• Title/Summary/Keyword: Ultrasound Follow Up

Search Result 180, Processing Time 0.035 seconds

Efficacy of Lauromacrogol Injection for Ablation of Benign Predominantly Cystic Thyroid Nodules and Related Factors: A Prospective Study

  • Yi Jie Dong;Zhen Hua Liu;Jian Qiao Zhou;Wei Wei Zhan
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.479-487
    • /
    • 2022
  • Objective: To prospectively evaluate the efficacy of lauromacrogol injection for ablation (LIA) of benign predominantly cystic thyroid nodules and its related factors. Materials and Methods: A total of 142 benign predominantly cystic thyroid nodules (median volume, 12.5 mL; range, 0.4-156 mL) in 137 patients (male:female sex ratio, 36:101; mean age ± standard deviation [SD], 49 ± 13 years) were treated with LIA after being confirmed as benign via cytology. The volume reduction rate (VRR) of the nodules and cosmetic score were evaluated during follow-up at 1, 3, and 6 months after treatment and every 6 months thereafter. A VRR of ≥ 50% at the 12-month follow-up was considered to indicate effective treatment. The associations between the clinical factors and nodular ultrasound features, including the initial nodule volume, proportion of solid components, vascularity grade and ineffective treatment (VRR of < 50% at the 12-month follow-up), and regrowth were analyzed. Results: All patients completed follow-up for at least 12 months. The average ± SD follow-up period was 32 ± 11 months (range, 12-54 months). The effective treatment rate was 73.2% (104/142), while the regrowth rate was 12.0% (17/142) at the last follow-up. Grade 2-3 intranodular vascularity in the solid components of the nodules was the only independent factor associated with ineffective treatment, with an odds ratio (reference category, grade 0-1) of 3.054 (95% confidence interval, 1.148-8.127) (p = 0.025). Conclusion: LIA is an effective treatment for predominantly cystic thyroid nodules. Grade 2-3 intranodular vascularity in the solid components of nodules is the only independent risk factor for ineffective LIA.

Ultrasound-Guided Injection Therapy for Elbow, Wrist, and Hand Pain (팔꿈치, 팔목, 손 통증의 초음파 유도하 주사치료)

  • Ahn, Jaeki
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.59-69
    • /
    • 2021
  • Patients with pain, numbness, and weakness in their elbows, wrists, and hands often need proper rehabilitation treatments. Among them, musculoskeletal injection therapy should be performed after a full evaluation of the patient, taking into account history and physical examination leading to clinical diagnosis. General rules such as accurate diagnosis and injection materials selection are used to achieve maximum benefit with minimal side effects. During injection, patient location, aseptic care, penetration techniques, follow-up and follow-up care must be maintained. Specific techniques may vary depending on the type, lesion, and location of the injection therapy. For optimal effectiveness, physician should inject directly into the lesion and avoid the injection of surroundings as much as possible. Therefore, ultrasound-guided injections are needed to accurately inject. These conditions and other conditions of the hands, wrists, and elbows can be effectively diagnosed and treated with diagnostic ultrasound and ultrasound-guided injections.

PSNR Analysis of Ultrasound Images for Follow-up of Hepatocellular Carcinoma (간세포암 추적관찰 초음파영상의 PSNR 분석)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.263-267
    • /
    • 2015
  • In this paper, a method was proposed for objective and scientific judgment on disease conditions that is currently relied on subjective judgment of ultrasound practitioners. In the proposed method, mean squared errors (MSE) in ultrasound images for follow-up of HCC patients were obtained and the Peak Signal to Noise Ratio(PSNR) of the ultrasound images was analyzed. According to the results of analysis, MSE and PSNR values changed over time. This is attributable to changes in ultrasound images resulting from increases in utrasonic echoes following the progression of HCC. The results of the present study can be used as a method for scientific and objective judgment in ultrasonic scan instead of current subjective judgment by practitioners.

