• Title/Summary/Keyword: Ultrasound Scan

Search Result 133, Processing Time 0.024 seconds

PSNR Analysis of Ultrasound Images for Follow-up of Hepatocellular Carcinoma (간세포암 추적관찰 초음파영상의 PSNR 분석)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.263-267
    • /
    • 2015
  • In this paper, a method was proposed for objective and scientific judgment on disease conditions that is currently relied on subjective judgment of ultrasound practitioners. In the proposed method, mean squared errors (MSE) in ultrasound images for follow-up of HCC patients were obtained and the Peak Signal to Noise Ratio(PSNR) of the ultrasound images was analyzed. According to the results of analysis, MSE and PSNR values changed over time. This is attributable to changes in ultrasound images resulting from increases in utrasonic echoes following the progression of HCC. The results of the present study can be used as a method for scientific and objective judgment in ultrasonic scan instead of current subjective judgment by practitioners.

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

A Follow-up Study of DMSA Renal Scan in Children with . Acute Pyelonephritis and Vesicoureteral Reflux (급성신우신염과 방광요관역류 환아에서 DMSA신주사의 추적관찰)

  • Oh, Chang-Hee;Choi, Won-Kyoo;Kim, Ji-Hong;Lee, Jae-Seung;Kim, Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.145-151
    • /
    • 1998
  • Purpose : DMSA renal scan is known as a valuable method for evaluating acute pyelonephritis and renal scar in patients with febrile urinary tract infection or vesicoureteral reflux. We made this study, to determine the most effective use of DMSA renal scan. Methods : 155 children were admitted to the Pediatric Department of Yonsei University, Severance hospital with the symptom of urinary tract infection from January, 1992 to June, 1995. DMSA scan, renal ultrasound and VCUG were performed. One consisted of 29 patients with the diagnosis of acute pyelonephritis without vesicoureteral reflux and the otherconsistedofllpatientswithvesicoureteralreflux. Results : The follow-up DMSA scans at mean $0.99{\pm}0.46$ months after the initial DMSA scans were performed in the 29 children with acute pyetonephritis. 21($72.4\%$) of 29 children showed normal DMSA scans. 8 children with abnormal DMSA scans had follow-up DMSA scans at 2.5 months after the initial scans and 6 of 8 children showed normal DMSA scans. Only 12($41.4\%$) of 29 children showed abnormal renal ultrasound. The data about DMSA scans in 32 children with vesicoureteral reflux showed that there were abnormal DMSA scans in Grade $I;25.0\%$, Grade $II;44.5\%$, Grade $III;64.3\%$, Grade $IV;92.9\%$ and Grade $V;100.0\%$. There was a significant difference in that 36 renal unit ($68.0\%$) on DMSA renal scan and 26 renal units ($49.1\%$) on renal ultrasound showed abnormal finding(P<0.05). Conclusion : DMSA renal scan is more useful than renal ultrasound for the diagnosis of acute pyelonephritis. It is considered that if the initial DMSA scan is abnormal, a follow-up DMSA scan must be performed after 10weeks (8-12weeks) and the change in DMSA scan evaluated.

  • PDF

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

Interference Effect within the Cyst by Ultrasound in the Renal Ultrasonography (초음파검사에서 콩팥 낭종 내의 간섭효과)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.111-115
    • /
    • 2014
  • In this study, I proposed of an engineering analysis methods due to interference effect within the cyst by ultrasound in the renal ultrasonography. Experimental results, the human can not be found to distinguish interference caused by the ultrasonic echoes within the cyst. The proposed method is used, then in the cyst appears insignificant signal can distinguish the difference. Thus, the misdiagnosis can be prevented in advance.

Prenatal diagnosis of 5p deletion syndrome: A case series report

  • Han, You Jung;Kwak, Dong Wook
    • Journal of Genetic Medicine
    • /
    • v.14 no.1
    • /
    • pp.34-37
    • /
    • 2017
  • 5p deletion syndrome, also known as Cri-du-Chat syndrome, is a chromosomal abnormality caused by a deletion in the short arm of chromosome 5. Clinical features of 5p deletion syndrome are difficult to identify prenatally by ultrasound examination, thus most cases of 5p deletion syndrome have been diagnosed postnatally. Here, we report eight cases of 5p deletion syndrome diagnosed prenatally, but were unable to find common prenatal ultrasound findings among these cases. However, we found that several cases of 5p deletion syndrome were confirmed prenatally when karyotyping was performed on the basis of abnormal findings in a prenatal ultrasound scan. Hence, it is necessary to carefully perform prenatal ultrasonography for detection of rarer chromosomal abnormalities as well as common aneuploidy.

