• Title/Summary/Keyword: Ultrasound measurement

Search Result 328, Processing Time 0.027 seconds

Osteoporosis Measured by Quantitative Ultrasound and Its Risk factors in Middle-aged Women, Gyeonggi-do, Korea (중년여성의 정량적 초음파(Quantitative Ultrasound)로 측정한 골다공증 정도와 위험인자)

  • Jeong, Geum-Hee;Yang, Soon-Ok;Baik, Sung-Hee
    • Journal of muscle and joint health
    • /
    • v.12 no.1
    • /
    • pp.39-47
    • /
    • 2005
  • Purpose: To identify Osteoporosis and the related risk factors in middle-aged women, the descriptive survey was done. Method: The subjects were measured in 465 residents who were 40-60 aged healthy women. They underwent ultrasound measurement and health examination in G city's Health Center in Gyeonggi-do, Korea from July 2000 to March 2001. The self-reported questionnaire consisted of total 17 items about risk factors related to osteoporosis. The evaluation of bone density was based on ultrasound measurements of right heel. All data were analyzed by SAS-PC Program. Result: Mean age of the subjects was 46.7. Mean T score related to bone density was -1.30, ranged from -3.52 to 3.06. In diagnosis classification according to T score, 74.8% of subjects was normal, 12.9% was osteopenia, 12.3% was osteoporosis. Among risk factors, there were significant differences by age (t=15.35. p=0.000), parity (F=12.81, p=0.000), menopause status (t=22.05, p=0.000), period after menopause (F=5.20, p=0.006). The higher frequency of delivery, postmenopausal and longer period after postmenopause of subjects had the lower the bone density. Conclusion: It would be necessary to develop and apply the community-based health promotion program for middle-aged women to prevent osteoporosis.

  • PDF

The Effects of Ultrasound Imaging Visual Feedback During Toe-Spread-Out Exercise in Subjects With Hallux Valgus (엄지발가락가쪽휨증의 발가락벌리기 운동 시 초음파 영상을 이용한 시각적 피드백의 효과)

  • Kang, Sun-young;Choung, Sung-dae;Shim, Jae-hoon
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.21-28
    • /
    • 2016
  • Background: The toe-spread-out (TSO) exercise has been introduced as a strengthening exercise for the abductor hallucis muscle in subjects with hallux valgus. Visual biofeedback using ultrasound imaging during exercise, may increase the ability to selectively contract the abductor hallucis muscle, compared with exercise alone. Objects: The aim of this study was to investigate the effects of ultrasound imaging visual feedback during the TSO exercise with respect to its influence on the angle of the first metatarsophalangeal joint (1st MPJ) and the cross-sectional area (CSA) of the abductor hallucis muscle in subjects with hallux valgus. Methods: Twenty-five healthy young subjects with a mean average age of 22.5 years, and a standard deviation of 2.3 years, were recruited for this study. Hallux valgus was defined as an angles greater than $15^{\circ}$ angle of 1st MPJ. Goniometric measurement was used to determine the angle of 1st MPJ. In addition, an ultrasound system was used to collect the CSA of the abductor hallucis muscle in each foot. The angle of the 1st MPJ and CSA of the abductor hallucis were measured in three positions; the resting position, during TSO exercise, and during TSO exercise in conjunction with real-time ultrasound imaging feedback. All data analyzed using a repeated analysis of variance with Bonferroni correction in order to compare the dependent variables in all three positions. Statistical level of significance was set up as p<.05. Results: The angle of the 1st MPJ was noted to be significantly reduced and the CSA of the abductor hallucis to be significantly greater during TSO exercise used in conjunction with ultrasound imaging visual feedback, compared to when the values were recorded during TSO exercise alone (p<.05). Conclusion: Based on these findings, it can be concluded that the application of ultrasound imaging visual feedback during TSO exercise is more effective in contracting selectively the abductor hallucis than the use of exercise alone.

The Principle and a Prototype System for Burning Rate Measurement of Solid Propellants Using Ultrasound (초음파를 이용한 고체추진제 연소속도 측정원리 및 시범시스템 개발)

  • Song, Sung-Jin;Jeon, Jin-Hong;Kim, Hak-Joon;Oh, Hyun-Taek;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.61-68
    • /
    • 2006
  • To measure burning rate of solid propellants using ultrasound, a special closed bomb and an ultrasonic and pressure measurement system are fabricated. During pressurization tests and homing tests on propellants, ultrasonic and pressure signal are acquired in real time fashion by this system. Based on acquired signals, analysis programs using two different algorithm which can measure burning rates corresponding to pressures are compared. One algorithm is to correct sound velocity variation of propellants and solid couplant, another one is only to correct sound velocity variation of propellants. And accuracies of homing rates measured through these algorithms are calculated through comparison with the burning rates measured using strand burner method.

