• Title/Summary/Keyword: Ultrasound guided biopsy

Search Result 76, Processing Time 0.019 seconds

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Clinical Application of Ultrasound-Guided Thyroid Fine Needle Aspiration Biopsy and Thinprep Cytology Test in Diagnosis of Thyroid Disease

  • Wei, Ying;Lu, Yao;Li, Chenxi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4689-4692
    • /
    • 2016
  • Purpose: To study the clinical application value of ultrasound guided thyroid fine needle aspiration biopsy and thinprep cytology testing in diagnosis of thyroid disease. Methods: A total of 78 patients with thyroid nodules were enrolled, 34 males and 44 females, aged 33-64 years old with mean age of 47.6 years. All underwent thyroid module fine needle puncture after surgery to assess cell pathology and histopathological features. Results: Sufficient specimens were obtained from all of 78 patients, the cytological results of 73 cases (93.6 %) being consistent with pathological results. While 20 cases (25.6 %) were malignant tumors, 44 (56.4 %) were benign and 9 (11.5 %) were non-tumor lesions. The sensitivity of benign and malignant thyroid nodule by thyroid fine needle puncture was 90.9 %, specificity was 98.1 % and the positive predictive value was 96.3 %. Conclusions: It is demonstrated that ultrasound-guided thyroid fine needle aspiration biopsy and thinprep cytology testing have diagnostic value in clinical application for thyroid disease,showing good diagnostic coincidence rates with histopathological examination. They can thus be regarded as safe and effective for preoperative diagnosis and providing an appropriate basis for selection of surgery.

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Diagnostic Approach of Hepatic Mass using Ultrasound Guided Fine Needle Aspiration in a Dog (개에서 초음파를 이용한 간 종괴의 세침흡인술 증례)

  • 최호정;이기창;최민철;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.181-183
    • /
    • 2004
  • Hepatic mass was aspirated under the guidance with ultrasound in 9-year old female maltese with signs of anorexia, hematochezia, vomiting, depression, and abdominal distension. Radiographic and abdominal ultrasonographic examinations were performed, which revealed enlarged tubular shaped uterine mass and solitary, small round hyperechoic hepatic mass dorsal to gall bladder as an incidental finding. Ultrasound-guided fine needle aspiration was completed, but histologic confirmation should be made for definitive diagnosis by tissue core or wedge biopsy.

Transvaginal Ultrasound-Guided Biopsy (경질 초음파 유도생검)

  • Su Hyeok Lim;Jung Jae Park;Chan Kyo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1233-1243
    • /
    • 2023
  • Percutaneous ultrasound-guided biopsy is useful for the pathologic confirmation of variable body lesions to establish diagnostic and therapeutic approaches. However, deep pelvic lesions are a challenge for pathologic diagnoses because of the presence of the bowel, bladder, major vessels, and pelvic bones which make a percutaneous approach difficult and dangerous. In female, the vagina is elastic and near the pelvic internal organs. Therefore, transvaginal ultrasound may serve as an effective and safe guide for the pathologic diagnosis of pelvis lesions. This review aimed to introduce the indications for, and the method of transvaginal ultrasoundguided biopsy, and to describe the reported diagnostic accuracy and safety.

Ultrasound-Guided Intervention for Breast Lesions (유방 병변에 대한 초음파 유도하 중재 시술)

  • Eun Young Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.332-344
    • /
    • 2023
  • The role of ultrasound-guided interventions in the diagnosis and treatment of breast lesions is gaining importance and prevalence, particularly as the instances of non-palpable breast lesion detection, breast-conserving surgery, and neoadjuvant chemotherapy are increasing. This review attempts to summarize the types and techniques of breast ultrasound-guided interventional procedures, such as biopsy, tissue marker insertion, and preoperative localization, and their indications. Furthermore, we highlight the pro and cons of the most commonly used procedures with the intention of promoting their use in clinical practice.

Availability of Positron Emission Tomography-Computed Tomography for the Diagnosis of the Soft Tissue Tumor through Ultrasound-Guided Biopsy (초음파 유도하 침 생검을 이용한 연부조직 종양의 진단에 있어 양전자방출 컴퓨터 단층촬영술의 유용성)

  • Jun, Se Bin;Kim, Jeung Il;Lee, In Sook;Song, You Seon;Choi, Kyung Un
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.398-403
    • /
    • 2021
  • Purpose: A biopsy is needed to diagnose soft tissue tumors. However, it is extremely difficult to pinpoint the site of a tumor due to the heterogeneity of sarcomas. Thus, even when an open biopsy is conducted, it is difficult to diagnose a soft tissue tumor. In such cases, an ultrasound (US)-guided biopsy is used to improve the diagnostic accuracy. This study evaluated the accuracy of US-guided biopsy for a diagnosis of soft tissue tumors found initially in a magnetic resonance (MR) perfusion and assessed the availability of positron emission tomography-computed tomography (PET-CT) for a diagnosis of soft tissue tumors. Materials and Methods: From January 2014 to December 2018, the US-guided biopsy was performed on 152 patients with a suspected soft tissue tumor found in an MR perfusion and 86 cases were definitively diagnosed with a soft tissue tumor. The accuracy of the US-guided biopsy was assessed retrospectively. Among the 86 cases, only MR perfusion was used before the biopsy in 50 cases, while both MR perfusion and PET-CT was conducted on 36 cases. The accuracy was analyzed to determine if the PET-CT could improve the precision of a biopsy. Results: From 86 cases, 34 out of 50 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 32 out of 36 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis and the US-guided biopsy. These results show significant differences in the accuracy of US-guided biopsy. In the case of soft tissue sarcomas, 6 out of 12 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 17 out of 18 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis. Moreover US-guided biopsy also showed significant differences in the accuracy of US-guided biopsy. Conclusion: In diagnosing soft tissue tumors, a US-guided biopsy is a well-known tool for its high accuracy. However, the heterogeneity of sarcoma makes it difficult to locate the exact site for a biopsy using only MR perfusion. Thus, the use of PET-CT will meaningfully improve the accuracy of a diagnosis by precisely targeting the site for the US-guided biopsy.