Survey on Usage of Korean Quantitative Ultrasound for Proposing Quantitative Ultrasound Quality Control Guideline (초음파골밀도측정기 정도관리 방안제시를 위한 한국 초음파골밀도 사용현황 조사)

  • Jeong, Yoon-Ji;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.329-337
    • /
    • 2018
  • This study was investigated quantitative ultrasound (QUS) usage in Korea for the QUS quality control guidelines. A total of 344 questionnaires collected from July 24th to August 25th 2017 were analyzed. Questionnaires were created through user interviews, expert group advice, literature review and field observation. As a result of the general characteristics of quantitative ultrasound holding amounted to 81.98% of clinic and 6.69% of hospitals. The main user was radio-logical technologists as 31.39%. The contact methods of the gel pad (balloon) were the most used at 56.68% and the scan region was 91.9% of calcaneus. The quantitative ultrasound quality control cycle was 67.37% when the abnormality was found in the equipment, and 63.66% when the accuracy control was implemented according to the manual. The phantoms of QUS were 34.30% of the manufacturer's own phantoms. User of QUS had never received education for quality control of quantitative ultrasound as 62.20%. This study was expected to be useful when creating detailed quality control guidelines in the future, as well as guidelines for the quality control of Korea's standard quantitative ultrasound.

Ultrasonic Backward Radiation on Randomly Rough Surface (무작위로 거친 표면에서의 후방복사 초음파)

  • Kwon, Sung-D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • The angular dependence(profile) of backward radiated ultrasound was measured for glass specimens with random surface roughness using ultrasonic goniometer that ran changes the incident angle continuously. It was concluded that the roughened region had greater acoustic impedance than the unperturbed region. The comparison of backward radiations showed that the amplitude of peak and the area of radiation profile were increased with surface roughness. It was suggested from the sensitive dependence of the profile area that the profile of backward radiation could be applied to in the nondestructive evaluation of sulfate region. Inclined C-scan technique with the transducer inclined at Rayleigh angle showed the reverse of luminosity and the high signal to noise ratio so that it provided high resolution.

A recursive scheme for improvement of the lateral resolution in B-scan ultrasonography (회귀방법에 의한 초음파 진단기의 측면해상도 개선에 관한 연구)

  • 김선일;민병구;고명삼
    • 전기의세계
    • /
    • v.31 no.3
    • /
    • pp.204-208
    • /
    • 1982
  • The objective of this paper is to present a digital method for improving the lateral resolution of the B-scan images in the medical applications of ultrasound. The method is based upon a mathematical model of the lateral blurring caused by the finite beam width of the transducers. This model provides a simple method of applying a recursive scheme for image restoration with fast computation time. The point spread function (P.S.F.) can be measured by the reflective signals after scanning the small pins located along the depth of interest. From the measured P.S.F., one can compute the coefficient matrices of the inverse discrete-time dynamic state variable equation of the blurring process. Then, a recursive scheme for deblurring is applied to the recorded B-scan to improve the lateral resolution. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

Ultrasound Synthetic Aperture Beamformer Architecture Based on the Simultaneous Multi-scanning Approach (동시 다중 주사 방식의 초음파 합성구경 빔포머 구조)

  • Lee, Yu-Hwa;Kim, Seung-Soo;Ahn, Young-Bok;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.803-810
    • /
    • 2007
  • Although synthetic aperture focusing techniques can improve the spatial resolution of ultrasound imaging, they have not been employed in a commercial product because they require a real-time N-channel beamformer with a tremendously increased hardware complexity for simultaneous beamforming along M multiple lines. In this paper, a hardware-efficient beamformer architecture for synthetic aperture focusing is presented. In contrast to the straightforward design using NM delay calculators, the proposed method utilizes only M delay calculators by sharing the same values among the focusing delays which should be calculated at the same time between the N channels for all imaging points along the M scan lines. In general, synthetic aperture beamforming requires M 2-port memories. In the proposed beamformer, the input data for each channel is first upsampled with a 4-fold interpolator and each polyphase component of the interpolator output is stored into a 2-port memory separately, requiring 4M 2-port memories for each channel. By properly limiting the area formed with the synthetic aperture focusing, the input memory buffer can be implemented with only 4 2-port memories and one short multi-port memory.