Reliability and validity of rehabilitative ultrasound images obtained using a hands-free fixed probe in measuring the muscle structures of the tibialis anterior and the gastrocnemius

  • Choi, Mun-Sang;Shin, Jang-Hoon;Park, Hye-Kang;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.194-201
    • /
    • 2019
  • Objective: This study aimed to investigate the reliability and validity of muscle thickness (MT) and pennation angle (PA) measurements of the ankle muscle, including the tibialis anterior (TA) and the medial gastrocnemius (MGCM), using a hands-free fixed probe and to compare it with the conventional linear probe. Design: Observational inter-rater reliability study. Methods: Thirty-three healthy subjects (20 male, 13 female) were included. In all subjects, ultrasound images were acquired from the TA and MGCM using a hands-free fixed probe and a conventional linear probe in random sequence by two examiners at two time-points within a 7-day interval. MT and PA were calculated on the taken images. Intra-class correlation coefficients (ICC), 95% confidence intervals, standard error of measurement and the Pearson's correlation coefficient were used to estimate reliability and validity. And also, Bland-Altman plots were generated for a visual representation of MT and PA at the TA and MGCM. Results: The ICC for all intra-rater reliability was 0.943 to 0.995 and that for all inter-rater reliability was 0.928 to 0.993, indicating excellent reliability. A significantly high correlation was observed between MT and PA at the TA and MGCM with use of the hands-free fixed probe and the conventional linear probe (r>0.938; p<0.001). Conclusions: The hands-free fixed probe provided excellent images for measurement of the MT and PA of the TA and MGCM and is a useful device for making clinical measurements of muscle structure without grasping of the probe.

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

Ultrasonographic Measurement of the Ligamentum Flavum Depth : Is It a Reliable Method to Distinguish True and False Loss of Resistance?

  • Pak, Michael Hae-Jin;Lee, Won-Hyung;Ko, Young-Kwon;So, Sang-Young;Kim, Hyun-Joong
    • The Korean Journal of Pain
    • /
    • v.25 no.2
    • /
    • pp.99-104
    • /
    • 2012
  • Background: Previous studies have shown that if performed without radiographic guidance, the loss of resistance (LOR) technique can result in inaccurate needle placement in up to 30% of lumbar epidural blocks. To date, no study has shown the efficacy of measuring the depth of the posterior complex (ligamentum flavum, epidural space, and posterior dura) ultrasonographically to distinguish true and false LOR. Methods: 40 cervical epidural blocks were performed using the LOR technique and confirmed by epidurograms. Transverse ultrasound images of the C6/7 area were taken before each cervical epidural block, and the distances from the skin to the posterior complex, transverse process, and supraspinous ligament were measured on each ultrasound view. The number of LOR attempts was counted, and the depth of each LOR was measured with a standard ruler. Correlation of false and true positive LOR depth with ultrasonographically measured depth was also statistically analyzed. Results: 76.5% of all cases (26 out of 34) showed false positive LOR. Concordance correlation coefficients between the measured distances on ultrasound (skin to ligamentum flavum) and actual needle depth were 0.8285 on true LOR. Depth of the true positive LOR correlated with height and weight, with a mean of $5.64{\pm}1.06cm$, while the mean depth of the false positive LOR was $4.08{\pm}1.00cm$. Conclusions: Ultrasonographic measurement of the ligamentum flavum depth (or posterior complex) preceding cervical epidural block is beneficial in excluding false LOR and increasing success rates of cervical epidural blocks.

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.

In-line measurement of residence time distribution in twin-screw extruder using non-destructive ultrasound

  • Lee, Sang-Myung;Park, Jong-Cheol;Lee, Sang-Mook;Ahn, Young-Joon;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.2
    • /
    • pp.87-95
    • /
    • 2005
  • In this study, we performed RTD measurement at the die exit of co-rotating twin-screw extruder using a non-destructive ultrasonic device. The ultrasonic device was attached at slit die and was composed of a steel buffer rod and 10 MHz longitudinal piezoelectric ultrasonic transducer. This in-line ultrasonic monitoring method is based on the ultrasonic response of $CaCO_3$ filled in polymer. The RTD is evaluated by variation of ultrasonic attenuation with time caused by change of the tracer concentration during extrusion. The ultrasonic tracer, pellet type of compounded $CaCO_3$ in polymer was used in this study. The effects of tracer concentration on RTD and flow patterns were studied. Evaluation for the residence functions at different screw speeds, feeding rates and screw configurations were also carried out.

Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis (3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가)

  • Noh, Si-Cheol;Kim, Ju-Young;Park, Jae-Hyun;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.