• Title/Summary/Keyword: Ultrasound Measures

Search Result 72, Processing Time 0.022 seconds

A study on ultrasound analysis of the transformer strange signal (변압기 이상음의 초음파 분석에 관한 연구)

  • 백화종;지석근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.835-838
    • /
    • 2002
  • A running high voltage equipments produce ultrasonic wave that has unique sound by the specific characteristics of the electricity. The generation of the ultrasonic wave is made by the electric transform like arcing, corona, and tracking so on. The mechanical losses and fatal human damages are happened by the electric failure of high voltage equipments. To prevent and diagnose the obstacle factors of the high voltage equipments, the measurement of the ultrasonic wave became to be prominent. However standardized data have been a deficient situation by now. This paper measures the ultrasonic wave coming from the real running transformer equipments and transforms it as an audio frequency. Measured data represents as frequency and time domain through the FFT(Fast Fourier Transform) transform. In conclusion, the purpose of this paper is to standardize the analyzed data.

  • PDF

Influence of Slashpipe Exercise on Symmetrical Contraction of Trunk Muscle in Normal Adults

  • Choi, Young In;Kim, Jung Sun;Kim, Shin Young
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.5
    • /
    • pp.298-303
    • /
    • 2019
  • Purpose: This study examined the effects of slashpipe exercise on reducing the thickness of the left and right external oblique, internal oblique, transverse abdominis, erector spinae, and multifidus muscles. Methods: A total of 29 healthy adult men and women were included in the study. They performed trunk flexion in the supine position and trunk extension in the prone position with a slashpipe and weight bar. The external oblique, internal oblique, and transverse abdominis muscles were measured in the supine position, while the erector spinae and multifidus muscles were measured in the prone position. The data were analyzed using the SPSS ver 21.0 statistical program. The difference in thickness between the right and left sides of the trunk muscle was analyzed by repeated measures analysis. The statistical significance level was set to p<0.05. Results: The results showed that the slashpipe exercise reduced significantly the difference in thickness of the oblique internus and erector spinae muscles compared to the weight bar exercise. Conclusion: The chaotic fluidity of the fluid filled inside the slashpipe could be used as sensory feedback information on body mal-alignment, which would have positively affected the symmetrical contraction of the trunk muscles as a trigger for self-correction. Therefore, it will have a useful effect not only on the health of the general public, but also on low back patients and athletes with muscle asymmetry.

Effects of the PNF Stabilization Technique for the Hip Joint and the Bridging Exercise on the Trunk Stabilizer Muscles in Healthy Adults (고관절에 적용한 PNF 안정화 기법과 교각운동이 요부안정화 근육에 미치는 영향)

  • Kim, Yong-Hun;Jung, Ju-Hyeon
    • PNF and Movement
    • /
    • v.15 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the effects of the PNF stabilization technique for the hip joint and the bridging exercise on the trunk stabilizer muscles in healthy adults. Methods: Twenty-eight healthy adults were randomly allocated to either a PNF stabilization exercise group (n = 12) or a bridging exercise group (n = 16). The outcome measures included the contraction thickness ratio in the transversus abdominis (TrA), internal oblique (IO), and external oblique (EO), and the TrA lateral slide was assessed during the abdominal drawing-in maneuver using b-mode ultrasound. The researcher measured the abdominal muscle thickness of each participant before the therapist began the intervention and at the moment that the intervention was applied. Between-group comparisons were performed using the Mann-Whitney U test. The level of statistical significance was set at 0.05. Results: The PNF intervention program showed a significant increase in the trunk stabilizer muscle. The percentage of change in the TrA thickness showed a significant interaction between intervention. However, there were no significant differences in the IO and EO between the two groups. Conclusion: The PNF stabilization technique for the hip joint can be used effectively to improve the IO and TrA muscles in healthy adults.

