• Title/Summary/Keyword: Ultrasound measurement

Search Result 328, Processing Time 0.034 seconds

Acoustic Estimation of Phase Velocity of Closed-Cell Kelvin Structure based on Spectral Phase Analysis

  • Kim, Nohyu
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.339-345
    • /
    • 2022
  • In this paper, the effect of porosity on the acoustic phase velocity of the 3D printed Kelvin closed-cell structure was investigated using the spectral phase analysis. Since Kelvin cells bring about the large amount of scattering, acoustic pulses in ultrasonic measurements undergoes a distortion of waveforms due to the dispersion effect. In order to take account on the dispersion, mathematical expressions for calculating the phase velocity of longitudinal waves propagating normal to the plane of the Kelvin structure are suggested by introducing a complex wave number based on Fourier transform. 3D Kelvin structure composed of identical unit-cells, a polyhedron of 14 faces with 6 quadrilateral and 8 hexagonal faces, was developed and fabricated by 3D CAD and 3D printer to represent the micro-structure of porous materials such as aluminum foam and cancellous bone. Total nine samples of 3D Kelvin structure with different porosity were made by changing the thickness of polyhedron. Ultrasonic pulse of 1MHz center frequency was applied to the Kelvin structures for the measurement of the phase velocity of ultrasound using the TOF(time-of-flight) and the phase spectral method. From the experimental results, it was found that the acoustic phase velocity decreased linearly with the porosity.

A Study of Improve on a Backscatter Data of Multibeam Echo-sounder Using Digital Image Processing (디지털 영상처리기법를 이용한 멀티빔 음향측심기의 음압자료 향상 연구)

  • Hye-Won Choi;Doo-Pyo Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.133-141
    • /
    • 2023
  • Accurate measurement of seafloor topography plays a crucial role in developing marine industries such as maritime safety, resource exploration, environmental protection, and coastal management. The seafloor topography is constructed using side scan sonar (SSS) and single beam echosounder (SBES) or multibeam echosounder (MBES), which transmit and receive ultrasound waves through a device attached to a marine survey vessel. However, the use of a sonar system is affected by noise pollution areas, and the single beam has a limited scope of application. At the same time, the multibeam is mainly applicable for depth observation. For these reasons, it is difficult to determine the boundaries and areas of seafloor topography. Therefore, this study proposes a method to improve the backscatter data of multibeam echosounder, which has a relationship with the seafloor quality, by using digital image processing to classify the shape of the underwater surface.

Morphological Changes in Quadriceps Muscles through 3-Week Combined Exercise using a Wearable Robot (EX1) in Young Adult

  • Jang-hoon Shin;Naeun Byeon;Heeju Yu;DaeEun Kim;Byungmun Kang;Dongwoo Kim;Hwang-jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.1
    • /
    • pp.33-42
    • /
    • 2023
  • Objective: This study aims to analyze the effect of regular exercise through the combined walking-oriented aerobic and resistance exercises using EX1 in young adults. Design: Experimental one group pre and post test Methods: Participants comprised17 healthy young adults. All subjects performed a combined exercise program for 10 times using EX1. We measured quadriceps muscle thickness using ultrasound. Additionally, the hand grip strength test, and sit and reach test were performed before and after the exercise. Through paired t-test, we investigated whether there was a statistically significant difference in the measurement results after exercise program. Results: The rectus femoris muscle contraction ratio showed significant difference after exercise(P< 0.01). In the sit and reach test, flexibility showed significant difference after exercise(P < 0.01). The hand grip strength test also showed significant difference after exercise(P < 0.05). Conclusions: Healthy young adults can effectively perform various exercises commonly performed in daily life using EX1.

