• Title/Summary/Keyword: Ultrasound Test

Search Result 399, Processing Time 0.025 seconds

A Study on the Illumination Environment of Ultrasound Examination Room (초음파 검사실의 조도 환경에 관한 연구)

  • Im, In-Chul;Lee, Hyo-Yeong;An, Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • The purpose of study is provide the basic data for set up proper illuminance of examination room that put purpose of an empirical study basic data about examination environment setting of the ultrasonic examination on design the examination environment of a new ultrasonic examination. As a method, to investigate the ultrasonic environment related to illumination to take a survey on the ultrasonic examination about test object to 48 parts of six units of general hospital in Busan. As a result, All Door + Curtain showed high scores in analyzing the gender, age, examination part in the case of ultrasonic examination room shielding and LED and light source control is required in the case of kind of light source. In the ultrasonic examination environment survey, the illuminance brightness is average 10 Lux which is included illuminance brightness range recommended the WHO and CEC and illuminance brightness of ultrasonic examination waiting room(ultrasonic examination waiting room, corridor) indicate average 300~800 Lux and it satisfied hospital illumination environment more than 300 Lux recommended by KSA 3011. In conclusion, Basic data suggested that improved future ultrasonic examination environment or designed new examination room on the basis of analysis result of general background and ultrasonic examination related to environment factor.

Signal-Characteristic Analysis with Respect to Backing Material of PVDF-Based High-Frequency Ultrasound for Photoacoustic Microscopy (광음향 현미경을 위한 PVDF 기반 고주파수 초음파 변환기의 흡음층 소재에 따른 신호 특성 분석)

  • Lee, Junsu;Chang, Jin Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.112-119
    • /
    • 2015
  • Photoacoustic microscopy is capable of providing high-resolution molecular images, and its spatial resolution is typically determined by ultrasonic transducers used to receive the photoacoustic signals. Therefore, ultrasonic transducers for photoacoustic microscopy (PAM) should have a high operating frequency, broad bandwidth, and high signal-reception efficiency. Polyvinylidene fluoride (PVDF) is a suitable material. To take full advantage of this material, the selection of the backing material is crucial, as it influences the center frequency and bandwidth of the transducer. Therefore, we experimentally determined the most suitable backing material among EPO-TEK 301, E-Solder 3022, and RTV. For this, three PVDF high-frequency single-element transducers were fabricated with each backing material. The center frequency and -6 dB bandwidth of each transducer were ascertained by a pulse-echo test. The spatial resolution of each transducer was examined using wire-target images. The experimental results indicated that EPO-TEK 301 is the most suitable backing material for a PAM transducer. This material provides the highest signal magnitude and a reasonable bandwidth because a large portion of the energy propagates toward the front medium, and the PVDF resonates in the half-wave mode.

Evaluation of Gestational Diabetes Mellitus Risk Factors Using Abdominal Subcutaneous Fat Thickness for Early Pregnancy in the US Imaging (초음파영상에서의 임신초기 복부피하지방두께를 이용한 임신성당뇨 위험인자 평가)

  • Kim, Changsoo;Yang, Sung-Hee;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.35-40
    • /
    • 2017
  • The purpose of this study was to investigate the relationship between abdominal subcutaneous fat thickness(ASFT) and maternal gestational diabetes mellitus(GDM) measured by ultrasound at period of pregnancy. We compared maternal age, pre-pregnancy body mass index, and weight gain during pregnancy in 286 pregnant women who were diagnosed with early pregnancy ASFT and high GDM screening test(50 g OGTT) of more than 140 mg/dL. ROC curve analysis was used to determine the cut-off value of ASFT for GDM prediction. Maternal age and weight gain during pregnancy were not related to GDM in the mid-trimester and pre-pregnancy body mass index and earely pregnancy ASFT were significantly different between normal and GDM high risk groups. The cut-off value of ASFT for GDM prediction was 2.23 cm(AUC 0.913. Sensitivity 76.19%, Specificity 93.72%). ASFT measured by ultrasound in early pregnancy was useful as an important index for predicting mid-trimester GDM prediction. Therefore, ASFT can be used as an auxiliary diagnostic index for early recognition of GDM.

