• 제목/요약/키워드: Ultrasound measurement

검색결과 328건 처리시간 0.024초

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

Genetic Relationship between Ultrasonic and Carcass Measurements for Meat Qualities in Korean Steers

  • Lee, D.H.;Kim, H.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권1호
    • /
    • pp.7-12
    • /
    • 2004
  • Real time ultrasonic measurements for 13th rib fat thickness (LBF), longissimus muscle area (LEMA) and marbling score (LMS) of live animal at pre-harvest and subsequent carcass measurements for fat thickness (BF), longissimus muscle area (EMA), marbling score (MS) as well as body weight of live animal, carcass weight (CW), dressing percentage (DP), and total merit index (TMI) on 755 Korean beef steers were analyzed to estimate genetic parameters. Data were analyzed using multivariate animal models with an EM-REML algorithm. Models included fixed effects for year-season of birth, location of birth, test station, age of dam, linear and quadratic covariates for age or body weight at slaughter and random animal and residual effects. The heritability estimates for LEMA, LBF and LMS on RTU scans were 0.17, 0.41 and 0.55 in the age-adjusted model (Model 1) and 0.20, 0.52 and 0.55 in the weight-adjusted model (Model 2), respectively. The Heritability estimates for subsequent traits on carcass measures were 0.20, 0.38 and 0.54 in Model 1 and 0.23, 0.46 and 0.55 in Model 2, respectively. Genetic correlation estimate between LEMA and EMA was 0.81 and 0.79 in Model 1 and Model 2, respectively. Genetic correlation estimate between LBF and BF were high as 0.97 in Model 1 and 0.98 in Model 2. Real time ultrasonic marbling score were highly genetically correlated to carcass MS of 0.89 in Model 1 and 0.92 in Model 2. These results indicate that RTU scans would be alterative to carcass measurement for genetic evaluation of meat quality in a designed progeny-testing program in Korean beef cattle.

후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정 (Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation)

  • 송성진;권성덕;정용무;김영환
    • 한국음향학회지
    • /
    • 제22권1호
    • /
    • pp.61-68
    • /
    • 2003
  • 유도초음파는 얇은 판재와 다층재료를 평가하는데 널리 사용되는데, 이를 정량적으로 이용하기 위해서는 위상 및 군속도의 분산 곡선은 필수적이다. 본 연구에서는 누수 램파의 후방복사 신호를 측정하기 위한 측정장치를 개발하였다. 시험편을 회전시켜서 입사각을 변화시켰으며, 2차원 평면에서 움직이면서 입사 위치를 바꾸었다. 광대역 초음파 탐촉자를 사용하여 탄성판에서 발생하는 누수 램파 후방복사 신호를 측정하였다. 입사각으로부터 위상속도가 결정되며, 이에 해당하는 램파의 특정모드가 판재 내에 강하게 발생되고, 이 램파는 시험편의 앞뒤로 진행하면서 물속으로 에너지를 방출한다. 동일한 탐촉자를 사용하여 누수 램파의 후방복사 신호를 검출하고, 이 신호의 주파수 성분은 분산곡선에 대한 정보를 지닌다. 입사각도와 수신된 파형의 주파수 분석을 통하여 램파의 위상속도 분산곡선을 구하였다. 또한 특정한 입사각에서 입사점을 변화시키면서 초음파 신호의 시간대역 이동으로부터 군속도를 측정하였다.

Shih-tzu견에서 초음파 검사에 의한 분만일 예시표 확립 (Establishment of a prediction table of parturition day in Shih-tzu bitches with ultrasound scanning)

  • 김방실;고진성;이순애;조양택;김재풍;오기석;김종택;박인철;김영홍;손창호
    • 대한수의학회지
    • /
    • 제44권2호
    • /
    • pp.303-310
    • /
    • 2004
  • To establish a prediction table of parturition day real-time B-mode ultrasonographic examinations were performed in 12 pregnant Shih-tzu bitches. Measurement of inner chorionic cavity diameter and fetal head diameter was performed from 15 days of gestation to parturition. These were converted retrospectively based on the day of parturition (Day 0). The data of inner chorionic cavity diameter obtained from Day -44 to Day -25 and fetal head diameter obtained from Day -25 to Day -1 were used to compile a prediction table of parturition day. The 22 pregnant Shih-tzu with unknown mating time were examined to assess an accuracy of the table established in this study. And these results were applied to the prediction of parturition day and compared to actual parturition day. Parturition day prediction based on the inner chorionic cavity diameter and fetal head diameter was 100% accurate within ${\pm}2$ days. In addition, the accuracy for parturition day within 0, ${\pm}1$, and ${\pm}2$ days interval using the prediction table of parturition day were 68, 82, and 100%, respectively. Therefore, the prediction table of parturition day seems to be a useful tool for the prediction of parturition day in practice.

