by real time B mode with 5 MHz transrectal transducer was found to be reliable, safe and accurate and practicable means in diagnosing early pregnancy diagnosis as early as 25 days post breeding.

Reliability study of the Pectoralis Minor Muscle Thickness Measurement using Rehabilitative Ultrasound Imaging

  • Lim, Ji Young;Lee, Se-Yeong;Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2021
  • PURPOSE: This study examined the imaging procedure of pectoralis minor muscle thickness and assessed the intra- and inter-rater reliability of the muscle thickness measured by two raters using rehabilitative ultrasound imaging (RUSI) in healthy individuals. METHODS: Fifteen participants (aged 21 - 28, seven females, and eight males) were involved in the study. The primary rater palpated the coracoid process and the fourth rib, defined as the width of the index finger lateral to the sternum to avoid breast tissues, and lined the two landmarks. The second examiner checked 1 / 3 (1st point) and 1 / 2 (2nd point) of the line length as measurement points. The two raters obtained right side muscle images of the participants at a standardized sitting position using RUSI with a 7.5 MHz linear transducer at 40mm depth. For intra-rater reliability, the principal rater took three images per point and tried to take one more with an interval. For the inter-rater reliability, the other rater performed the same tasks as the principal rater on the same day. The reliability was analyzed using the intra-class correlation coefficient (ICC), the standard error of the measurement (SEM), and Bland and Altman plots. RESULTS: The reliability at all points was excellent for the same rater (ICC3,1 = .973 - .978, SEM = .042 - .046), and between raters (ICC2,1 = .939 - .959, SEM = .059 - .097). CONCLUSION: These findings show that the RUSI could be reliable for examining the pectoralis minor muscle thickness in healthy individuals at all measurement sites.

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.

A Basic Study on the Variation of Temperature Characteristics for Attenuation Coefficient and Sound Velocity in Biological Tissues

  • Park, Heung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.273-282
    • /
    • 1993
  • This study is concerned with the temperature dependence characteristics of ultrasound parameters in biological tissues, which are basic on the noninvasive deep body temperature estimation. Used parameters are ultrasonic attenuation coefficient and sound velocity In order to accomplishment our purpose, several signal processing methods were used. Attenua4iorl coefficient was estimated by spectral difference method and sound velocity was estimated by P-P method. And we also examined these methods through a series of IN VITRO experi mentis that used tissue-mimicking phantom samples and biological tissue samples. In order to imitate the biological soft tissue two kinds of phantom samples are used, one is agar phantom sample which is composed of agar, graphite, N-propyl alcohol and distilled water, and the other is fat phantom sample which is composed of pure animal fat. And the ultrasound transmission mode and reflection mode experiments are performed on the pig's spleen, kidney and fat. As a result, it is found that the temperature characteristics are uniform in case of phan- tom samples but not in biological tissues because of complicate wave propagation within them. Consequently, the possibility of temperature measurement using ultrasound on biological tissue is confirmed and its results may contribute to the establishment of reference values of internal temperature measurement of biological tissues.

  • PDF

A Study for burning behavior of Hydro-Reactive metal fuel using Ultrasound (초음파를 이용한 해수반응 연료의 연소거동 고찰 연구)

  • Seo, Mu-Kyung;Kang, To;Cho, Seung-Wan;Kim, Hak-Joon;Song, Sung-Jin;Kim, Jun-Hyung;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.451-454
    • /
    • 2011
  • Hydro-Reactive metal Fuel (HRF) which has more fuel than general solid propellant reducing oxidizing agent is suitable for ultrahigh speed rocket motor in the water. However, burning rate of HRF has not been studied yet. Through the earlier studies, we established ultrasonics measurement system measuring burning rate of solid propellant as a function of pressure in a single test and verified its reliability. In this paper, we will measure burning rate of HRF using ultrasound with previous development measurement system.

  • PDF

Measurement and Clinical Analysis of Carotid Intima, Media and Intima-Media Thickness

  • Kim, Wuon-Shik;Jeong, Hwan-Taek;Bae, Jang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.1
    • /
    • pp.6-13
    • /
    • 2005
  • Individual clinical significance of each layer of CCA (common carotid artery) has not been well studied. We intended to measure the intima thickness (IT), media thickness (MT), and intima-media thickness (IMT) of CCA separately and tried to analyze the clinical significance. One hundred fifty one consecutive patients (mean age: $57{\pm}15$ years; 77 males, 74 females) underwent CCA scanning using high-resolution ultrasound. The images were off-line analyzed using B-mode ultrasound image processing, devised for individual measurement of IT and MT as well as IMT. The mean coefficients of variation of new method measuring IT, MT, and IMT separately were 0.16% for IMT and 0.21% for both IT and MT. The IT (p < 0.01), MT (p < 0.01) as well as IMT (p < 0.001) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hypertension showed significantly thicker IT (p < 0.01), MT (p < 0.001), and IMT (p < 0.001) than that of the patients without hypertension. However, only IT was thicker in patients with smoking (p<0.01) than that of the patients without smoking.

  • PDF

Burning Rate Testing of Double Base Solid Propellants using Ultrasound (초음파를 이용한 Double Base형 고체추진제의 연소속도 측정)

  • Song, Sung-Jin;Ko, Sun-Feel;Kim, Hak-Joon;Oh, Hyun-Taek;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.247-250
    • /
    • 2006
  • In the previous study, we have developed an ultrasonic measurement system and analysis technique for borning rate testing of solid propellants using ultrasound. And then, using the developed system, burning rate of composite propellants were measured. So, in this study, we performed measurement of double base solid propellant, which has non-linear homing rate as pressure increasing, using the developed system in order to evaluate capability of ultrasonic method. Furthermore, accuracy of measured homing rates using ultrasound was verified by comparison to homing rate measured by the strand burner method.

  • PDF