The Usefulness of Fluorescein Angiography and Alternative Tests for Assessment of Fundus Hemorrhage (안저 출혈 시 형광안저혈관조영술 및 대체 검사의 유용성)

  • Yeon, Je-Jin;Koo, Bon-Kyeong;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.266-276
    • /
    • 2021
  • Fundus hemorrhage refers to abnormalities in the retinal tissue and blood vessels. Therefore, when a hemorrhagic change in the fundus occurs, the ophthalmologist orders various ophthalmic tests to evaluate the degree of hemorrhage and determine the progress of the lesion before, during, and after treatment to accordingly establish a treatment plan. Currently, the most useful and universal fundus examination includes optical coherence tomography (OCT), fundus photography (FP), and fluorescein angiography (FAG). Existing fluorescein angiography test methods for establishing a treatment plan for severe fundus bleeding have limitations. The authors propose that peripheral pupil and the 5-quadrant method should be performed using ultra-wide-angle fluorescence fundus angiography (UWFFA). Using this method, it is possible to quickly determine the area to be described, avoid the radius of bleeding as much as possible, and provide the ophthalmologist with a range of damaged tissue and abnormal blood vessels. Nevertheless, there are cases in which ophthalmologists judge that fundus bleeding is so severe that ultra-wide-angle fluorescence fundus angiography is meaningless. In such cases, ophthalmic ultrasound and electroretinogram may be used in that order as alternative methods of examination. Therefore, some clinical situations require the use of ophthalmic ultrasound and electroretinogram and should be performed accurately.

Differential Diagnosis of Benign and Malignant Thyroid Nodules Using the K-TIRADS Scoring System in Thyroid Ultrasound (갑상샘 초음파 검사에서 K-TIRADS 점수화 체계를 사용한 양성과 악성 갑상샘 결절의 감별진단)

  • An, Hyun;Im, In Cheol;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.201-207
    • /
    • 2019
  • This study has evaluated whether the method of using the combination of different risk group, according to K-TIRADS classification and K-TIRADS classification in thyroid ultrasonography is useful in a differential diagnosis of benign and malignant nodules. The subject was patients underwent thyroid ultrasonography and retrospective analysis were performed based on the results of fine needle aspiration cytology. A chi-square test was performed for the difference analysis of the score system in K-TIRADS and different risk group according to the benign and malignant of thyroid nodule. The optimized cut off value was determined by the K-TIRADS score and different risk group to predict malignant nodule through ROC curve analysis. In the differential verification result of K-TIRADS and different risk group, according to the classification of benign and malignant nodule group each showed significant difference statistically(p=.001). In the point classification according to K-TIRADS for the prediction of benign and malignant in ROC curve analysis showed AUC 0.786, Cut-off value>2(p=.001), and in the different risk group, it was decided as AUC 0.640, Cut-off value>2(p=.001). When discovering the nodule in thyroid ultrasound, it is considered that the K-TIRADAS which helps in identifying benign and malignant thyroid nodules, it is considered to be helpful in the differential diagnosis of thyroid nodules, than the classification system according to Different risk group, and when applying the classification system according to K-TIRADS, it is considered that it can reduce unnecessary fine needle aspiration cytology and could be helpful in finding the malignant nodules early.

Relationship of Bone Mineral Density Measured by Ultrasound Bone Densitometry and Body Composition or Backmuscle Strength (초음파방식으로 측정된 골밀도와 신체조성 및 배근력의 관계)

  • Lee, Won-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.721-728
    • /
    • 2019
  • The purpose of this study was to evaluate the relationship between bone mineral density (BMD) and body composition (BC) or backmuscle strength (BS). Sixty-one participants were measured by BMD using ultrasound bone densitometry and Inbody for BC (i.e., SLM=Soft lean mass, SMM=Skeletal muscle mass, FS=Fitness score. et al.), BS after self-questionnaire for life cycle. This study was performed after approving Institutional Review Board and obtaining the informed concent from all participants. Participants was divided into two group by BMD T-score; $T-score{\geq}-1.0$, T-score<-1.0. Statistical analysis was performed by using SPSS ver. 22.0(USA), Spearma test for correlation between BMD and BC or BS. BMD or SLM, BS was increased with increasing physical activity or body mass index. SMM or SMM, FS of BMD $T-score{\geq}-1.0$ group was higher than that of T-score <-1.0 group as well as BS(p>0.05). BMD T-score was correlated positively with SLM(r= 0.424) or SMM(r= 0.431) in men, as well as in women(p<0.05). BS was correlated positively with SLM or SMM, FS. BS was significantly positive correlated with BMD in women group (r= 0.591, p= 0.001), but not in men group. We concluded that BMD is the relationship with SLM or SMM, as well as BS in women.

The Value of Adding Ductography to Ultrasonography for the Evaluation of Pathologic Nipple Discharge in Women with Negative Mammography

  • Younjung Choi;Sun Mi Kim;Mijung Jang;Bo La Yun;Eunyoung Kang;Eun-Kyu Kim;So Yeon Park;Bohyoung Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.866-877
    • /
    • 2022
  • Objective: The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. Materials and Methods: From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23-75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of follow-up with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar's test or a generalized estimating equation. Results: In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). Conclusion: The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

Twelve-Month Volume Reduction Ratio Predicts Regrowth and Time to Regrowth in Thyroid Nodules Submitted to Laser Ablation: A 5-Year Follow-Up Retrospective Study