농산물 및 경작지 토양 시료 중 Benzo(a)pyrene 신속잔류분석법 개선 연구 (A Study on Rapid Residual Analysis of Benzo(a)pyrene in Agricultural Products and Soils)

  • 김희곤;함헌주;홍경숙;신희창;허장현
    • 한국환경농학회지
    • /
    • 제39권1호
    • /
    • pp.44-49
    • /
    • 2020
  • BACKGROUND: Benzo(a)pyrene is a highly toxic substance which has been listed as a Group I carcinogen by the International Agency for Research on Cancer. There have been numerous studies by researchers worldwide on benzo(a)pyrene. Soxhlet, ultrasound-assisted, and liquid-liquid extractions have been widely used for the analysis of benzo(a)pyrene. However these extraction methods have significant drawbacks, such as long extraction time and large amount of solvent usage. To overcome these disadvantages, we aimed to establish a rapid residual analysis of benzo(a)pyrene content in agricultural products and soil samples. METHODS AND RESULTS: A Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method was used as the pretreatment procedure. For rapid residual analysis of benzo(a)pyrene, a modified QuEChERS method were used, and the best codition was demonstrated after various performing instrument analysis. The extraction efficiency of this method was also compared with Soxhlet extraction, the current benzo(a)pyrene extracting method. Although both methods showed high recovery rates, the rapid residual analysis method markedly reduced both the measurement time and solvent usage by approximately 97% and 96%, respectively. CONCLUSION: Based on these results, we suggest the rapid residual analysis method established through this study, faster and more efficient analysis of residual benzo(a)pyrene in major agricultural products such as rice, green and red chili peppers and also soil samples.

Mn-Modified PMN-PZT [Pb(Mg1/3Nb2/3)O3-Pb(Zr,Ti)O3] Single Crystals for High Power Piezoelectric Transducers

  • Oh, Hyun-Taek;Lee, Jong-Yeb;Lee, Ho-Yong
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.150-157
    • /
    • 2017
  • Three types of piezoelectric single crystals [PMN-PT (Generation I $[Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3]$), PMN-PZT (Generation II $[Pb(Mg_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3]$), PMN-PZT-Mn (Generation III)] were grown by the solid-state single crystal growth (SSCG) method, and their dielectric and piezoelectric properties were measured and compared. Compared to (001) PMN-PT and PMN-PZT single crystals, the (001) PMN-PZT-Mn single crystals exhibited a higher transition temperature between the rhombohedral and tetragonal phases ($T_{RT}=144^{\circ}C$), as well as a higher coercive electric field ($E_C=6.3kV/cm$) and internal bias field ($E_I=1.6kV/cm$). The (011) PMN-PZT-Mn single crystals showed the highest coercive electric field ($E_C=7.0kV/cm$), and the highest stability of $E_C$ and $E_I$ during 60 cycles of polarization measurement. These results demonstrate that both Mn doping (for higher electromechanical quality factor ($Q_m$)) and a (011) crystallographic orientation (for higher coercive electric field and stability) are necessary for high power transducer applications of these piezoelectric single crystals. Specifically, the (011) PMN-PZT-Mn single crystal (Gen. III) had the highest potential for application in the fields of SONAR transducers, high intensity focused ultrasound (HIFU), ultrasonic motors, and others.

진도개에서 초음파검사에 의한 분만일 예정표 확립 (Establishment of prediction table of parturition day by ultrasonography in Korean Jindo bitches)

  • 김세라;강현구;오기석;박인철;박상국;김성호;손창호
    • 대한수의학회지
    • /
    • 제40권2호
    • /
    • pp.373-381
    • /
    • 2000
  • Serial ultrasonographic examinations were performed on pregnant Korean Jindo bitches. Measurements of inner chorionic cavity diameter and fetal head diameter were made from pregnancy day 15 to parturition. These measurements were converted retrospectively based on the day of parturition (day 0). The data of inner chorionic cavity diameter obtained from day -42 to day -25 and fetal head diameter obtained from day -24 to day -1 were used to prediction of parturition day. Formulas for the prediction of parturition day using the method of least squares were derived. These formulas were then used to predict parturition dates based on single measurements of inner chorionic cavity diameter or fetal head diameter in 17 additional pregnant Korean Jindo bitches. Predicted date of parturition was then compared to actual whelping date. In the prediction of parturition based on inner chorionic cavity diameter, 7 of 10 bitches were coincided prediction date and actual whelping date, and the prediction was accurate to within 1 day in 3 of 10 bitches. The prediction of parturition based on fetal head diameter was accurate to within 1 day in 6 of 7 bitches and within 2 days in 1 of 7 bitches. In conclusion, the ultrasound measurement of inner chorionic cavity diameter and fetal head diameter are practical and accurate tool in the prediction of parturition.

