• Title/Summary/Keyword: Ultrasound measurement

Search Result 328, Processing Time 0.023 seconds

Comparison of the Thickness of the Neck Flexor Between Open and Closed Kinetic Chain Exercises During Chin-in Movement (슬링을 이용한 열린사슬운동과 닫힌 사슬 운동의 턱당기기 동작 시 목굽힘근 두께 비교)

  • Lee, Ju-Hun;Han, Jin-Tae
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.333-341
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the effect of open and closed kinetic chain exercises with a sling on neck flexor thickness during chin-in movement in office workers with forward head posture. Methods: Thirty-one selected subjects randomly performed chin-in movement in open kinetic chain and closed kinetic chain exercises using a sling. All subjects were measured for their neck flexor thickness using ultrasound measurement equipment during the performance of chin-in movement in open and closed kinetic chain exercised. A paired t-test was used to compare the thickness of the total neck flexor, superficial, and deep neck flexor, respectively, between open and closed kinetic chain exercises with chin-in movement. Results: The thickness of the superficial neck flexor diminished in size more greatly during the chin-in movement with the closed kinetic chain than the open kinetic chain, but this was not a statistically significant difference (p > 0.05). On the other hand, the thickness of the total neck flexor and deep neck flexor had more greatly increased during the chin-in movement with the closed kinetic chain than the open kinetic chain, and this was a statistically significant differences (p < 0.05). Conclusion: This study suggested that chin-in movement with a closed kinetic chain is more effective in activating the deep neck flexor than the open kinetic chain. Thus, we believe that the closed kinetic chain exercise using a sling is an effective intervention to correct the postural alignment of individuals with forward head posture.

The Effect of the Contraction Pressure of the Hip Adductor Muscles on Thickness of Transversus Abdominis: A Randomized Controlled Trial (엉덩관절 모음근의 수축 압력이 배가로근의 근 단면적에 미치는 영향)

  • Ju-Cheol, Park;Myeong-Ho, Lee;Myoung-Kwon, Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.53-63
    • /
    • 2022
  • PURPOSE: This study examined the changes in the thickness of the abdominal muscles, including the transversus abdominis, according to the set pressure applied by a pressure biofeedback unit during contractions of the hip adductor muscles. METHODS: After randomizing 40 healthy adult males in their 20 s and 30 s, the participants were instructed to match the pressure gauge indication of the pressure biofeedback device to continue contracting the hip adductor while maintaining it at 10 mmHg (low), 40 mmHg (medium), or 70 mmHg (high). The measurement was taken over five seconds using an ultrasound device. RESULTS: According to the contractile pressure applied to the hip adductor muscle, there was a significant difference in the muscle thickness change of the transverse abdominis muscle between 10 mmHg and 70 mmHg and between 40 mmHg and 70 mmHg. The muscle thickness ratio of the external oblique/abdominal muscle was significantly different between 10 mmHg and 70 mmHg and between 40 mmHg and 70 mmHg. CONCLUSION: Increased contraction pressure on the hip adductor muscle increases the muscle thickness of the abdominal transverse muscle. Interbody stability exercise with contractions of the hip adductor muscle is expected to help increase in the muscle thickness of the hip adductor muscle.

Effects of Both Abdominal Drawing-In Maneuver and Co-Contraction of Hip Adductor Muscle while Bridge Exercise on Abdominal Muscle

  • Gyeong-Hui, Park;Jin-Hwa, Lee;You-Mi, Jung;Dongyeop, Lee;Ji-Heon, Hong;Jae-Ho, Yu;Jin-Seop, Kim;Seong-Gil, Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.15-25
    • /
    • 2022
  • PURPOSE: This study examined the effect of bridge exercise-abdominal draw-in maneuver (ADIM) with hip adductor co-contraction on the TrA thickness and whether it is effective as a core stability exercise. METHODS: The subjects of this study, 33 men with no history in the past and who provided prior consent, were selected through interviews with male students of S University. The subjects performed five movements, including bridge exercise and ADIM, and performed two demonstrations and two exercises in advance. The abdominal muscles were measured using ultrasonography once in each movement, and the abdominal muscle tone was measured using a soft tissue tone measurement. RESULTS: There was a significant difference in the thickness between the TrA and Internal Oblique Muscles at various bridge positions (p < .05), and no significant difference with the External Oblique Muscle (p < .05). There was no significant difference in muscle tone in the Rectus abdominis part (p > .05), but a significant difference in the Oblique Muscle part (p < .05). The muscle tone of the Oblique Muscles by position showed a significant difference in Bridge, BHa, and BA compared to the rest position (p < .05), but no significant difference with BHaA (p > .05). CONCLUSION: The thickness of TrA could be increased through bridge exercise, and TrA could be activated properly using ADIM and may be an effective exercise for core stabilization.

Comparison of the efficacy of genicular nerve phenol neurolysis and radiofrequency ablation for pain management in patients with knee osteoarthritis

  • Gokhan Yildiz;Gevher Rabia Genc Perdecioglu;Damla Yuruk;Ezgi Can;Omer Taylan Akkaya
    • The Korean Journal of Pain
    • /
    • v.36 no.4
    • /
    • pp.450-457
    • /
    • 2023
  • Background: Genicular nerve neurolysis with phenol and radiofrequency ablation (RFA) are two interventional techniques for treating chronic refractory knee osteoarthritis (KOA) pain. This study aimed to compare the efficacy and adverse effects of both techniques. Methods: Sixty-four patients responding to diagnostic blockade of the superior medial, superior lateral, and inferior medial genicular nerve under ultrasound guidance were randomly divided into two groups: Group P (2 mL phenol for each genicular nerve) and Group R (RFA 80℃ for 60 seconds for each genicular nerve). The numeric rating scale (NRS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were used to evaluate the effectiveness of the interventions. Results: RFA and phenol neurolysis of the genicular nerves provided effective analgesia within groups at 1 week, 1 month, and 3 months compared to baseline. There was no significant difference between the groups in terms of NRS and WOMAC scores at all measurement times. At the 3rd month follow-up, 50% or more pain relief was observed in 53.1% of patients in Group P and 50% of patients in Group R. The rate of transient paresthesia was 34.4% in Group P and 6.3% in Group R, and this was significantly higher in Group P. Conclusions: Neurolysis of the genicular nerves with both RFA and phenol is effective in the management of KOA pain. Phenol may be a good alternative to RFA. Further studies are needed on issues such as dose adjustment to prevent transient paresthesia response.

Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives (국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로)

  • Juchul Kim;Byoungcheun Hwang;Manki Hwang;Seungmin Kathy Lee;EunHee Yi;Jungtae Leem
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

Measurement of atherosclerosis markers in individuals with periodontitis

  • Angar Soronzonbold;Erkhbilguun Munkhkherlen;Khongorzul Batchuluun;Oyun-Enkh Puntsag;Uurtuya Shuumarjav;Bayarchimeg Batbayar
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.37-43
    • /
    • 2024
  • Purpose: The inflammatory response due to inflammatory cytokines, bacterial pathogens, and the altered lipoprotein metabolism in patients with periodontitis indicates that infection with periodontal anaerobic bacteria may influence atherogenesis in vitro and in vivo. We aimed to explore the effect of periodontitis concerning clinical and ultrasound markers of early atherosclerosis. Methods: In this case-control study, a total of 30 systemically healthy adults (15 with periodontitis and 15 without periodontitis) over 40 years of age were studied. Periodontitis was determined by measuring the clinical attachment level (CAL) and radiographic bone loss (RBL). Conventional cardiovascular risk factors, including body mass index, serum levels of total cholesterol (TCH), triglycerides (TG), and high-density and low-density lipoprotein (HDL and LDL, respectively) cholesterol were evaluated. Carotid artery intima-media thickness (IMT) was measured using ultrasonography. Results: The mean values of the CAL and carotid IMT were 5.02±0.9 mm and 0.084±0.01 cm vs. 1.6±0.61 mm and 0.072±0.02 cm in the periodontitis and healthy groups, respectively, reflecting statistically significant differences (P=0.001 and P=0.037, respectively). There were statistically significant differences in the serum levels of TCH, TG, and LDL between the 2 groups (P=0.017). The CAL and RBL were positively associated with carotid IMT and serum cholesterol levels, except for HDL, whereas tooth loss was not associated with any markers (P<0.05). Compared to the healthy group, participants with periodontitis exhibited 2.09 times higher odds (95% confidence interval, 1.22-3.59) of having subclinical atherosclerosis. Conclusions: The presence of periodontitis increased the risk of atherosclerosis.

Effects of Draw-In Bridge Exercise with Taping or Visual Feedback on Abdominal Muscle Activity (테이핑 또는 시각적 피드백을 병행한 드로우-인 교각운동이 복부 근활성도에 미치는 영향)

  • Won-Sik Bae;Hwa-Gyeong Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.177-186
    • /
    • 2024
  • Purpose : The purpose of this study was to use oral instruction and taping to induce abdominal draw-in in the previous study, but there is a lack of research on the comparison of effects. Therefore, in this study, we would like to study how the effect of oral instruction, taping, and no feedback can affect muscle activity when performing abdominal draw-in pier exercises. Methods : Before the experiment, group A trained piers and applied only draw-in piers, group B applied taping feedback, and group C were divided into three groups per week for six weeks, and three sets of contractions for five seconds per group were performed five times, and a minute break was provided between each exercise. As a measurement tool, a wireless surface electromyography (EMG) was used to measure surface electromyography (Telemyo-DTS, NORAXON, USA) that derives a synthetic unit of muscle using a surface electrode. For statistical processing of data, the analysis is performed using the SPSS/PC Version 25.0 statistical program for Windows, and the statistical significance level is a=.05 Results : First, the duration was somewhat shorter in order to more accurately compare the muscle activity of the core muscles. Therefore, future research needs to be research that can be exercises with precise biofeedback and taping applied over a longer period of time. Secondly, it is believed that there is no significant difference, since the subjects were studied in healthy young adult men and women, not patients. Thirdly, they could not control the daily life of the subjects. Through future research, it is necessary to analyze the correlation between muscle activity and abdominal muscle thickness by adding ultrasound in addition to muscle activity in various age groups. Conclusion : During draw-in bridge exercise according to feedback, the muscle activity of the back muscle increased, and there was no significant difference in the muscle activity of the back muscle according to each feedback. Therefore, both the feedback applied during the draw-in pier exercise and the control group are effective in changing the thickness of the abdominal muscles.

Prostate Volume Measurement by TRUS Using Heights Obtained by Transaxial and Midsagittal Scanning: Comparison with Specimen Volume Following Radical Prostatectomy

  • Sung Bin Park;Jae Kyun Kim;Sung Hoon Choi;Han Na Noh;Eun Kyung Ji;Kyoung Sik Cho
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.110-113
    • /
    • 2000
  • Objective: The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Materials and Methods: Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height × length × width × 𝜋/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Results: Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Conclusion: Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning.

  • PDF

New insight into the vasto-adductor membrane for safer adductor canal blockade

  • Yanguk Heo;Miyoung Yang;Sung Min Nam;Hyun Seung Lee;Yeon-Dong Kim;Hyung-Sun Won
    • The Korean Journal of Pain
    • /
    • v.37 no.2
    • /
    • pp.132-140
    • /
    • 2024
  • Background: This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB). Methods: Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume. Results: The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery. Conclusions: Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.