  • Roberto Negro;Gabriele Greco;Maurilio Deandrea;Matteo Rucco;Pierpaolo Trimboli
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.764-772
    • /
    • 2020
  • Objective: Laser ablation is a therapeutic modality used to reduce the volume of large benign thyroid nodules. Unsatisfactory reduction and regrowth are observed in some treated nodules. The aim of the study was to evaluate the long-term outcomes of laser treatment for solid nodules during a 5-year follow-up period, the regrowth rate, and the predictive risk factors of nodule regrowth. Materials and Methods: We retrospectively evaluated patients with benign, solid, cold thyroid nodules who underwent laser ablation and were followed-up for 5 years. According to the selection criteria, 104 patients were included (median baseline nodule volume, 12.5 mL [25.0-75.0%, 8-18 mL]; median energy delivered, 481.5 J/mL [25.0-75.0%, 370-620 J/mL]). Nodule volume, thyroid function test results, and ultrasound were evaluated at baseline and then annually after the procedure. Results: Of 104 patients, 31 patients (29.8%) had a 12-month volume reduction ratio (VRR) < 50.0% and 39 (37.5%) experienced nodule regrowth. Of these 39 patients, 17 (43.6%) underwent surgery and 14 (35.9%) underwent a second laser treatment. The rate of nodule regrowth was inversely related to the 12-month VRR, i.e., the lower the 12-month VRR, the higher the risk of regrowth (p < 0.001). The mean time for nodule regrowth was 33.5 ± 16.6 months. The 12-month VRR was directly related to time to regrowth, i.e., the lower the 12-month VRR, the shorter the time to regrowth (p < 0.001; R2 = 0.3516). Non-spongiform composition increased the risk of regrowth with an odds ratio of 4.3 (95% confidence interval [CI] 1.8-10.2; p < 0.001); 12-month VRR < 50.0% increased the risk of regrowth with an odds ratio of 11.7 (95% CI 4.2-32.2; p < 0.001). Conclusion: The VRR of thyroid nodules subjected to similar amounts of laser energy varies widely and depends on the nodule composition; non-spongiform nodules are reduced to a lesser extent and regrow more frequently than spongiform nodules. A 12-month VRR < 50.0% is a predictive risk factor for regrowth and correlates with the time to regrowth.

Guideliness of the Parameters Using Integrated Test in Down Syndrome Risk Prediction (다운증후군위험도 예측에서 통합선별검사를 이용한 파라미터의 유의성)

  • Lee, Jin-Won;Go, Sung-Jin;Kang, Se-Sik;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.549-555
    • /
    • 2016
  • This study was an evaluation of the significance of each parameter through aimed at pregnant women subjected to screening test(integrated test) in predicting risk of Down syndrome. We retrospectively analysed the correlation of risk of Down's syndrome with Nuchal Translucency(NT) images measured by ultrasound, Pregnancy Associated Plasma Protein A(PAPP-A), alpha-fetoprotein(AFP), unconjugated estriol(uE3), human chorionic gonadotrophin(hCG) and Inhibin A by maternal serum. As a result, a significant correlation with NT, uE3, hCG, Inhibin A is revealed with Down's syndrome risk(P<.001). In ROC analysis, AUC of Inhibin A is analysed as the biggest predictor of Down's syndrome(0.859). And the criterion for cut-off was inhibin A 1.4 MoM(sensitivity 81.8%, specificity 75.9%). In conclusion, Inhibin A was the most useful in parameters to predict Down's syndrome in the integrated test. If we make up for the weakness based on the cut-off value of parameters they will be able to be used as an independent indicator in the risk of Down's syndrome screening.

Vesicoureteral Reflux and Urinary Tract Infection in Children with Congenital Hydronephrosis (선천성수신증 환아에서 방광요관역류 및 요로감염 발생에 대한 고찰)

  • Kim, Jong-Ho;Kwak, Jae-Reyung;Park, Jee-Min;Pai, Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.222-228
    • /
    • 2009
  • Purpose : We checked voiding cystourethrography (VCUG) in patients with congenital hydronephrosis (CHN) and followed up the occurrence of urinary tract infection(UTI) in these patients. And we tried to figure out the relationship between CHN and VUR and UTI. Methods : We performed a retrospective study in 122 CHN patients who received VCUG from 2002 to 2008 at Ajou University Hospital. We executed logistic regression, chi-square test and T-test using version 16.0 SPSS package for the statistical analysis. P<0.05 was regarded as significant. Results : Most patients with CHN were male (73%) and there was a tendency of preferences for unilateral (77%) and left (84%) occurrence of hydronephrosis. The incidence of VUR was 18.9% among 122 CHN patients and no laterality difference was found to the severity of VUR or hydronephrosis. The incidences of VUR and UTI was higher in group of higher grade (III-IV) CHN patients, when compared to the lower group, respectively. When VUR was present in CHN patients, the incidence of UTI during infancy was also higher. Conclusion : The incidence of VUR was higher in patients with higher grades of CHN. The incidence of UTI during infancy was higher when VUR was present in the CHN patients.