Measurement of the Common Carotid Artery by Ultrasound as a Predictor of Atherosclerosis in Obese Adolescents (비만 청소년에서 동맥경화증을 조기에 예측하기 위한 경부 초음파를 이용한 경동맥 측정)

  • Kim, Ye Jin;Shim, Yoon Hee;Yoo, Joung Hyun;Lee, Keun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.745-752
    • /
    • 2005
  • Purpose : Adolescent obesity is known to be associated with complications such as hypertension, coronary artery disease and insulin resistance. We measured the common carotid artery by ultrasound as a predictor of atherosclerosis, and investigated the relationship between carotid artery parameters and serum cytokines in obese adolescents. Methods : Twenty-nine obese adolescents(16-17 years old, obesity index>130 percent) and twentyseven normal controls were included. Obesity index and body mass index were calculated from their height and weight. Skin fold thickness was measured at the triceps, and fat mass and fat distribution by bioelectrical impedence analysis. Blood pressure was measured at resting state and serum lipid, insulin, and homocysteine levels after a 12-hour fasting period. Intimal wall thickness, systolic and diastolic diameters of the common carotid artery were measured by ultrasound, and compliance and distensibility calculated by equation. Results : Systolic and diastolic diameters of the carotid artery significantly correlated with arm circumference, body mass index, fat distribution and fat mass. The higher systolic blood pressure was, the larger systolic and diastolic diameter. The higher diastolic blood pressure was, the larger carotid intimal thickness. Insulin levels had positive correlations with systolic, diastolic diameters and serum homocysteine level with intimal thickness. Conclusion : The carotid artery diameter significantly increased with the degree of obesity and blood pressure. The carotid intimal wall thickness significantly correlated with diastolic blood pressure. Measurement of carotid artery thickness, insulin and homocysteine levels might be useful to predict the development of coronary artery disease.

Clinical Study of Long Term Effect of Transvaginal Ultrasound Guided Radiofrequency Myolysis for Treatment of Uterine Leiomyoma (자궁근종 치료를 위한 질경유 초음파 유도하 고주파 자궁근종용해술의 장기간 효과에 대한 임상적 연구)

  • Lee, Woo-Seok;Lee, Il-Han;Kim, Dong-Ho;Lee, Sang-Hun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Objective: This study was performed to investigate the efficacy and safety of radiofrequency (RF) myolysis under transvaginal ultrasound guidance. Methods: Transvaginal RF myolysis had been performed in one hundred nine women with uterine leiomyoma at Chung-Ang University hospital between Dec. 2004 and Mar. 2007. All patients, mean aged $42.8{\pm}5.8$ years, desired their uterine conservation. Patients underwent physical examination, transvaginal pelvic ultrasound for measurement of the lesions preoperatively. Follow up was done at 1 week, 1 month, 3 months, 6 months after RF myolysis by same physician and measurement of size and volume of myoma and improvement of myoma specific symptoms such as menorrhagia and dysmenorrhea were checked at each visit. Results: The mean maximal diameter of myomas treated by RF myolysis was $6.1{\pm}0.5\;cm$ and average time of the procedure was $16.3{\pm}8.5$ minutes. A significant decrease of myoma size and volume was observed at 1 month after myolysis. Mean reduction in maximal diameter was $29.9{\pm}4.8%$ at 1 week (p<0.001), $41.5{\pm}1.5%$ at 1 month (p=0.05), $46.2{\pm}3.9%$ at 3 months (p=0.003), $54.6{\pm}6.1%$ at 6 months (p<0.001) after RF myolysis respectively. Mean reduction in volume was $44.4{\pm}8.3%$ (p=0.001), $68.1{\pm}4.2%$ (p=0.035), 73.9$73.9{\pm}4.8%$ (p=0.042), $84.5{\pm}5.1%$ (p<0.001) at the same follow up period respectively. Significant improvement of symptom was observed at 3 months after RF myolysis. Transient low abdominal pain and prolonged vaginal bleeding were detected in 3 patients each but spontaneously resolved and no serious complication has been noticed or found. Conclusion: This study shows transvaginal RF myolysis could be a safe and effective method to treat uterine leiomyoma, allowing uterine conservation with significant volume reduction and rapid return to normal activity.