Relationship between Muscle Sizes from Ultrasound Images and Endurance Time with/without Experience of Low Back Pain : Pattern of Recruiting Trunk Muscles (요통경험 유무에 따른 초음파 영상에서 측정된 근육크기와 근지구력 시간과의 관계: 유지 시간에 따라 동원된 체간근육 특성)

  • Kim, Hye-Yeon;Kim, So-Yeon;Lee, Hae-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.235-243
    • /
    • 2011
  • The purpose of the study was to examine the thickness of the trunk muscles ie. external obliques (EO), transversus abdominis (TrA), and multifidus and the trunk endurance strength in order to determine any relationship between the presence or absence of low back pain (LBP) and the size of trunk muscles. Data were obtained from 50 subjects, aged between 19-29 years. Participants had no experience of spinal problems that had resulted in a restriction of normal activity or time-off work and no current spinal symptoms. Measurements of muscle thickness of the trunk muscles were collected at rest, contraction and 15 seconds of post contraction during endurance strength tests. Background information was obtained followed all physical measures. Subjects were divided into two groups based on their experience of LBP. In draw-in maneuver, increasing the thickness of TrA was observed in all participants while EO was decreased at contraction in group 1 and increase in group 2. Only subjects in the group 2 had TrA increased during the flexion endurance test. In the side-bridge endurance test, the thickness of the right TrA was also observed differently between groups. Therefore, the results of the study may suggest that a function of specific muscle should be addressed for training persons with LBP.

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

Comparison of Relative Thickness of the Iliotibial Band Following Four Self-Stretching Exercises

  • Kim, Hyun-Sook;Yoon, Tae-Lim
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.24-31
    • /
    • 2012
  • The aim of this study was to investigate the effectiveness of self-stretching exercises for iliotibial band (ITB) (Side-lying; right hip and knee were flexed to support the pelvis while left hip was extended and adducted, Standing A; side-bending of the trunk on standing with crossed leg, Standing B; same as Standing A, except the hands were clasped overhead and shifted right side, and Standing C; same as Standing B, except moving the arms diagonally downward) to help determine the most effective self-stretching method to stretch ITB. Twenty-one healthy subjects who do not have ITB shortness from Yonsei University (14 men and 7 women) between the ages of 18 to 28 years voluntarily participated. Ultrasound was performed to measure the thickness of the ITB between the long axis of the ITB and the level parallel to the lateral femoral epicondyle during four self-stretching exercises. All data were found to approximate a normal distribution. We used a one-way repeated-measures analysis of variance (ANOVA) to compare the thickness of the ITB among all self-stretching exercises. The level of significance was set at ${\alpha}$=.05. The ANOVA was followed by Bonferroni's correction. The overall mean of ITB thickness was $1.14{\pm}.4$ mm (${\pm}$ standard deviation) in resting status. The change in the ITB thickness in percentages between the tested position of each self-stretching exercises and resting status was significant (p<.05) (Side-lying $26.62{\pm}10.18%$ with 95% confidence interval [CI]=21.99~31.25%; Standing A $29.46{\pm}16.19%$ with 95% CI=22.09~36.84%; Standing B $44.06{\pm}14.82%$ with 95% CI=37.31~50.81%; Standing C $53.76{\pm}12.1%$ with 95% CI=48.25~59.29%). Results indicated significant differences among four self-stretching exercises except Side-lying versus Standing A (p<.01). Based on these findings, the Standing C self-stretching exercise was the most effective in stretching the ITB thickness among four types of ITB self-stretching exercises. Additionally, the Side-lying self-stretching exercise using gravity to stretch the ITB is recommended as a low-load (low-intensity), long-duration stretch.

The Effect of Application of a Non-Elastic Fixation Belt on the Balance Ability and Fall Prevention in Elderly Women (비탄력 고정식 벨트가 노인 여성의 균형능력과 낙상예방에 미치는 영향)