Follow-Up Intervals for Breast Imaging Reporting and Data System Category 3 Lesions on Screening Ultrasound in Screening and Tertiary Referral Centers

  • Sun Huh;Hee Jung Suh;Eun-Kyung Kim;Min Jung Kim;Jung Hyun Yoon;Vivian Youngjean Park;Hee Jung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1027-1035
    • /
    • 2020
  • Objective: To assess the appropriate follow-up interval, and rate and timepoint of cancer detection in women with Breast Imaging Reporting and Data System (BI-RADS) 3 lesions on screening ultrasonography (US) according to the type of institution. Materials and Methods: A total of 1451 asymptomatic women who had negative or benign findings on screening mammogram, BI-RADS 3 assessment on screening US, and at least 6 months of follow-up were included. The median follow-up interval was 30.8 months (range, 6.8-52.9 months). The cancer detection rate, cancer detection timepoint, risk factors, and clinicopathological characteristics were compared between the screening and tertiary centers. Nominal variables were compared using the chi-square or Fisher's exact test and continuous variables were compared using the independent t test or Mann-Whitney U test. Results: In 1451 women, 19 cancers (1.3%) were detected; two (0.1%) were diagnosed at 6 months and 17 (1.2%) were diagnosed after 12.3 months. The malignancy rates were both 1.3% in the screening (9 of 699) and tertiary (10 of 752) centers. In the screening center, all nine cancers were invasive cancers and diagnosed after 12.3 months. In the tertiary center, two were ductal carcinomas in situ and eight were invasive cancers. Two of the invasive cancers were diagnosed at 6 months and the remaining eight cancers newly developed after 13.1 months. Conclusion: One-year follow-up rather than 6-month follow-up may be suitable for BI-RADS 3 lesions on screening US found in screening centers. However, more caution is needed regarding similar findings in tertiary centers where 6-month follow-up may be more appropriate.

Effects of steroid injection during rehabilitation after arthroscopic rotator cuff repair

  • Ha, Joong-Won;Kim, Hyunkyo;Kim, Seong Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.166-171
    • /
    • 2021
  • Background: This study aims to compare the clinical outcomes of steroid injections during the rehabilitation period after arthroscopic rotator cuff repair (ACRC). Methods: Among patients who underwent ARCR, 117 patients who met the inclusion and exclusion criteria were enrolled. Pain and range of motion (ROM) recovery at the 3-, 6-, and 24-month follow-up visits and functional outcome at the 24-month follow-up were compared between 45 patients who received ultrasound-guided subacromial steroid injection at postoperative week 4 or 6 and 72 patients who did not. Functional outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) score and Constant score. Healing of the repaired tendon and retear were observed at the 6-month follow-up via magnetic resonance imaging (MRI) or computed tomography (CT) arthrography. Results: At the 3-month follow-up, the steroid injection group showed lower visual analog scale scores than the control group (p<0.05) and showed faster recovery of forward flexion and internal rotation (p<0.05). From the 6-month follow-up, the two groups did not show differences in pain and ROM, and the ASES score and Constant score also did not significantly differ at the 24-month follow-up. The two groups did not differ in retear rate as determined by MRI or CT arthrography at the 6-month follow-up. Conclusions: This study demonstrated that ultrasound-guided subacromial steroid injection at 4 or 6 weeks after ARCR leads to quick pain reduction and ROM recovery until 3 months after surgery. Therefore, subacromial steroid injection is speculated to be an effective and relatively safe method to assist rehabilitation.

Incidental double duct sign: Should we be worried? Results from a long-term follow-up study

  • Lu Yao;Hoda Amar;Somaiah Aroori
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 2024
  • Backgrounds/Aims: Double duct sign (DDS) (dilated common bile and pancreatic duct) is synonymous with pancreatic head/peri-ampullary tumor (PHPAT). There is limited evidence on whether incidental DDS (I-DDS) is associated with an increased risk of malignancy. This study aimed to evaluate 5-year outcomes of I-DDS. Methods: Patients were categorized according to their risk of malignancy. 'Low-risk' patients, including those with I-DDS between 2010 and 2015, were analyzed in this study. The primary outcome was incidence of PHPAT within five years of identification of DDS. Histology results from endoscopic ultrasound-guided biopsy were considered diagnostic. Secondary outcomes were incidence of benign causes, extent of follow-up investigations, and clinical indicators of malignancy in patients with DDS. Results: Among 103 patients with DDS, 20 had I-DDS. Subsequent follow-up of these 20 patients found no patient with PHPAT, two (10%) patients with chronic pancreatitis, and 18 (90%) patients with no cause found. The median follow-up duration for 'low-risk' patients was 7.3 years (range, 6-11 years). The mean number of follow-up investigations per patient was two (range, 0-9). Investigations included computed tomography (n = 27), magnetic resonance cholangiopancreatography (n = 23), endoscopy (n = 16), and ultrasound (n = 14). Patients with jaundice were more likely to have malignancy (p < 0.01). Those with abdominal pain were more likely to have a benign cause (p < 0.01). Hyperbilirubinemia and/or deranged liver enzymes and raised CA19-9 were more likely to be associated with PHPAT (p < 0.01). Conclusions: Patients with I-DDS have a low risk of developing PHPAT within five years.