Diagnostic value of Thyroglobulin Measurement with Fine-needle Aspiration Biopsy for Lymph Node Metastases in Patients with a History of Differentiated Thyroid Cancer

  • Zhang, Hai-Shan;Wang, Ren-Jie;Fu, Qing-Feng;Gao, Shi;Sun, Bu-Tong;Sun, Hui;Ma, Qing-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10905-10909
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the diagnostic value of FNA-Tg for detecting lymph node metastases in patients with a history of differentiated thyroid cancer (DTC). Materials and Methods: A total of 58 patients with DTC diagnosis and evidence of single or multiple suspicious cervical lymph nodes were assessed. All underwent total or near-total thyroidectomy with (35 cases) or without (23 cases) radioiodine (RAI) ablation, followed by thyroid stimulating hormone (TSH) suppression therapy. A total of 68 lymph nodes were examined by ultrasound-guided fine needle aspiration (US-FNA) for both cytological examination and FNA-Tg measurement. Serum Tg and anti-thyroglobulin antibody (TgAb) levels were also measured. Diagnostic performance including sensitivity, specificity, accuracy, positive (PPV) and negative predictive value (NPV) of FNAC and FNA-Tg were calculated and compared. The Spearman's rank correlation coefficient was used to estimate the relationship between FNA-Tg and serum TgAb. Results: The FNA-Tg levels were significantly higher with DTC metastatic lymph nodes (median 927.7 ng/mL, interquartile range 602.9 ng/mL) than non-metastatic lymph nodes (median 0.1 ng/mL, interquartile range 0.4 ng/mL) (p<0.01). Considering 1.0 ng/mL as a threshold value for FNA-Tg, the sensitivity, specificity, accuracy, PPV and NPV of FNA-Tg were 95.7%, 95.5%, 95.6%, 97.8% and 91.3%, respectively. The sensitivity and accuracy of the combination of FNAC and FNA-Tg were significantly higher than that of FNAC alone (p<0.05). The diagnostic performance of FNA-Tg was not significantly different between cases with or without RAI ablation, and the serum TgAb levels did not interfere with FNA-Tg measurements. Conclusions: Measurement of FNA-Tg is useful. The combination of FNAC and FNA-Tg is more sensitive and accurate for detecting lymph node metastases in patients with a history of DTC than FNAC alone. Serum TgAbs appear to be irrelevant for measurement of FNA-Tg.

Measurements of Ultrasound Attenuation Coefficient at Various Suspended Sediment Concentrations (부유물 농도 변화에 따른 초음파 신호의 감쇠계수 측정)

  • Lee, Changil;Choi, Jee Woong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Coastal water including estuaries has distinctive environmental characteristics where sediments are transported and deposited by flowing river water, providing an environment in which fluid mud layers can be formed. Acoustic method is mostly used to detect or monitor the fluid mud layer. However, since sound propagating in this layer suffers severe attenuation, it is important to estimate the accurate attenuation coefficient for various concentrations of fluid mud layer for the successful use of the acoustic method. In this paper, measurement results of attenuation coefficient for 3.5, 5, and 7.5 MHz ultrasounds were presented. The measurements were made in a small-size water tank in which suspended sediment samples with various sediment concentrations were formed using kaolinite powder. The results were compared to the model predictions obtained by attenuation coefficient model in which the mean grain size (called as Mass-median-diameter, D50) was used as input parameter. There were reasonable agreements between measured attenuation coefficients and model outputs predicted using the particle range of D50 ${\pm}20%$. The comparison results imply that although the suspended sediments consist of various-sized particles, sound attenuation might be greatly influenced by amount of particle with a size which has a larger attenuation than that of any particle in the suspended sediments for the frequency used.

The Relationship between Perceived Stress Scale and Carotid Intima-Media Thickness Using Ultrasonography in University Students (대학생들의 스트레스 지각 정도와 경동맥 내막-중막 두께의 관계 연구)

