Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

  • Kim, Do-Youn;Cho, Youn-Ho;Lee, Joon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.546-551
    • /
    • 2010
  • The objective of this research is to estimate the crack location and size of a carbon steel pipe by using a laser ultrasound guided wave for the wall thinning evaluation of an elbow. The wall thinning of the carbon steel pipe is one of the most serious problems in nuclear power plants, especially the wall thinning of the carbon steel elbow caused by Flow-Accelerated Corrosion (FAC). Therefore, a non-destructive inspection method of elbow is essential for the nuclear power plants to operate safely. The specimens used in this study were carbon steel elbows, which represented the main elements of real nuclear power plants. The shape of the wall thinning was an oval with a width of 120mm, a length of 80mm, and a depth of 5mm. The L(0,1) and L(0,2) modes variation of the ultrasound guided wave signal is obtained from the response of the laser generation/air-coupled detection ultrasonic hybrid system represent the characteristics of the defect. The trends of these characteristics and signal processing were used to estimate the size and location of wall thinning.

The medium coupling effect on propagation of guided waves in engineering structures and human bone phantoms

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li
    • Coupled systems mechanics
    • /
    • v.1 no.4
    • /
    • pp.297-309
    • /
    • 2012
  • As a result of the medium coupling, propagation characteristics of ultrasonic waves guided by a multi-phase medium can be different from those in a homogeneous system. This phenomenon becomes prominent for a medium consisting of phases with considerably distinct material and physical properties (e.g., submerged structures or human bones covered with soft tissues). In this study, the coupling effect arising from both fluid and soft tissues on wave propagation in engineering structures and human bone phantoms, respectively, was explored and calibrated quantitatively, with a purpose of enhancing the precision of ultrasonic-wave-based non-destructive evaluation (NDE) and clinical quantitative ultrasound (QUS). Calibration results were used to rectify conventional NDE during evaluation of corrosion in a submerged aluminium plate, and QUS during prediction of simulated healing status of a mimicked bone fracture. The results demonstrated that with the coupling effect being appropriately taken into account, the precision of NDE and QUS could be improved.

Chronic Intractable Calcific Lateral Epicondylopathy Treated with Ultrasound-Guided Barbotage Combined with Extracorporeal Shock-Wave Therapy (석회성 외측 상과병증의 초음파 유도 하 세척흡인술과 체외충격파치료의 병행)

  • Kim, Kun-Woo;Yoon, Kyung Jae;Do, Jong Geol;Hwang, Jin-Tae;Lee, Yong-Taek
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.138-141
    • /
    • 2019
  • Lateral epicondylopathy represents pain in the lateral (radial aspect) of the elbow caused by degeneration in the common extensor tendon. Calcium deposit frequently developes in lateral epicondylopathy, with the prevalence up to 46%. There are considerable debates on its treatment protocols for lateral epicondylopathy so far, likewise, the effective treatment method for calcific lateral epicondylopathy has not been established. We report here a case of chronic intractable calcific lateral epicondylopathy treated with ultrasound-guided barbotage and focused type extracorporeal shock wave therapy (ESWT). To our knowledge, this is the first report of calcific lateral epicondylopathy treated by ultrasound-guided barbotage combined with ESWT.

Ultrasound-guided Exact Focusing of Extracorporeal Shock Wave Therapy for the Calcific Tendinitis of Gluteus Medius - A Case Report - (중둔건 석회화 건염의 초음파 유도하 정확한 조준에 의한 체외충격파치료 -증례 보고-)

  • Moon, Sang Ho;Lee, Song;Kim, Kwang Hai;Jeong, Jongpil;Hong, Seong Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.94-98
    • /
    • 2012
  • Calcific tendinitis is characterized by inflammation around calcium hydroxyapatite crystal deposits. Minimally invasive extracorporeal shock wave therapy (ESWT) has been postulated to be an effective treatment option for treating calcific tendinitis. In clinical practice, shock waves usually are aimed at the painful area after palpation and not focused. It has been known that exact fluoroscopic focusing of ESWT at the calcific deposit for treatment of calcifying tendinopathy is highly effective. Ultrasound is a simple, inexpensive and radiation-free diagnostic tool that has been used to demonstrate tendinopathy including calcific tendinitis. However, focusing of shock wave under ultrasound is less well established. We present a patient in whom large calcific tendinitis of gluteus medius was completely resolved by exact focusing of ESWT by ultrasound with literature review.

  • PDF

Evaluation of Composite Laminates for Aircraft Primary-Structure Applications Using Non-Linear Parameter of Ultrasonic Guided Wave (유도초음파의 비선형 파라미터를 이용한 항공기 구조체의 복합재료 적층판 열화 평가)

  • Cho, Youn-Ho;Kim, Do-Youn;Choi, Heung-Soap;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.126-131
    • /
    • 2010
  • The purpose of this study is to assess the condition of composites used in aircraft under varying temperature environment with ultrasound guided wave technique. Investigation of crucial influential factor on the composite health monitoring related to aircraft operational environments such as the number of thermal cycles and temperature deviation between ground level and flight altitude has been of a great concern for aircraft safety issue. In this study, ultrasonic guided wave health monitoring scheme is proposed to evaluate composite specimens damaged with the thermal fatigue simulating aircraft operational condition. Guided wave dispersion curves are used to select right modes which show a promising sensitivity to each different thermal fatigue damage level. The present approach can be also implemented as one of on-lines health monitoring tools for aircraft.