Carotid duplex ultrasound: interpretations and clinical applications

  • Choi, Hye-Yeon
    • Annals of Clinical Neurophysiology
    • /
    • v.23 no.2
    • /
    • pp.82-91
    • /
    • 2021
  • Carotid duplex ultrasound is commonly used to diagnose various carotid artery diseases due to it being noninvasive and easy to perform. Carotid atherosclerosis is a major indicator for the need to perform carotid duplex ultrasound, which can determine the degree of stenosis, plaque characteristics, and intima-media thickness. It can also be used to screen and follow-up after carotid revascularization. Here we discuss the standard techniques, interpretations, and clinical indicators for carotid duplex ultrasounds.

The Clinical Usefulness of Ultrasound-Aided Fixation Using an Absorbable Plate System in Patients with Zygomatico-Maxillary Fracture

  • Lee, Jong Hun;Park, Jun Hyung
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.330-334
    • /
    • 2013
  • Background Ultrasound-aided fixation is a recently developed alternative method of treatment of zygomatico-maxillary (ZM) fracture, and it can resolve the problems of excessive torsion force and subsequent fractures of screws. We conducted this study to evaluate the clinical usefulness of ultrasound-aided fixation as compared with the conventional fixation method using a drill and an expander in patients with ZM fracture. Methods We conducted a retrospective study in 35 patients with ZM fracture who had been treated at our hospital during a period ranging from March of 2008 to December of 2010. We divided them into two groups: an ultrasound-aided fixation group, comprising 13 patients who underwent ultrasound-aided fixation (SonicWeld Rx, KLS Martin), and a conventional group, comprising 22 patients who underwent conventional fixation (Biosorb FX, Linvatec Biomaterials Ltd.). We compared such variables as sex, direction, age at operation, follow-up period, operation duration, number of fixed holes, and time to discharge between the two groups. Results The ultrasound-aided fixation reduced the operation duration by about 30 minutes as compared with that of conventional fixation. There was no significant difference in follow-up period, number of fixed holes, or time to discharge between the two groups. Furthermore, there were no complications in either group. Conclusions The ultrasound-aided fixation of fractured ZM bone using an absorbable implant system is safe and effective in promptly reducing the bone fracture and providing satisfactory cosmetic outcomes over time.

Guidance of Nerve Stimulator and Ultrasound for Transforaminal Epidural Steroid Injection in Lumbosacral Radicular Pain : A Single Institution Experience in Vietnam

  • Viet-Thang Le;Chi Hue Nguyen;Phuoc Trong Do;Anh Minh Nguyen;Khoi Hong Vo
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.2
    • /
    • pp.194-201
    • /
    • 2024
  • Objective : This study aimed to evaluate the clinical feasibility of the combination of ultrasound and nerve stimulator guidance in transforaminal epidural steroid injections (TESIs) to manage lumbosacral chronic radicular pain. Methods : Using the combination of nerve stimulator and ultrasound guidance, TESIs were performed in 125 segments of 78 patients who presented with chronic lumbar radicular pain. Demographic characteristics and surgical outcomes were recorded on admission, pre-procedural and post-procedural for 1-week, 1-month, 3-month, and 6-month follow-ups. The result was measured using the Numeric rating scale (NRS) and Oswestry disability index (ODI). Results : Patients who received TESIs showed significant improvements on two evaluation tools (NRS, ODI), compared to that before procedure (p<0.001). No significant complications were observed for 6 months' follow-up. Conclusion : The result suggests that a combination of ultrasound and nerve stimulator guidance in transforaminal epidural injections is safe, reliable and effective for short-term management of lumbar disc herniation. It is a promising technique and has shown good results in providing intermediate pain relief.