• Title/Summary/Keyword: Ultrasound Test

Search Result 393, Processing Time 0.028 seconds

The Effect of Therapeutic Ultrasound and Static Stretching of the Hamstring Muscle on Flexibility and Static Balance Ability (초음파 치료와 정적 스트레칭이 뒤넙다리근의 유연성과 정적균형에 미치는 영향)

  • Cho, Seung-bong;Park, Mi-young;Won, Ji-sun;Kim, Ye-lin;Hong, Joon-taek;Kim, Seong-ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • Background: The purpose of present study was to examine the effect of ultrasound therapy and static stretching on hamstring length and balance. Design: Randomized Controlled Trial. Methods: A total of 30 adults in S college, Seongnam city, Gyeonggi-do, between the ages of 20-30 were randomly assigned to two groups. Group 1 (n=15) had ultrasound therapy, called US group. Group 2 (n=15) had static stretching, called SS group. Measurements were taken prior to starting the program and after completing the experiment using Finger to floor test and Active knee extension test to get the results of hamstring flexibility and the ability of static balance. Paired t-test was used to compare each group pre-test values to post-test values and to compare US post-test values to SS post-test values on PASW 18.0. Results: 1) Both hamstring SS group and US group had significant increase (p<.05) in Finger to floor test and Active knee extension test. 2) Dominant leg standing had significant change (p<.05) only in US group. 3) There was no significant difference between US group and SS group. Conclusion: Results showed that US group and SS group had an effect on changes in hamstring length (p<.05). However, they did not show a significant increase in static balance. Further effective studies on hamstring SS group and US group were needed based on this examination.

A Study for the Syndrome Differentiation of Retroverted Uterus Using Ultrasound (초음파 자궁형상진단을 이용한 자궁후굴증의 변증 진단 연구)

  • Hwang, Deok-Sang;Lee, Jae-Sung;Jeong, Eun-Jeong;Lee, Yoon-Jae;Lee, Kyung-Sub;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.3
    • /
    • pp.85-94
    • /
    • 2012
  • Objectives: We have studied the syndrome differentiation of ultrasound of retroverted uterus(RU) as the inspection in traditional Korean medicine. Methods: Eighty-four patients, who visited H clinic for infertility treatment, were recruited and evaluated by questionnaires and ultrasound, from April, 2012 to May, 2012. We used ultrasound(Logiq C3; GE Health care) for examination of RU. For statistics, we used Fisher's extract test to evaluate the RU and symptoms, and Chi-square test to evaluated the RU and syndrome differentiations, and Student T-test for the relationship between RU and each score of syndrome differentiation, using PASW Statistics(version 18.0.0) and GraphPad Prism(version 5.01). Results: 1. RU was correlated with moderate or severe dysmenorrhea and premenstrual lower abdominal pain. 2. In syndrome differentiation, blood stasis questionnaire was correlated with RU. 3. RU was related with dysmenorrhea, mass of low abdomen, pressure pain, clod of menstrual blood, dyspareunia. Conclusions: The ultrasound of RU might be related with the syndrome of blood stasis.

The Effect of Low-intensity Ultrasound (noblelife) on Pain Relief of Upper Trapezius (저강도 초음파치료기 노블라이프가 상부 승모근 통증에 미치는 영향)

  • Lee, Jao-On;Choi, Jong-Duk;Jung, Nak-Su;Choi, Kyu-Hwan
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • The purpose of this study was to investigate the effectiveness of the low-intensity ultrasound (noblelife) treatment on the pain points of upper trapezius muscle. The study recruited 20 patients who had trigger points in one side of the upper trapezius. The effectiveness of the low-intensity ultrasound treatment was assessed with subjective pain intensity using visual analog scale (VAS) and pressure pain threshold (PPT). The PPT was measured by pressure threshold algometer. Before and after the treatment, changes of pain were evaluated. Wilcoxon test for VAS data and paired t-test for PPT data were used for statistical significance. Compared to the pain intensity before the treatment, the pain intensity after treatment was significantly decreased (p<.05). Low-intensity ultrasound could be safely used in clinical application and at home for the treatment of patients with pain in upper trapezius muscle.

  • PDF

The Change of Pressure Pain Threshold of Myofascial Trigger Points by Ultrasound Application Method (초음파 적용방식에 따른 근-근막 발통점의 압통각 역치 변화)

  • Lee, Jeong-Woo;Yoon, Se-Won
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.2
    • /
    • pp.61-68
    • /
    • 2003
  • The purpose of this study was to compare the application method of ultrasound on the alteration of pressure pain threshold of myofascial trigger points. We used thirty patients with mayofascial pain syndrome in upper trapezius. Participants classified according to each group in non noxious dose, noxious dose by the ultrasound. The test was measured continuously pre test, post-test by algometer. The following results were obtained; 1. Pressure pain threshold were significantly increased in non-noxious dose and noxious dose group(p<.001). 2. In noxious dose group, pressure pain threshold were more significantly increased than non-noxious dose group(p<.001). These results lead us to the conclusion that non-noxious dose and noxious dose were significantly increased pressure pain threshold of upper trapezius trigger points. Therefore, a further direction of this study will be to provide more evidence that noxious dose have more effect on pressure pain threshold of myofascial trigger points.