A Study on Propagation of Guided Waves in a Steam Generator Tube (증기발생기 세관에서의 유도초음파 전파에 관한 연구)

  • 송성진;박준수;김재희;김준영;김영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.353-361
    • /
    • 2004
  • Propagation of the guided waves in a steam generator (SG) tube was investigated. Dispersion curves and the incident angles corresponding to the specific modes were calculated for the SG tube. The modes of guided wave were identified by time-frequency diagrams obtained by short time Fourier transform. Group velocities were also determined from the time-frequency diagrams obtained at the different separations of transducers. In experiment. distinct mode conversion was not observed when the guided ultrasound passed curved region of the S/G tube. The optimum mode of guided wave for the inspection of SG tube was suggested and verified by experiments.

Non-Contact Guided Wave Technique with Enhanced Mode-Selectivity (모드 선택성을 강화한 비접촉식 유도초음파 기술)

  • Kim, Hyun-Mook;Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.597-602
    • /
    • 2004
  • In practical applications of guided wave techniques, it is very important but also difficult to identify the propagating modes, and it is preferred to generate and detect a single or less dispersive mode. Also the noncontact method is required in the automated field application. So this paper considers a non-contact guided wave technique with enhanced mode-selectivity, where a laser beam illuminated through arrayed line slits is used as the transmitter and the air-coupled transducer is used as the receiver. The line arrayed laser illumination is a wavelength matching technique that ran generate only a few modes. The air-coupled transducer detects the leaky wave of the propagated guided wave, and by tuning its detection angle we ran detect the selected single mode. Experimental results for a 1mm thick aluminum plate proved the usefulness of the proposed method, and especially it was shown that this method was powerful in the generation and detection of the $a_0$ mode.

Exploring and calibrating local curvature effect of cortical bone for quantitative ultrasound (QUS)

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li;Ta, De-An
    • Structural Engineering and Mechanics
    • /
    • v.48 no.4
    • /
    • pp.501-518
    • /
    • 2013
  • Apart from thinning of cortical layers, the local bone curvature, varying along bone periphery, modulates ultrasound waves as well, which is however often underestimated or overlooked in clinical quantitative ultrasound (QUS). A dedicated three-dimensional finite element modelling technique for cortical bones was established, for quantitatively exploring and calibrating the effect of local curvature of cortical bone on ultrasound. Using a correlation-based mode extraction technique, high-velocity group (HVG) and low-velocity group (LVG) wave modes in a human radius were examined. Experimental verification using acrylic cylinders and in vitro testing using a porcine femur were accomplished. Results coherently unravelled the cortical curvature exerts evident influence on bone-guided ultrasound when RoC/${\lambda}$ <1 for HVG mode and RoC/${\lambda}$ <2 for LVG mode (RoC/${\lambda}$: the ratio of local bone curvature radius to wavelength); the sensitivity of LVG mode to bone curvature is higher than HVG mode. It has also been demonstrated the local group velocity of an HVG or LVG mode at a particular skeletal site is equivalent to the velocity when propagating in a uniform cylinder having an outer radius identical to the radius of curvature at that site. This study provides a rule of thumb to compensate for the effect of bone curvature in QUS.

Ultrasound-guided Extracorporeal Shock Wave Therapy Combined with Multiple Needling for Calcific Tendinitis in Shoulder (견관절의 석회화 건염에 대한 초음파 유도하 다발성 천공술 및 고에너지 체외 충격파 병합치료)

  • Jung, Tae Wan;Song, Dong Ik;Lee, Soon Hyuck;Jeoung, Woong Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: To evaluate the effectiveness of ultrasonography-guided combined multiple needling and high-energy extracorporeal shock wave therapy (ESWT) for calcific tendinitis of the shoulder. Materials and Methods: We included 42 calcific tendinitis patients who underwent ultrasonograpy-guided multiple needling followed by high-energy ESWT who visited the clinic from January 2010 to June 2013. The average follow up period was 45 weeks. Clinical evaluation was done before and after 12 weeks from treatment, in clinical terms using pain visual analogue scale (P-VAS), ASES, UCLA scores reflecting performance and symptom improvement, and in sonographic terms by studying the changes in size of the calcific nodules. Results: A statistically significant improvement was seen in P-VAS, ASES, UCLA scores and decreased calcification size on sonographic evaluation. Conclusion: Ultrasonography-guided combined multiple needling and high-energy ESWT is considered as a useful method which could provide clinical function improvement and reduction of calcification deposit.

  • PDF