Hemorrhagic Complications Following Ultrasound-Guided Breast Biopsy: A Prospective Patient-Centered Study

  • Heera Yoen;Hyun-Ah Chung;So-Min Lee;Eun-sung Kim;Woo Kyung Moon;Su Min Ha
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.157-165
    • /
    • 2024
  • Objective: We aimed to evaluate the clinical and imaging factors associated with hemorrhagic complications and patient discomfort following ultrasound (US)-guided breast biopsy. Materials and Methods: We prospectively enrolled 94 patients who were referred to our hospital between June 2022 and December 2022 for US-guided breast biopsy. After obtaining informed consent, two breast radiologists independently performed US-guided breast biopsy and evaluated the imaging findings. A hemorrhagic complication was defined as the presence of bleeding or hematoma on US. The patients rated symptoms of pain, febrile sensation, swelling at the biopsy site, and dyspnea immediately, 20 minutes, and 2 weeks after the procedure on a visual analog scale, with 0 for none and 10 for the most severe symptoms. Additional details recorded included those of nausea, vomiting, bleeding, bruising, and overall satisfaction score. We compared the clinical symptoms, imaging characteristics, and procedural features between patients with and those without hemorrhagic complications. Results: Of 94 patients, 7 (7%) developed hemorrhagic complications, while 87 (93%) did not. The complication resolved with 20 minutes of manual compression, and no further intervention was required. Vascularity on Doppler examination (P = 0.008), needle type (P = 0.043), and lesion location (P < 0.001) were significantly different between the groups. Patients with hemorrhagic complications reported more frequent nausea or vomiting than those without hemorrhagic complications (29% [2/7] vs. 2% [2/87], respectively; P = 0.027). The overall satisfaction scores did not differ between the two groups (P = 0.396). After 2 weeks, all symptoms subsided, except bruising (50% 2/4 in the complication group and 25% [16/65] in the no-complication group). Conclusion: US-guided breast biopsy is a safe procedure with a low complication rate. Radiologists should be aware of hemorrhagic complications, patient discomfort, and overall satisfaction related to this procedure.

A Clinical Consideration of Necrotizing Lymphadenitis (괴사성 림프절염에 대한 임상적 고찰)

  • 유명종;조우령;김학선;이재동;김명구
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.2
    • /
    • pp.164-171
    • /
    • 2000
  • Background and Objectives: Necrotizing lymphadenitis or Kikuchi's disease is characterized by cervical lymphadenopathy of unknown etiology with unique histologic findings in young female patients. The importance of this disease lies in the fact that it can be easily misdiagnosed as malignant lymphoma, hence, clinicians need to aware of this disease entity. The purpose of this study is to report the clinicopathologic findings, radiographic findings, and many laboratory tests in order to contribute to the diagnosis and treatment of necrotizing lymphadenitis. Materials and Methods: We evaluated 31 patients, who were diagnosed as necrotizing lymphadenitis by excisional biopsy or fine needle aspiration cytology or ultrasound guided 18G cutting needle biopsy, retrospectively. Result : The median age was 24.8 years (range 12 to 43 years) and the male to female ratio was 1 : 2.4(9:22), with 14 females (45.1%) under 30 years. The common chief complaints were neck mass, easy fatigue and fever. Lymph node enlargement was limited to the cervical area in most cases (28cases : 90.3%). The involved lymph nodes were usually multiple (20cases : 64.5%), unilateral (26cases 83.9%) and small sized. Leukopenia (19cases : 61.3%) and elevation of ESR (18cases : 58.1%) appeared most frequently in the abnormal laboratory data. These symptoms will be gone spontaneoulsy without any specific treatment in several weeks or months. Conclusion : We should consider open biopsy or fine needle aspiration cytology or ultrasound guided cutting needle biopsy with lymph node in patients who have cervical lymphadenopathy with easy fatigue and fever, especially young women to exclude other conditions such as malignant lymphoma and tuberculosis, etc.

  • PDF

Observation of Changes in Indoor Formaldehyde(HCHO) Concentration during Ultrasound Guided Biopsy (초음파 조직생검 시 실내의 포름알데히드(HCHO) 농도 변화 관찰)

  • Lee, Hoon-Jeong;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1057-1064
    • /
    • 2021
  • This study was conducted by simulating the same environmental conditions as the actual biopsy to observe the change in formaldehyde(HCHO) concentration in the indoor air during ultrasound guided biopsy. Changes in HCHO concentration in the room were measured by successively performing five steps: sealing the ultrasound room, ventilation, opening formalin containers, sealing formalin containers, and re-ventilating. Trends of measured HCHO concentration changes were visualized using graphs. As a result of analyzing the consistency of the concentration change values measured three times using the intra-class correlation coefficient, it was found to be 0.989, which was statistically significant(p<0.05). Based on the results of this study, we hope that medical workers working in the HCHO exposure environment of the field of radiology part will improve their awareness of the necessity of exposure management at work, and actively discuss the establishment of an environment for exposure control and preparation of countermeasures.