• 제목/요약/키워드: Ultrasound Intensity

검색결과 222건 처리시간 0.026초

Feasibility Study of Improved Patch Group Prior Based Denoising (PGPD) Technique with Medical Ultrasound Imaging System

  • Kim, Seung Hun;Seo, Kanghyen;Kang, Seong Hyeon;Kim, Jong Hun;Choi, Won Ho;Lee, Youngjin
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.55-59
    • /
    • 2017
  • The purpose of this study was to quantitatively evaluate image quality using intensity profile, coefficient of variation (COV), and peak signal to noise ratio (PSNR) with respect to noise reduction techniques in the ultrasound images. For that purpose, we compared with the median filter, Rudin-Osher-Fatemi (ROF), Anscombe and proposed patch group prior based denoising (PGPD) techniques. To evaluate image quality, the Shepp-Logan phantom and the ultrasound image were acquired using simulation and experiment, respectively. According to the results, the difference of intensity profile using PGPD technique is lowest compared with original Shepp-Logan phantom. In simulation, the measured COV was 0.249, 0.198, 0.198, 0.177, and 0.080 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Also, in experimental image, the measured COV was 0.245, 0.230, 0.231, 0.242 and 0.187 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Especially, when we used PGPD technique, the PSNR has highest value in both simulation and experiment. In this study, we performed simulation and experiment study to compare various denoising techniques in the ultrasound image. We can expect the PGPD technique to improve in medical diagnosis with excellent noise reduction.

저강도 초음파의 관절염 치료 적용성 평가 (An Evaluation of Low Intensity Ultrasonic Characteristics for Arthritis Healing)

  • 홍성민;한승무
    • 대한기계학회논문집A
    • /
    • 제29권6호
    • /
    • pp.787-794
    • /
    • 2005
  • Nowadays chronic degenerative diseases such as arthritis are increasing rapidly, even though acute infectious diseases are decreasing due to the advance of modern medicine. Although many of remedies are developed for arthritis healing, there is no precise medical prescription, and pathogenesis is not examined exactly. In this study, we confirmed gene expression of BMP 1A, BMP 2B, osteonectin and MGP which are genes related with bone formation in osteoblast by using ultrasonic stimulation. Through this study, we also evaluated the fact that ultrasound could be applied to arthritis healing by making activated osteoblast induce remodeling of cartilage. As a result of this research, BMP 2B and MGP have higher rates of expression in specific ultrasound mode. In conclusion, it is expected that ultrasound could be used efficiently for healing arthritis if we use ultrasounds according to symptoms of arthritis on reasonable terms.

Properties of Low-Molecular Alginate by Ultrasound

  • Kim Sang-Moo;Park Seong-Min;Lee Keun-Tae;Bae Tae-Jin
    • Fisheries and Aquatic Sciences
    • /
    • 제2권2호
    • /
    • pp.149-154
    • /
    • 1999
  • Response Surface Methodology was applied for optimizing the processing parameters of ultrasound treatment in order to produce low-molecular alginate. The use of ultrasound significantly reduced viscosity of alginate solutions. Suggested parameters of ultrasound treatment for maximum reduction of alginate molecular weight were: specific intensity, 115.81 $W/cm^2$ at 20kHz frequency; treatment time, 35.55 min; temperature, $20.08^{\circ}C$; alginate concentration, $2.5\%$. Low-molecular alginate obtained by ultrasound had two peaks on Sepharose CL-6B gel filtration. The viscosities of control, fraction I, and fraction II at $0.1\%$ concentration and $25^{\circ}C$ were 3.07, 1.23, and 0.82cps, respectively. Molecular weights of control, fraction I, and fraction II alginates were 336,500, 70,400, and 52,800 daltons, and their solubilities were 3, 6, and $14\%$, respectively. The lower molecular weight of alginate, the lower the alcohol precipitation and the higher $Ca^{2+}$ ion binding capacities. Heavy metal ion binding capacities of alginates were high in the following order of Pb, Cd, Zn, and Co.

  • PDF

자외선 조사로 유발된 피부 염증성 반응에 맥동성 초음파가 미치는 영향 (The Effect of Pulsed Ultrasound on Skin Inflammatory Reaction Induced by Ultraviolet Irradiation)

  • 이정우;박수지;윤세원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권4호
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: This study aims to examine the effects of pulsed ultrasound on skin inflammatory reaction induced by ultraviolet irradiation. Methods: Twenty subjects were selected for this study. Inflammatory reaction was induced by ultraviolet irradiation in two areas of the lumbar region of the subjects. Pulsed ultrasound (3 MHz) was applied to one of the two areas of inflammatory reaction at a pulse ratio of 1:4, intensity of $0.5W/cm^2$, once a day for 5 min, and pulsed ultrasound was not applied to the other area. Wound color (chromatic red), luminance (gray) and wound contraction (area) were measured using digital imaging processing method. Results: There was a significant difference in wound color (chromatic red) in the interaction between time and area. There was a significant difference in luminance in the interaction between time and area. There was a significant difference in wound contraction between the two areas. Conclusion: These results indicate that pulsed ultrasound increased the wound contraction rate and reduced the inflammatory reaction activity such as erythema induced by ultraviolet irradiation.

