• Title/Summary/Keyword: Ultrasound Test

Search Result 398, Processing Time 0.033 seconds

Investigation on the Effect of Stress Waves on Soil Flushing (토양세척에 있어서 탄성파의 효과에 관한 연구)

  • 김영욱;김지형;이인모
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.37-40
    • /
    • 2000
  • Acoustically enhanced soil flushing method is a newly developed in-situ remediation technique. However, there has not been an analytical method that can be used to evaluate the effectiveness of ultrasonic wave under different conditions. This study was undertaken to investigate the degree of enhancement in contaminant removal due to ultrasonic energy on the soil flushing method. The test conditions included different levels of ultrasonic power and hydraulic gradient. The test soils were Ottawa sand, a fine aggregate, and a natural soil, and the surrogate contaminant was a Crisco Vegetable Oil. The test results showed that sonication could increase contaminant removal significantly. Increasing sonication power increased pollutant removal. The faster the flow is, the smaller the degree of enhancement will be. The pollutants in dense soils are more difficult to be removed than in loose soils.

  • PDF

A Defect Detection of Thin Welded Plate using an Ultrasonic Infrared Imaging (초음파 열화상 검사를 이용한 박판 용접시편의 결함 검출)

  • Cho, Jai-Wan;Chung, Chin-Man;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1060-1066
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material efficiently. In this paper a detection of the welding defect of thin SUS 304 plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (20kHz) ultrasonic transducer was used to infuse the welded thin SUS 304 plates with a short pulse of sound for 280ms. The ultrasonic source has a maximum power of 2kW. The surface temperature of the area under inspection is imaged by a thermal infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the defect tip and heated up highly, are observed. From the sequence of the thermosonic images, the location of defective or inhomogeneous regions in the welded thin SUS 304 plates can be detected easily.

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.

Optimization of Ascorbic Acid Extraction from Rugosa Rose (Rosa rugosa Thunb.) Fruit Using Response Surface Methodology and Validation of the Analytical Method

  • UM, Min;KIM, Ji-Woo;LEE, Jae-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.364-375
    • /
    • 2020
  • In this study, ultrasound-assisted extraction was performed to extract ascorbic acid from rugosa rose (Rosa rugosa Thunb.) fruit. The optimal conditions were investigated by response surface methodology, using two variable including reaction time (16-44 min) and temperature (16-44℃). The ascorbic acid extraction was sensitive to the reaction time rather than the reaction temperature, and the optimal conditions for ascorbic acid extraction were 25℃ and 30 min. Ascorbic acid and gallic acid in the rugosa rose fruit extract were completely separated by HPLC, with a resolution factor of over 1.5 between the two. The correlation coefficient of the ascorbic acid was 0.999 in a linearity test for 50-150 ㎍/mL concentration of extract. The limit of detection and limit of quantification values were 0.16 ㎍/mL and 29.89 ㎍/mL, respectively. The relative standard deviations (RSD) for repeatability and reproducibility were determined, and each RSD showed good precision at less than 5% (N=6).

Reliability Evaluation of a Motor Core Applied Ultrasound Infrared Thermography Technique (초음파 적외선열화상 기법을 적용한 모터 코어의 신뢰성 평가)

  • Jung, Yoon-Soo;Roh, Chi-Sung;Lee, Gyung-Il;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.60-66
    • /
    • 2016
  • This study used an ultrasound infrared thermography technique to detect issues in the motor core of typical power equipment. The current defect inspection method of the motor core is often incomplete (due to the limits of visual inspection) and thus the reliability of the motor core is reduced. Therefore, in this study, experiments were carried out to increase the reliability of the test by using an ultrasonic infrared thermal non-destructive inspection method to image the motor core. The ambient temperature of the experimental system was maintained at $25^{\circ}C$. Experiments were carried out to examine a damaged motor core and a defect-free motor core. Experimental results confirm the technique clearly detected defects in the motor core, thereby confirming the possibility of using this technique in the field.

Ultrasound-guided epidural block in axial spondyloarthritis patients with limited spine mobility: a randomized controlled trial

  • Elsaman, AM;Hamed, A;Radwan, AR
    • The Korean Journal of Pain
    • /
    • v.34 no.1
    • /
    • pp.114-123
    • /
    • 2021
  • Background: Evaluation of the effectiveness of caudal epidural injection on pain, spine mobility, disease activity, and activity of daily living in axial spondyloarthritis (SpA) patients. Methods: A total sample of 47 patients were registered in this study. They were randomly assigned into 2 groups; Group I received caudal epidural injections, ultrasound-guided, with 1% lidocaine hydrochloride mixed with triamcinolone, whereas Group II did not receive any injections. All participants fulfilled the ASAS criteria for axial SpA. Outcome measures were as follows: visual analogue scale, Oswestry disability index (ODI), modified Schober test, lateral lumbar flexion, and Ankylosing Spondylitis Disease Activity Score (ASDAS) with assessment at baseline, 2 weeks, and 8 weeks post-treatment. This clinical trial was registered on clinicaltrials.gov under the number NCT04143165. Results: There was a significant difference between both groups regarding pain, ODI, spine mobility and ASDAS scores in favor of group I. This effect was at its maximum after 2 weeks. Despite the decline of this effect after 2 months, the difference between the groups remained significant. Higher disease activity, younger age, and shorter disease duration were associated with better outcomes. Conclusions: Epidural injection of lidocaine and triamcinolone is a cost effective and a practical technique for controlling pain, as well as improving the function of the spine and disease activity scores in axial SpA patients with acceptable complications and relatively sustained effect.