  • PDF

Histologic evaluation of low-intensity pulsed ultrasound effects on bone regeneration in sinus lift

  • Kim, Sang-Hun;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.6
    • /
    • pp.271-275
    • /
    • 2010
  • Purpose: Many techniques have been described for achieving vertical augmentation of the maxillary sinus. The aim of this study is to evaluate the effect of low-intensity pulsed ultrasound (LIPUS) to enhance bone regeneration after sinus floor elevation. Methods: The sinus lifting technique was performed through a lateral approach on 8 different sites of 5 patients (3 males and 2 females) and their mean age was 45.7 years old. The sites were randomly assigned to the control or test groups. The control group had 4 sites that received lateral sinus lifting procedure only, while the test group had 4 sites that received LIPUS application after the lateral sinus lifting procedure. 24-32 weeks (an average of 29 weeks) postoperatively, new bone formation in the augmented sinus sites was evaluated through histologic and histomorphometric analyses of the biopsy specimens obtained during implant placement. Results: In the test group, the mean percentage of newly formed bone was $19.0{\pm}2.8$%. In the control group, the mean percentage of newly formed bone was $15.2{\pm}3.1$%. The percentage of newly formed bone was approximately 4% higher in those cases where the sinus was treated by LIPUS than the percentage in those cases where it was not used. The difference was statistically significant. Conclusions: Within the scope of this study, low-intensity pulsed ultrasound application after sinus lifting appeared to have a significant effect on the development of new bone formation.

Characterization of CFRP Laminates′Layups Using Through-Transmitting Ultrasound Waves

  • Im, Kwang-Hee;David K. Hsu;Cho, Young-Tae;Park, Jae-Woung;Sim, Jae-Ki;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.292-301
    • /
    • 2002
  • Ultrasound waves interact strongly with the orientation and sequence of the plies in a layup when propagating in the thickness direction of composite laminates. Also the layup orientation greatly influences its properties in a composite laminate. If the layup orientation of a ply is misaligned, it could result in the part being rejected and discarded. Now, most researchers cut a small coupon from the waste edge and use a microscope to optically verify the ply sequences on important parts. This may add a substantial cost to the production since the test is both labor intensive and performed after the part is cured. A nondestructive technique would be very beneficial, which could be used to test the part after curing and requires less time than the optical test. Therefore we have developed, reduced, and implemented a novel ply-by-ply vector decomposition model for composite laminates fabricated from unidirectional plies. This model decomposes the transmission of a linearly polarized ultrasound wave into orthogonal components through each ply of a laminate. High probability is found, by comparisons between the model and tests, in characterizing cured layups of the laminates by using the proposed method.

A Study on the Diagnostic Usefulness of Ultrasound and Magnetic Resonance Imaging for the Diagnosis of Shoulder Rotator Cuff Tear (어깨 회전근개 파열 진단을 위한 초음파 검사와 자기공명영상 검사의 진단적 유용성 연구)

  • Chae-Won, Kang;Hyo-Young, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.961-968
    • /
    • 2022
  • Rotator cuff tears are a leading cause of shoulder pain in adults. Due to the increase in social activities, the number of patients complaining of shoulder pain is increasing, and interest in shoulder diseases is also increasing. With the development of ultrasound equipment, the sensitivity and specificity of diagnosis are high, and it is used to diagnose rotator cuff tears in musculoskeletal disease. Ultrasound is recognized as a complementary method to MRI examination in rotator cuff tears. Therefore, this study aimed to find out the diagnostic usefulness of ultrasound and MRI examinations in the diagnosis of shoulder rotator cuff tears.A retrospective analysis was performed on 262 patients who were diagnosed with final rotator cuff damage by arthroscopy after completing ultrasound and MRI examinations. Sensitivity, feature, positive predictive value, image predictive value, and touch were disassembled for the test results. In addition, the degree of clavicular tear was scored and recorded in 5 stages. Ultrasound examination was similar to MRI examination results for both full-thickness and partial tears, and there was no statistically significant difference. Partial tear test results showed higher positive predictive value and accuracy than MRI test. In conclusion, ultrasound can be fully utilized as a screening test for rotator cuff disease, and it is thought that it will be selected and used clinically according to the patient's constitution and situation.