500KHz 초음파를 이용한 Lidocaine HCl Gel의 경피투과 효과 (Transdermal Permeation Effects of Lidocaine HCl Gel Using Low Frequency Ultrasound of 500kHz)

  • 정대인;윤세원;최석주;이정우;김명훈;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제18권1호
    • /
    • pp.75-82
    • /
    • 2006
  • Purpose: This study conducted the following experiment to examine transdermal permeation effects or 500 KHz ultrasound with lidocaine HCl. Methods; First, to experiment skin permeation enhancement effects of 500 KHz ultrasound frequency, it produced apparatus and transducer of 500 KHz ultrasound and Franz diffusion cell for skim permenation experiment suitable to purposes of the experiment. Transdermal permeation experiment applied Lidocaine HCL gel to skin of hairless mouse depending on ultrasound frequency and duty cycle and analyzed permeation ratio with HPLC. Results: As a result of fixing lidocaine HCl gel at the same intensity with pulsed mode and continuous mode and comparing transdermal permeation ratio by frequency, transdermal permeation ratio was increased at 500 KHz ultrasound and remarkably increased at continuous ultrasound. It was found that 1 MHz and 500 KHz ultrasound in transdermal permeation experiment enhanced transdermal permeation of lidocaine HCl. In particular, transdermal permeation of 500 KHz using lidocaine HCl gel was highest. Conclusion: However, researches considering various frequencies, intensities and application hours in low frequency areas including 500 KHz ultrasound are needed to increase deep permeation or drugs.

  • PDF

Effects of High-Intensity Ultrasound & Supercritical Nitrogen on PP-MA Reactive Extrusion

  • Sohn, Chang-Hee;Shim, Dong-Chul;Lee, Jae-Wook
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.369-369
    • /
    • 2006
  • Compatibilizers contribute to many processes in polymer industry, such as manufacturing polymer blends and composites. They are usually designed to be block or graft form which is combined in polar and non-polar parts in the first synthesis process level, for example, the general form of maleic anhydride (MA) as a compatiblizer is a grafted counterpart. However, the process of making the compatibilizer is related to the first synthesis level and it has some problems, such as high cost, poor processability, limitation on use and properties, and so on. So, in order to improve its poor processability and overcome the limitation on use, we developed compatibilizers which have various chemical forms by high intensity ultrasound and super critical fluid nitrogen in polymer melt reactive extrusion.

  • PDF

초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구 (A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity)

  • 김성민;이만표;최병철;최상혁;배하석;정회승;박성윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

고강도 초음파에 의한 PEO의 분해특성에 관한 연구 (Effect of High Intensity Ultrasonic Wave on the Degradation Characteristics of PEO)

  • 김형수;김미화
    • 폴리머
    • /
    • 제26권3호
    • /
    • pp.353-359
    • /
    • 2002
  • 본 연구에서는 고강도 초음파를 이용하여 분자량이 다른 poly(ethylene oxide) (PEO)를 증류수에 분산시켜 초음파 가진(加振) 시간이 PEO의 성질에 미치는 영향을 조사하였다. 고강도 초음파는 PEO 수용액 상에서 동공 형성 및 파괴를 일으켜서 PEO 거대 라디칼을 형성하였으며 이로인하여 PEO 자체의 유변학적 성질, 화학 구조 그리고 용융 거동이 현저하게 변화되었다. 초음파 가진에 의하여 PEO의 용융 점도는 감소되었고, 물과 PEO 사슬에서 비롯된 여러 종류의 라디칼들의 상호 작용으로 말미암아 새로운 말단기들이 생성되었다. 아울러 분자량에 따라 상이한 용융 거동을 나타내었는데, 상대적으로 분자량이 큰 경우에는 가진되지 않은 PEO에 비하여 결정화 속도가 느려지고 용융 피크의 강도가 감소되는 특성을 나타내었다.

운동과 MWM을 혼합한 중재(EMWM)가 어깨관절 충돌증후군 환자의 AHD, ROM, 기능수행정도에 미치는 효과 (Effects of Mobilization with Movement Combined with Exercise(EMWM) on ADH, ROM and Functional Performance in Patients with Impingement Syndrome of the Shoulder)

  • 추연기
    • 대한통합의학회지
    • /
    • 제7권2호
    • /
    • pp.153-163
    • /
    • 2019
  • Purpose : This study was to identify the effects of Mobilization with Movement combined with exercise (EMWM) on acromio-humeral distance (AHD), range of motion (ROM), pain intensity, and functional performance in patients with impingement syndrome of the shoulder. Methods : The subjects were 40 patients diagnosed with impingement syndrome of the shoulder. Twenty subjects are randomly assigned to each 2 different groups; Group 1. (exercise group), Group 2. (EMWM group). Three weekly interventions were given for 4 weeks. The main outcome measures were ultrasound, goniometer, visual analogue scale (VAS), and Korean Constant shoulder score (K-CSS). The ultrasound (AHD), ROM (flexion, abduction), pain intensity (for shoulder flexion) and functional performance (K-CSS) were compared between the groups. Results : The AHD was significantly increased in Group 2 compared to Groups 1. No significant difference was observed between the groups in the range of abduction of the shoulder, but the range of flexion was significantly increased in Group 2 compared to Groups 1. Pain intensity was significantly lower in Group 2 than in Group 1, and functional performance was significantly increased in Group 2 compared to Group 1. Conclusion : An intervention that combined mobilization with movement with exercise was more effective than exercise alone for rapid recovery from shoulder injury and improvement in functional performance.