Analysis of the Accuracy about Abdominal Ultrasonography and Clinical Chemical Test with Fatty Liver Patients on the Medical Examination (종합검진 후 지방간 환자의 복부 초음파 검사와 임상화학적 검사결과의 정확성 분석)

  • Kim, Young-Jae;Song, Jong-Nam;Kim, Min-Eui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.183-189
    • /
    • 2012
  • Ultrasonography is one of the fields on the imaging studies within intra-abdominal organs. A blood test is a typical method of clinical chemical examination on the in vivo test of clinical symptoms. Fatty liver is performed simultaneously two kinds of diagnostics methods, intra-abdominal ultrasound and blood tests. At an implementing this, the standard of blood tests value was the TBIL, TC, AST, ALT, ALP, GGT, TG, HDL-C, GLU. In this study analyzing the accuracy of the two kinds of test, ultrasonography and blood test, on patients with fatty liver. From January to March 2012, patients 459 determined fatty liver within 1350, who received health examination simultaneously on the intra-abdominal ultrasonography and blood tests. Same result of ultrasonography and blood test's patients were 459 ie, 60.8%. and different result of those examinations was 280 ie, 39.2%. Consequently diagnostic accuracy was 60.8%. It presumably caused by differences in the diagnostic performance of ultrasound professionals(Radiologist or Radiological Technologist). In order to overcome this, ongoing educational and study will be needed.

Comparison of Abductor Hallucis Contractility between Regular and Flat Feet during SFE with SLSKB Test

  • Moon, Dong-Chul;Jung, Ju-Hyeon
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.409-416
    • /
    • 2022
  • Purpose: This study compared and analyzed the contractility of the abductor hallucis (AbdH), an intrinsic foot muscle, between flat feet and normal feet during a movement control test (single-leg small knee band test) using ultrasonography. Methods: A total of 23 subjects with (n = 11) and without (n = 12) flatfoot were included in the study. Each subject performed the short foot exercises (SFE) with a single-leg small knee bend (SLSKB) test, which is a functional movement. An ultrasound device was used to collect data regarding the changes in the contractility of the AbdH. Results: Intergroup comparison showed that dorsoplantar thickness was significantly reduced at baseline and during the SFE with SLSKB in the flatfoot group (p < 0.05). Intragroup comparison showed that the cross-sectional area significantly improved when the SFE was performed with SLSKB in the control group (p < 0.05). Conclusion: In this study, it was observed that the AbdH had inadequate contractility during the SLSKB test in subjects with flatfoot; therefore, it is important to train the contraction of the AbdH via functional movements during clinical interventions for subjects with flatfoot.

Morphological Changes in Quadriceps Muscles through 3-Week Combined Exercise using a Wearable Robot (EX1) in Young Adult

  • Jang-hoon Shin;Naeun Byeon;Heeju Yu;DaeEun Kim;Byungmun Kang;Dongwoo Kim;Hwang-jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.1
    • /
    • pp.33-42
    • /
    • 2023
  • Objective: This study aims to analyze the effect of regular exercise through the combined walking-oriented aerobic and resistance exercises using EX1 in young adults. Design: Experimental one group pre and post test Methods: Participants comprised17 healthy young adults. All subjects performed a combined exercise program for 10 times using EX1. We measured quadriceps muscle thickness using ultrasound. Additionally, the hand grip strength test, and sit and reach test were performed before and after the exercise. Through paired t-test, we investigated whether there was a statistically significant difference in the measurement results after exercise program. Results: The rectus femoris muscle contraction ratio showed significant difference after exercise(P< 0.01). In the sit and reach test, flexibility showed significant difference after exercise(P < 0.01). The hand grip strength test also showed significant difference after exercise(P < 0.05). Conclusions: Healthy young adults can effectively perform various exercises commonly performed in daily life using EX1.

Image Evaluation and Association Analysis of the Cardiovascular Disease of the Degree of Pancreatic Steatosis in Ultrasonography

  • Cho, Jin-Young;Ye, Soo-Young;Ko, Seong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • Increasing fat tissue of obese people, increases the rate of cardiovascular disease, diabetes, metabolic syndromes and dyslipidemia. An increase in the focal tissue of pancreas is a known risk factor of these diseases. Although there exists sufficient research on the diagnosis and treatment of pancreatic cancer, studies have been done on fatty pancreas. In this study, based on ultrasound imaging and using a texture characteristic of GLCM, fatty pancreas was divided into three categories: mild, moderate and severe. We compared and analyzed the three groups was by Pancreatic ultrasonography and body characteristics, serological tests, pressure and the degree of arteriosclerosis, against normal control group. The following parameters of control and test groups were measured: WC (waist circumference),BMI (body mass index), TC (total cholesterol), TG (triglyceride), HDL-C (High-density lipoprotein cholesterol) and LDL-C (Low-density lipoprotein cholesterol), SBP (systolic blood pressure), BST (Blood Sugar Test) and aortic PWV (pulse wave velocity). We observed the values correspondingly increasing fat deposition. However, ABI (Ankle Brachial pressure index) stenosis and HDL-C levels decreased with increasing fat deposit (p <0.05); a drop in these parameters are known to be harmful to the human body. The difference in texture characteristics between normal control group and pancreatic fatty group (mild, moderate, and severe) was statistically confirmed. Ultrasound imaging of pancreatic steatosis categorized the disease as mild, moderate and severe based on the characteristic texture. In conclusion, we observed on increase in metabolic syndrome, dyslipidemia, and arteriosclerosis, proportional to the degree of pancreatic fat deposition. The escalation of these diseases was confirmed and was directly related with predictors of cardiovascular diseases.