Effects of Ultrasound and Laser Therapy in Patients With Sub-Acute Lower Back Pain (초음파 치료와 레이저 치료가 아급성 요통에 미치는 영향)

  • Choi, Jin-Ho
    • Physical Therapy Korea
    • /
    • v.14 no.2
    • /
    • pp.76-84
    • /
    • 2007
  • This study was designed to determine the efficacy of ultrasound and laser therapy for sub-acute lower back pain. Twenty-seven patients with sub-acute low back pain were recruited, who were randomly assigned to three groups: Ultrasound group (actual ultrasound, 1.1 MHz, $1.0W/cm^2$, duty cycle 100%, 10 min/session, n=9), laser group (actual laser, 904 nm, 155 ns, 13.5 W, 12 mW, 90 sec/point, n=9), and control group (placebo ultrasound or placebo laser, n=9). All of treatments including placebo procedures were applied to patients over a period of 2 weeks, five times a week. Visual Analogue Scale (VAS), Modified Schober's Test (MST), and Modified Oswestry Disability Questionnaire (MODQ) were used by the clinical and functional evaluations before and after intervention. At post-hoc, significant differences were observed in all groups with respect to VAS, MST (p<.05), except MODQ. VAS and MST score were more significantly improved in the ultrasound group than the laser and control group (p<.0167). However, no significant difference was present between the laser group and the control group. Therefore, this study revealed that ultrasound therapy was effective in pain relief and improvement of lumbar mobility in patients with sub-acute lower back pain. However, laser therapy did not show the effects for sub-acute lower back pain.

  • PDF

Effects of Ultrasound on the Flexibility of the Waist after Stretching at the Erector Spinae in Normal Adults (척주세움근의 스트레칭 후 초음파 적용이 정상 성인의 허리 유연성에 미치는 영향)

  • Won-jye Choi
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.55-61
    • /
    • 2023
  • Background: The purpose of this study was to determine whether applying ultrasound after stretching the erector spinae muscle is an effective method for normal adults as a way to restore reduced back flexibility that causes back pain. Methods: The study was conducted on 60 healthy volunteers divided randomly into four groups (control group, stretching group, ultrasound group, ultrasound after stretching group). The flexibility-promoting effects were determined by assessing, each group, at the time of treatment, pre and post by modified fingertip to-floor (MFTF) and active straight leg raising (ASLR). The data were analyzed using the two-way ANOVA repeated measure with significant level α=.05. Results: Each group showed statistically significant changes in MFTF distance and ASLR degree. In the post-hoc test about this result, the length of MFTF and degree of ASLR in ultrasound after stretching group increased significantly compared to the others. Conclusion: The results suggest that using ultrasound after stretching is far more effective in increasing the flexibility of the erector spinae than using stretching or ultrasound intervention.

  • PDF

Clinical outcome of ultrasound-guided atelocollagen injection for patients with partial rotator cuff tear in an outpatient clinic: a preliminary study

  • Chae, Sang Hoon;Won, Jae Yeon;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.2
    • /
    • pp.80-85
    • /
    • 2020
  • Background: Atelocollagen has been studied for restoration of rotator cuff tendon. In this study, we attempted to evaluate the clinical outcome of ultrasound-guided atelocollagen injection in an outpatient clinic for patients with partial rotator cuff tear. Methods: We recruited 42 outpatients who visited our hospital from May 2019 to September 2019. Atelocollagen injection was performed in patients with partial rotator cuff tear diagnosed by magnetic resonance imaging and ultrasound. American Shoulder and Elbow Surgeons (ASES), Constant, Korean Shoulder Score (KSS) and Simple Shoulder Test (SST) scores, and range of motion were assessed before injection and after 2 months. Statistically, we analyzed the clinical results using the Wilcoxon signed-rank test. Results: Finally, 15 patients were enrolled for analysis. There was no significant difference between pre- and post-injection in terms of range of motion, ASES (57.0 vs. 60.4), Constant (56.4 vs. 58.9), KSS (64.6 vs. 68.5), and pain-visual analog scale (4.2 vs. 3.7), except function-visual analog scale (F-VAS; 6.3 vs. 7.1) and SST (6.6 vs. 6.9). A significant difference was found in SST (P=0.046) and F-VAS (P=0.009). According to the ultrasound results at 2 months, we found hyperechoic materials in three of seven patients. The most common complication of atelocollagen injection was post-injection pain (53%, 8/15). Conclusions: Ultrasound-guided atelocollagen injection for partial rotator cuff tear showed no significant change in terms of clinical outcomes, except for F-vas and SST score. Tendon regeneration was not clear due to the remnants of atelocollagen present at 2-month follow-up ultrasound. There seems to be alarming post-injection pain for 2 to 3 days in the patients who received atelocollagen injection in an outpatient clinic.