  • Lee, Jang-Tae;Chon, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.398-404
    • /
    • 2017
  • The aim of this study was to determine the effect of a non-elastic fixation belt on the balance ability and fall prevention in elderly women. Elderly women experience reduced balance ability and an increased risk of falls due to a weakening of the surrounding sacroiliac joint and pelvic muscles during childbirth and menopause. On the other hand, specific studies are still needed. The subjects were allocated randomly to two groups: control (n=20) and experimental (n=20). The experimental group used a non-elastic fixation belt, whereas the control group had no fixation belt. The balance ability and the fall index were measured in all subjects using a balance measurement device, and the low abdominal muscle thickness was determined in the experimental group using ultrasound imaging for the exact application of the non-elastic fixation belt. The following statistical analysis was performed: an independent t-test for the general characteristics of the subjects, $2{\times}2$ analysis of variance with repeated measures for the balance and fall index score, and a paired t-test for the abdominal muscle thickness. The group ${\times}$ time interaction effect showed significant improvement in the General Stability Index (F1,38=47.24, p=0.001), Fourier Harmony Index (F1,38=88.83, p=0.001), Weight Distribution Index (F1,38=50.21, p=0.001), and Fall Index (F1,38=21.59, p=0.001). The thicknesses of the transverse abdominal (p=0.001) and internal oblique (p=0.001) muscles were increased significantly in the experimental group after using the non-elastic fixation belt. Overall, the application of a non-elastic fixation belt could be effective in improving the balance ability and fall prevention in elderly women.

Altered Motor Control in Patients With Neck Pain and Prospective Research Work (경부통증 환자의 변형된 운동조절 특성 분석과 향후 활용 방안)

  • Lee, Min-young;Yoon, Bum-chul
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.20-34
    • /
    • 2016
  • Background: It is necessary to find and develop the effective way of intervention for patients with neck pain, since the neck pain is becoming increasingly common throughout the world. To identify the altered motor control in patient with neck pain would be informative to find and develop the effective way of intervention. Objects: The aim of this study was to review literature regarding the altered motor control in patients with neck pain, measured by using surface electromyography (sEMG), ultrasonography, and functional magnetic resonance imaging (fMRI), and to suggest prospective research work on neck pain. Methods: Case-control (neck pain/healthy) studies published between 2004 and 2015 that investigated neck muscle activation, thickness, cross-sectional area, and fat infiltrate were searched in Scopus, PubMed, and ScienceDirect. Twenty-eight articles were included in this study. Results: sEMG, ultrasonography, and fMRI were used complementarily to investigate the altered superficial and deep neck muscle activation, thickness, cross-sectional area, and fat infiltrate in patients with neck pain. They showed the following altered motor control when compared retrospectively with healthy subjects or during specific functional tasks: (1) increased superficial muscle activation, (2) lesser deep muscle thickness, (3) smaller cross-sectional area of the deep muscle, and (4) greater fat infiltrate in deep muscles. In particular, among the women, the office workers showed higher muscle activation of superficial neck muscles during functional tasks, although they did not have neck pain, than those who were not office workers. Conclusion: Studies revealed that patients with neck pain showed an altered motor control when compared with healthy subjects by using various assessment modalities. Understanding this phenomenon would help researchers design an effective intervention for alleviating neck pain or to evaluate the effectiveness of the intervention. In addition, we recommend that female office workers take measures to care for their necks before developing neck pain.

Effects of Fast Treadmill Training on Spinal Alignment and Muscles Thickness

  • Kim, Won-Gi;Kim, Yong-Seong;Kim, Yong-Beom;Jeong, Ho-Jin;Kim, Jae-Woon;Cho, Woon-Su
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.4
    • /
    • pp.175-180
    • /
    • 2017
  • Purpose: This study examined the effects of fast walking training on a treadmill on the spinal alignment and muscle thickness of normal adults. Methods: A total of 36 college students in their twenties participated in the study for eight weeks, and they were divided into the normal walking, fast walking, and speed change groups. All the groups were measured in a pre-test before training. The subjects performed exercise three times per week for six weeks. A post-test was conducted six weeks after training began, and a follow-up test was done two weeks after the training ended.Trunk and pelvic tilts were measured in Formetric 4D for the spinal alignment of the subjects. The muscle thickness was examined in the trunk with an ultrasound test. Repeated-measures ANOVA was conducted to test the main effects and interactions among the measurement variables according to time and group. Results: Significant differences were observed in the pelvic tilt according to time. There were significant differences in the external oblique, internal oblique, transverse abdominal muscle according to time. The post-test results showed significant differences in the left external oblique, internal oblique muscles between before training, six weeks into training, and two weeks after the completion of training. There were significant interactions in the left oblique muscles according to the time and group. Conclusion: These findings have some value for patient rehabilitation and clinical applications and interventions through walking training.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.