  • Kim, Dae-Sik;Sung, Hyun-Ho;Lee, Jong-Woo;Cho, Eun-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.308-315
    • /
    • 2017
  • Carotid artery intima-media thickness (CIMT) test is a standardized ultrasound procedure that screens for and monitors atherosclerosis in a safe and non-invasive manner, even in individuals with no symptoms of heart disease. The purpose of this study was to research the relationship between CIMT, as measured by ultrasonography, and the degree of individual perceived stress. There was a total of 168 (male: 46, female: 122) university students in Suwon-si, Gyeonggi-do, Korea, without other diseases. Written informed consent was obtained from all participants. CIMT was measured in the right and left common carotid arteries 1 cm below the bifurcation, and internal carotid artery, using non-invasive high-resolution Medison Accuvix V20 prestige ultrasound equipment and perceived stress, was measured with the 10-item PSS (Perceived Stress Scale) questionnaire. This study indicates that PSS may be appropriate to estimate perceived stress levels and weight. Failure to control stress anxiety could lead to weight and CIMT soaring to dangerous levels, resulting in a myocardial infarction or cerebrovascular accident. There was a statistically significant difference between left CIMT (p<0.05) and weight (p<0.05) according to each stress classification. The results of this study suggest that the weight measurement is influenced in part by one's generalized stress levels. Future continuous studies should be conducted to test the influences of perceived stress and generalized anxiety on CIMT when these are many continuous variables.

A Study on Estimation of Carotid Intima-Media Thickness(IMT) using Pulse Wave Velocity(PWV) (맥파전달속도를 이용한 내중막 두께 추정에 관한 연구)

  • Song, Sang-Ha;Jang, Seung-Jin;Kim, Wuon-Shik;Lee, Hyun-Sook;Yoon, Young-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.401-411
    • /
    • 2009
  • In this paper, we correct pulse wave velocity(PWV) with heart-rate and derive regression equations to estimate intima-media thickness(IMT). Widely used methods for diagnosis of arteriosclerosis are IMT and PWV. Arterial wall stiffness determines the degree of energy absorbed by the elastic aorta and its recoil in diastole but there is not correlation between sclerosis and IMT in an existing study. In this study, we will correct PWV with heart-rate and get regression equation to estimate IMT using heart-rate correction index(HCI). We executed experiments for this study. Made up question of physical condition and measured electrocardiogram(ECG), photoplethysmogram (PPG) of finger-tip and toe-tip and ultrasound image of carotid artery. Calculated PWV and IMT using ECG, PPG and ultrasound image. We found that every p-value between PWV and IMT is not significant(<0.05). But p-value between IMT and HCI which is a corrected PWV using heart-rate is significant(>0.01). We use HCI and various measured parameter for estimating regression equation and apply backward estimation to select parameters for regression analysis. Result of backward estimation, found that only HCI is possible to derive proper regression equation of IMT. Relationship between PWV and IMT is the second order. Result of regression equation of E-H PWV is $R^2$=0.735, adj $R^2$=0.711. This is the best correlation value. We calculate error of its analysis for verification of earlobe PWV regression equation. Its result is RMSEP=0.0328, MAPE(%) = 4.7622. Like this regression analysis, we know that HCI is useful parameter and relationship between PWV, HCI and IMT. In addition, we are able to suggest possibility which is that we can get different parameter of prediction throughout just one measurement.

Platelet Rich Plasma Injection: Evidence Based Analysis (혈소판 풍부 혈장 주사 요법: 근거 중심의 분석)

  • Oh, Joo Han;Chung, Seok Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.111-122
    • /
    • 2011
  • Platelet rich plasma (PRP) has been widely used nowadays for several common orthopaedic-related sports medicine conditions with the theoretical basis that PRP supplies numerous autologous growth factors from concentrated platelets needed to promote the healing process of injured tissue. Even though there are many basic sciences, animal studies and some clinical studies regarding PRP injections for musculoskeletal injuries which suggested good results, it is difficult to compare these various studies due to marked methodological differences such as PRP preparation method, the timing, volume and number of injection, and the outcome measurement tool. In addition, many studies have no control groups or a limited sample size, and there are few prospective randomized controlled trials assessing the efficacy of PRP injections. Therefore, well designed high-quality randomized studies are required to confirm the preliminary results until now and provide scientific evidence to support its use, and the paucity of scientific clinical evidence suggest that the administration of PRP on humans for musculoskeletal injuries should be performed with caution.

  • PDF