  • PDF

Clinical application of chromosomal microarray for pathogenic genomic imbalance in fetuses with increased nuchal translucency but normal karyotype

  • Lee, Dongsook;Go, Sanghee;Na, Sohyun;Park, Surim;Ma, Jinyoung;Hwang, Doyeong
    • Journal of Genetic Medicine
    • /
    • 제17권1호
    • /
    • pp.21-26
    • /
    • 2020
  • Purpose: To evaluate the additive value of prenatal chromosomal microarray analysis (CMA) in assessing increased nuchal translucency (NT) (≥3.5 mm) with normal karyotype and the possibility of detecting clinically significant genomic imbalance, based on specific indications. Materials and Methods: Invasive samples from 494 pregnancies with NT ≥3.5 mm, obtained from the Research Center of Fertility & Genetics of Hamchoon Women's Clinic between January 2019 and February 2020, were included in this study and CMA was performed in addition to a standard karyotype. Results: In total, 494 cases were subjected to both karyotype and CMA analyses. Among these, 199 cases of aneuploidy were excluded. CMA was performed on the remaining 295 cases (59.7%), which showed normal (231/295, 78.3%) or non-significant copy number variation (CNV), such as benign CNV or variants of uncertain clinical significance likely benign (53/295, 18.0%). Clinically significant CNVs were detected in 11 cases (11/295, 3.7%). Conclusion: Prenatal CMA resulted in a 3% to 4% higher CNV diagnosis rate in fetuses exhibiting increased NT (≥3.5 mm) without other ultrasound detected anomalies and normal karyotype. Therefore, we suggest using high resolution, non- targeting CMA to provide valuable additional information for prenatal diagnosis. Further, we recommend that a genetics specialist should be consulted to interpret the information appropriately and provide counseling and follow-up services after prenatal CMA.

경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발 (A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery)

  • 윤상연;이기준;김재관;황재윤
    • 한국음향학회지
    • /
    • 제38권4호
    • /
    • pp.443-449
    • /
    • 2019
  • 심혈관계 질환 환자가 발생 하였을 때, 환자의 뇌와 내부 장기를 보호하고 생존율을 높이기 위해서는 사건발생 이후 신속하게 응급 의료 서비스를 제공하여 경과 시간을 줄이는 것이 가장 중요하다. 뿐만 아니라 심폐소생술의 실시를 위한 판단은 경동맥의 맥을 직접 짚는 '경동맥 촉진법'은 실시자의 주관적인 판단과 약해진 심혈관 기능에 따른 뇌혈류 차단을 할 수 있다. 본 연구는 개발된 다중 초음파 도플러 채널 쌍과 산소포화도 측정 모듈이 결합된 패치형 프로브를 이용하여 경동맥의 혈류 속도, 맥박, 산소포화도를 생체 내 실험을 통해 정성적으로 측정하였다. 따라서 본 시스템은 응급 상황에서 정량적이고 신속하게 환자의 심폐 기능을 모니터링 하여 심폐소생술 판단 여부를 객관적으로 제공하여 응급 상황 시 심혈관계 질환 환자의 생존률을 높일 수 있는 차세대 진단 기기로 활용 될 수 있다.

주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석 (Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering)

  • 강동열
    • 한국광학회지
    • /
    • 제30권2호
    • /
    • pp.48-58
    • /
    • 2019
  • 구면 초점 초음파 측정기에 의해 구형의 광 흡수체로부터 측정된 시간(즉, 펄스 형태 광원) 및 주파수 영역(즉, 처프 형태 광원) 광음향 신호의 신호 대 잡음비(signal-to-noise ratio)를 이론 및 시뮬레이션으로 분석하였다. 이전 문헌과 마찬가지로 시간 영역 광음향 측정에 의한 신호 대 잡음비 값이 주파수 영역 광음향 측정의 경우보다 더 높았는데 이 근본적인 이유를 최대허용노광량(maximum permissible exposure)에 따른 광원의 세기와 주파수 필터링을 통한 두 측정 모드의 광음향 스펙트럼들에 대한 분석을 통해 이해하였다. 또한, 분석의 결과로서 주파수 영역 광음향의 처프 형태 광원에 대한 정합 필터링에 더해 DC 스펙트럼 부분을 제거하니 신호 대 잡음비가 5 dB 정도 상승하는 것을 발견하였다. 특히, 주파수 필터 함수의 주파수 상한 값의 변화에 따라 신호대 잡음비 값이 급격하게 변동하였는데 신호 대 잡음비가 최대가 되는 주파수 상한 값이 두 광음향 측정 모드에서 서로 다르게 나타남을 관찰하였다.